1、 GD/J 1162020 Technical requirements and measurement methods for wavelength divison multiplexing system equipment -GD/J 1162020 I .II 1 .1 2 .1 3 .1 4 .2 4.1 N10Gbit/s DWDM.2 4.2 N100Gbit/s DWDM.3 4.3 .4 5 .6 6 .7 6.1 10Gbit/s.7 6.2 100Gbit/s.8 7 OTU.8 7.1 OTU.8 7.2 OTU.9 7.3 .9 8 .9 8.1 .9 8.2 .10
2、9 .10 10 .10 11 /.11 12 .11 13 .11 13.1 .11 13.2 OTU.14 13.3 .17 13.4 .21 13.5 .21 13.6 /.23 13.7 .24 .25 GD/J 1162020 II GB/T 1.12009 GD/J 1162020 1 1 10Gbit/s100Gbit/s50GHz100GHz 2 YD/T 19602009 N10Gbit/sWDM YD/T 30702016 N100Gbit/sWDM YD/T 33912018 WDM ITU-T G.691 STM-64SDHOptical interfaces for
3、single channel STM64 and other SDH systems with optical amplifiers ITU-T G.692 Optical interfaces for multichannel systems with optical amplifiers ITU-T G.693 Optical interfaces for intra-office systems ITU-T G.957 Optical interfaces for equipments and systems relating to the synchronous digital hie
4、rarchy ITU-T G.959.1 Optical transport network physical layer interfaces IEEE 802.3ba 3CSMA/CD4:40Gb/s100Gb/sInformation technology-Telecommunications and information exchange between systems-Local and metropolitan area networks-Specific requirements Part 3:Carrier Sense Multiple Access with Collisi
5、on Detection(CSMA/CD)Access Method and Physical Layer Specifications Amendment 4:Media Access Control Parameters,Physical Layers and Management Parameters for 40 Gb/s and 100 Gb/s Operation 3 AIS Alarm Indication Signal BER Bit Error Rate)DWDM Dense Wavelength Division Multiplexing FEC Forward Error
6、 Correction LOF Loss of Frame)GD/J 1162020 2 LOS Loss of Signal MSTP Multi-Service Transport Platform MPI Main Path Interface MPI-S Source Main Path Interface Reference Point MPI-R Receive Main Path Interface Reference Point OA Optical Amplifier ODU Optical Demultiplexing Unit OMU Optical Multiplexi
7、ng Unit OSNR Optical Signal to Noise Ratio OTDR Optical Time Domain Reflectometer OTN Optical Transport Network OTU Optical Transponder Unit SDH Synchronous Digital Hierarchy)STM-N NSynchronous Transport Module Level N)WDM Wavelength Division Multiplexing 3R (Re-timingRe-shapingRe-amplification)4 4.
8、1 N10Gbit/s DWDM N10Gbit/sDWDM Mn.Bc-xWzs(E)MMS-ULH WDM nWDM BWDM10GWDM9.953Gbit/s12.5Gbit/s cWDMGHz xWDM WWDMdB A22dB B27dB zWDM 652G.652 655G.655 sWDM CC LL EWDMFECFEC N10Gbit/sDWDM1 GD/J 1162020 3 1 N10Gbit/sDWDM GHz MNdB M40.10G100-25A652(C)(E)100 2522dB G.652 4010Gbit/s M80.10G50-38A652(C)(E)50
9、 3822dB G.652 8010Gbit/s M80.10G50-15B652(C)(E)50 1527dB G.652 8010Gbit/s 4.2 N100Gbit/s DWDM N100Gbit/sDWDM Mn.Bc-xW-D-z(S)M100Gbit/s WDM nWDM BWDM100GWDM100Gbit/s130Gbit/sFEC cWDMGHz xWDM WWDMdB A22dB B25dB DWDM 1 0 zWDM 652G.652 655G.655 SWDM CC LL N100Gbit/sDWDM2 2 N100Gbit/sDWDM GHz MNdB M80.10
10、0G50-26A-0-652(C)50 2622dB G.652 80100Gbit/s M80.100G50-20A-0-652(C)50 2022dB G.652 M80.100G50-12B-0-652(C)50 1227dB G.652 GD/J 1162020 4 4.3 N100Gbit/s WDMC-band 1550nm193.1THz100GHz50GHz50GHz100GHz8040C40100GHz100G3C8050GHz100G4 3 C40100GHz100G C 100GHzTHz nm C 100GHzTHz nm 1a 196.20 1527.99 27 19
11、3.60 1548.51 2a 196.10 1528.77 28 193.50 1549.32 3 196.00 1529.55 29 193.40 1550.12 4 195.90 1530.33 30 193.30 1550.92 5 195.80 1531.12 31 193.20 1551.72 6 195.70 1531.90 32 193.10 1552.52 7 195.60 1532.68 33 193.00 1553.33 8 195.50 1533.47 34 192.90 1554.13 9 195.40 1534.25 35 192.80 1554.94 10 195
12、.30 1535.04 36 192.70 1555.75 11 195.20 1535.82 37 192.60 1556.55 12 195.10 1536.61 38 192.50 1557.36 13 195.00 1537.40 39 192.40 1558.17 14 194.90 1538.19 40 192.30 1558.98 15 194.80 1538.98 41 192.20 1559.79 16 194.70 1539.77 42 192.10 1560.61 17 194.60 1540.56 43 a 192.00 1561.42 18 194.50 1541.3
13、5 44 a 191.90 1562.23 19 194.40 1542.14 45 a 191.80 1563.05 20 194.30 1542.94 46 a 191.70 1563.87 21 194.20 1543.73 47 a 191.60 1564.68 22 194.10 1544.53 48 a 191.50 1565.50 23 194.00 1545.32 49 a 191.40 1566.32 24 193.90 1546.12 50 a 191.30 1567.14 25 193.80 1546.92 51 a 191.20 1567.95 26 193.70 15
14、47.72 52 a 191.10 1568.77 a 4152DWDM GD/J 1162020 5 4 C8050GHz100G C 50GHzTHz nm C 50GHzTHz nm 1a 196.25 1527.61 53 193.65 1548.11 2a 196.20 1527.99 54 193.60 1548.51 3a 196.15 1528.38 55 193.55 1548.91 4a 196.10 1528.77 56 193.50 1549.32 5 196.05 1529.16 57 193.45 1549.72 6 196.00 1529.55 58 193.40
15、 1550.12 7 195.95 1529.94 59 193.35 1550.52 8 195.90 1530.33 60 193.30 1550.92 9 195.85 1530.72 61 193.25 1551.32 10 195.80 1531.12 62 193.20 1551.72 11 195.75 1531.51 63 193.15 1552.12 12 195.70 1531.90 64 193.10 1552.52 13 195.65 1532.29 65 193.05 1552.93 14 195.60 1532.68 66 193.00 1553.33 15 195
16、.55 1533.07 67 192.95 1553.73 16 195.50 1533.47 68 192.90 1554.13 17 195.45 1533.86 69 192.85 1554.54 18 195.40 1534.25 70 192.80 1554.94 19 195.35 1534.64 71 192.75 1555.34 20 195.30 1535.04 72 192.70 1555.75 21 195.25 1535.43 73 192.65 1556.15 22 195.20 1535.82 74 192.60 1556.55 23 195.15 1536.22
17、75 192.55 1556.96 24 195.10 1536.61 76 192.50 1557.36 25 195.05 1537.00 77 192.45 1557.77 26 195.00 1537.40 78 192.40 1558.17 27 194.95 1537.79 79 192.35 1558.58 28 194.90 1538.19 80 192.30 1558.98 29 194.85 1538.58 81 192.25 1559.39 30 194.80 1538.98 82 192.20 1559.79 31 194.75 1539.37 83 192.15 15
18、60.20 32 194.70 1539.77 84 192.10 1560.61 33 194.65 1540.16 85 a 192.05 1561.01 34 194.60 1540.56 86 a 192.00 1561.42 35 194.55 1540.95 87 a 191.95 1561.83 36 194.50 1541.35 88 a 191.90 1562.23 37 194.45 1541.75 89 a 191.85 1562.64 38 194.40 1542.14 90 a 191.80 1563.05 GD/J 1162020 6 4 C 50GHzTHz nm
19、 C 50GHzTHz nm 39 194.35 1542.54 91 a 191.75 1563.46 40 194.30 1542.94 92 a 191.70 1563.87 41 194.25 1543.33 93 a 191.65 1564.27 42 194.20 1543.73 94 a 191.60 1564.68 43 194.15 1544.13 95 a 191.55 1565.09 44 194.10 1544.53 96 a 191.50 1565.50 45 194.05 1544.92 97 a 191.45 1565.91 46 194.00 1545.32 9
20、8 a 191.40 1566.32 47 193.95 1545.72 99 a 191.35 1566.73 48 193.90 1546.12 100 a 191.30 1567.14 49 193.85 1546.52 101 a 191.25 1567.54 50 193.80 1546.92 102 a 191.20 1567.95 51 193.75 1547.32 103a 191.15 1568.36 52 193.70 1547.72 104 a 191.10 1568.77 a 81104DWDM 5 WDM1OTN,1OTU3RITU-T G.692OMUOAODUTx
21、/Rx O M U O D U OA MPI-SM RM OA SM RM OA SM MPI-RM OA O D U O M U MPI-RM SM OA RM SM OA RM MPI-SM OA OA Tx1TxRxRxRxRxTxTx1nnnn111SnS1RnR1SnS1RnROTUOTUOTUOTUOTUOTUOTUOTU 1 WDM 16SMPI-SMRMSMMPI-RMR,2SnRnS RWDMMPI-SMRMSMMPI-RMWDMSnRnWDMOTUOMUODU GD/J 1162020 7 a)S b)SnOTUOMU c)MPI-SMOMUOA d)RMOA e)SMOA
22、 f)MPI-RMODUOA g)RnODUOTU h)R 6 6.1 10Gbit/s 10Gbit/s56 5 G.65210Gbit/s Na22dB N22dB N30dB N30dB G.652 80 160 80 160/STM-64 STM-64 STM-64 STM-64 MPI-S 1 2dBm6dBm 0dBm4dBm 3dBm6dBm 0dBm3dBm 2 23dBm 23dBm 23dBm 23dBm 3 35dB 35dB 35dB 35dB 4 4dB 4dB 3dB 3dB MPI-R 5 -22dBm-16dBm-24dBm-18dBm-27dBm-22dBm-
23、30dBm-25dBm 6 1dBm 1dBm-5dBm-5dBm 7 b 2018dB 2018dB 2018dB 2018dB 8 6dB 6dB 5dB 5dB a b FECWDM20dBFECWDMOSNR18dB GD/J 1162020 8 6 G.65510Gbit/s N22dB N22dB N30dB N30dB G.655 80 160 80 160/STM-64 STM-64 STM-64 STM-64 MPI-S 1 2dBm6dBm 0dBm4dBm 3dBm6dBm 0dBm3dBm 2 23dBm 23dBm 20dBm 23dBm 3 35dB 35dB 35
24、dB 35dB 4 4dB 4dB 3dB 3dB MPI-R 5 -22dBm-16dBm-24dBm-18dBm-27dBm-22dBm-30dBm-25dBm 6 1dBm 1dBm-5dBm-5dBm 7 2018dB 2018dB 2018dB 2018dB 8 6dB 6dB 5dB 5dB 6.2 100Gbit/s 100Gbit/s7 7 100Gbit/s 1822dB 1422dB 1622dB 1022dB 80 80 80 80 100Gbit/s130Gbit/s MPI-S 1 -2dBm4dBm-2dBm4dBm-3dBm3dBm-3dBm3dBm 2 20dB
25、m 20dBm 19dBm 19dBm 3 6dB 6dB 6dB 6dB MPI-R 4 -24dBm-18dBm-24dBm-18dBm-25dBm-19dBm-25dBm-19dBm 5 -2dBm-2dBm-3dBm-3dBm 6 18.5dB 20dB 18.5dB 19.5dB 7 6dB 6dB 6dB 6dB 7 OTU 7.1 OTU OTUOTUOTUOTUOTU GD/J 1162020 9 7.2 OTU OTU S/RITU-T G.691ITU-T G.693ITU-T G.959.1IEEE 802.3baGE10GE100GEIEEE 802.3ba OTUSn
26、/Rn8 8 OTUSn/Rn N100Gbit/s WDM N10Gbit/s WDM -20dB 1nm 0.3nm 35dB 35dB 5dBm-1dBm -5dBm-10dBm ITU-T G.957 ITU-T G.691 NA 8.2dB 2 2 2.5GHz 5GHz -14dBm-21dBm 0dBm-9dBm 7.3 9 9 (-3dB)-1 STM-1 500Hz1.3MHz 0.3UIpp 2 65kHz1.3MHz 0.1UIpp 3 STM-4 1kHz5MHz 0.3UIpp 4 250kHz5MHz 0.1UIpp 5 STM-16 5kHz20MHz 0.3UI
27、pp 6 1MHz20MHz 0.1UIpp 7 STM-64 20kHz80MHz 0.3UIpp 8 4MHz80MHz 0.1UIpp 9 STM-256 80kHz320MHz 0.3UIpp 10 16M320M 0.14UIpp 8 8.1 10 GD/J 1162020 10 10 40 80 1 100GHz 50GHz 2 3dB 3dB 3 10dB 10dB 4 40dB 40dB 5 22dB 22dB 6 25dB 25dB 8.2 11 11 40 80 1 100GHz 50GHz 2 8dB 8dB 3 40dB 40dB 4-20dB 1.2nm 0.6nm
28、5 22dB 25dB 6 25dB 25dB 9 12 12 N10Gbit/s N100Gbit/s 1 YD/T 196020098 YD/T 3070201610 2 2dB 2dB 10 13 GD/J 1162020 11 13 1 1510nm 2 10nm 3 -70dBm 4 -48dBm 11/SDHOTN24hBER0 24h 12 YD/T 33912018 50ms1200km a)LOS b)LOF c)AIS d)13 13.1 13.1.1 MPI-S 13.1.1.1 2 2 TX1TX2TXnMPI-SGD/J 1162020 12 a)2 b)MPI-S
29、c)13.1.1.2 3 3 a)3 b)MPI-SM c)13.1.1.3 3 a)3 b)c)13.1.1.4 3 a)3 b)c)d)AB e)P=A-B 13.1.2 MPI-R 13.1.2.1 4 TX1TX2TXnMPI-SGD/J 1162020 13 4 a)4 b)MPI-R c)13.1.2.2 4 5 a)5 b)MPI-RM c)13.1.2.3 5 a)5 b)c)13.1.2.4 5 TX1TX2TXnMPI-SMPI-RTX1TX2TXnMPI-SMPI-RGD/J 1162020 14 a)5 b)c)d)AB e)P=A-B 13.2 OTU 13.2.1-
30、20dB 6 6-20dB a)6 b)SDHSTM-N c)-20dB d)-20dB 13.2.2 6 a)6 b)SDHSTM-N c)d)13.2.3 7 SDHTXRXRXTXGD/J 1162020 15 7 a)7 b)SDHSTM-N c)d)13.2.4 8 8 a)8 b)SDHSTM-N c)d)13.2.5 8 a)8 b)SDHSTM-N c)d)SDHTXRXRXTXSDHTXRXRXTXGD/J 1162020 16 13.2.6 6 a)6 b)SDHSTM-N c)d)e)13.2.7 9 9 a)9 b)SDHSTM-NSDHSDH c)SDH d)13.2
31、.8 10 SDHTXRXTXRX 10 a)10 SDHTXRXRXTXGD/J 1162020 17 b)SDH c)SDH d)60s 13.2.9 9 a)9 b)SDHSTM-NSDHSDH c)SDH d)13.3 13.3.1 13.3.1.1 11 RX1RX2RXnTX 11 a)11 b)c)d)e)13.3.1.2 12 GD/J 1162020 18 12 a)12 b)A c)BC=A-B d)13.3.1.3 13 13 a)13 b)OTDR c)13.3.1.4 12 a)12 b)MA c)BC=A-B d)M1D e)EF=D-E f)M1MG=F-C g)
32、OTDRRX1RX2RXnTX10kmGD/J 1162020 19 13.3.1.5 12 a)12 b)MA c)BC=A-B d)MN(N2)D e)EF=D-E f)MN(N2)MG=F-C g)13.3.2 13.3.2.1 14 RX1TXnTX1TX2 14-20dB a)14 b)c)d)e)f)13.3.2.2 15 15 GD/J 1162020 20 a)15 b)A c)BC=A-B d)13.3.2.3 16 16 a)16 b)OTDR c)13.3.2.4-20dB 14 a)14 b)c)-20dB d)13.3.2.5 15 a)15 b)MA c)BC=A-
33、B d)M1D e)EF=D-E f)M1MG=F-C g)13.3.2.6 OTDRRX1TX2TXnTX110kmGD/J 1162020 21 15 a)15 b)MA c)BC=A-B d)MN(N2)D e)EF=D-E f)MN(N2)MG=F-C g)13.4 13.4.1 17 17 a)17 b)1PIN-i c)POUT-i d)13.4.2 17 a)17 b)13.4.1b)d)1n c)13.5 13.5.1 18 12GD/J 1162020 22 18 a)18 b)c)d)13.5.2 18 a)18 b)c)d)13.5.3 19 19 TXRXRXTXTXR
34、XRXTXGD/J 1162020 23 a)19 b)c)d)13.5.4 20 20 a)20 b)c)d)13.6/21 21/a)21 b)SDH/OTN c)SDH/OTN d)15minTXRXRXTXSDH/OTNTXRXTXRXGD/J 1162020 24 15min e)24hSDH/OTN f)/13.7 22 22 a)22 b),SDH/OTN,SDH/OTN c)SDH/OTN d)e)W f)SDH g)ef5 SDH/OTNSDH/OTNWPWPGD/J 1162020 25 1 GB/T 168142008 SDH 2 YD/T 10602000 WDM322.5Gb/s 3 YD/T 11432001 WDM1610Gb/s3210Gb/s 4 YD/T 11592016 WDM 5 YD/T 12052010 WDM 6 YD/T 12742003 WDM16010Gb/s8010Gb/s 7 YD/T 24852013 N100Gbit/s(WDM)8 YD/T 26492013 N100Gbit/sWDM 9 YD/T 34022018 N100Gbit/sWDM _