资源描述
Thank you for your using air source water heater series products. Please read instruction book before use and keep it for future reference. Please record the machine model and serial number on the warranty card.
Adaptive Model Number: JN-100L、150L、200L、300L.
Catalog
1. Cautions-----------------------------------------------------
2. Performance and Features---------------------------------
3. Performance Parameter------------------------------------
4. Operation Instructions-------------------------------------
5. Product Structure-------------------------------------------
6. Outdoor Circuit Diagram----------------------------------
7. Care and Maintenance-------------------------------------
8. Simple Trouble Self-examination------------------------
9. Warranty card------------------------------------------------
1. Cautions
Thanks for your purchasing our products, please note the following points:
a. Read this instruction book carefully before installation!
b. It shall be installed follow the rule of National TWiring Rule;T
c. Power socket shall be triplex receptacle with safe ground wire and match with the machine plug. The content shall no less than 2 times of machine rated current. The socket shall be near the machine and in the place of plug reached.
d. It shall use special branch circuit that 2 times more than maximum rated current. The wire shall match to the maximum value of customer use. The circuit shall hold suitable all-pole disconnection protector (1.5-2 times more than rated current.
e. The display board shall be installed in the shade dry place.
f. Keep the water tank full before the power socket is connected at the first time. Please do not close the water valve at the time of normal use or it will not make the water outlet.
g. Do not set over heated water as you would like to. As the water temperature reach to the 55℃. You should mix the cool water with hot water for being scalded (especially old man and children);
h. Do not install and move the machine by yourself. All works shall be done by professional install workers.
i. As the trouble made by customers, the company will not be responsible for it.
2. Performance and Features
Air source water heater is usually used in the places of family house, bathing spot and hotel. The main advantages as follows:
Energy Conservation Compare with general water heater, it holds lowest operation costs. It is lower than electrical solar water heater in the whole year.
Ø Environment Protection Free from contamination. It use new type refrigerant that zero emission onto ozonosphere. Besides that, it does not make any excreta.
Ø All-weather Does not be influenced by bad weather such as overcast and rainy and snow. It could normal be used among -10℃~43℃. It works effectively in dry and wet places with Intelligent defrost system.
Ø Reliable Quality Use well known best quality special compressor, food grade stainless steel tank. It could be used for more than 15 years under normal use.
Ø Safety Real completely separated water from electricity;
Ø Convenient Easy installation and smaller floor space. It could be installed in a suitable places and content the requirement of customers.
3. Performance Parameter
Model No.
JN-100L-30W
JN-150L-30W
JN-200L-40W
JN-300L-40W
Tank Volume(L)
100
150
200
300
Heat Speed(L/h)
75
75
95
95
Max Leaving Water Temp (℃)
60℃
Power
220V/50Hz
Rated Input Power (W)
940
1280
1280
2000
Tank Bearing Pressure
0.6Mpa
Temp Range(℃)
-10 ℃~ 43 ℃
Tank Weight (kg)
26
36
46
65
Tank Out Size
¢480×1074
¢480×1514
¢570×1300
¢570×1835
Machine Weight (kg)
27
36
36
45
Machine Out Size
790*255*540
790*255*540
790*255*540
790*255*540
Suited People
1~3
2~4
2~4
Above 4
Note: Heat water compensation speed is tested in the condition of 20℃ Wet-bulb temperature, 20℃inlet water temperature, 55℃leaving water temperature. This list parameter is for reference only. Detail parameter is subject to the machine brand.
4. Operation Instructions
a. Temperature Display: the controller shows the water temperature in the tank. Press “▼”, it will show the outside temperature.
b. ON/OFF: Press “⊙” to ON/OFF machine. As in the conditions of ON, it shows “heat”, “heat insulation”, “defrosting”. It shows “OFF” while the machine is power off. Whenever the condition is, it always shows the present time and present temperature.
c. Temperature Setting: Press “S” and get into the temperature setting condition. As it shows the “ceiling temperature”, press “▲” or “▼” to change the value (press “▲” to raise 1℃, press “▼” to fall down 1℃; hold “▲” or “▼” for more than 0.5 second, it will raise and fall down quickly). Press “S” again and the floor temperature setting method follows ceiling temperature. As setting finished, press “▲” once again to go back from setting condition. It will begin to work as the temperature lower than the floor temperature or higher than ceiling temperature and make the water temperature between “floor temperature” and “ceiling temperature”
d. Time setting: press “¹”, the hour part will be shining, press “▲” or “▼” to adjust the hour part; press “¹” again to adjust the minutes part, press “▲” once again to finish.
e. Operating Mode Setting: Press “M” and shift “Automatic” to “Economic”. Under the “Automatic” model, it will control the water temperature according to the pre-setting. Under the “Economic” model, only make the water hot in the pre set time.
f. Work Period under Economic Model Setting: hold the “¹” for 2 seconds and set three heat period as screen shows. (“¹” is used for switch the project, “▲” or “▼” is used for value change). If you do not need so many setting period, you could make the start time and finish time on “00:00”. If the start time is later than finish time, it will consider that the finished time is on the next day. For example: if you set the one of the period on “22:00” to “03:30”, the machine will consider the period is start from 22:00 and finish in 3:30 next day.
5. Product Structure
(Fig 1)
6. Outdoor Circuit Diagram
*Note: Non-professionals are not allowed to change! *
7. Care and Maintenance
Fault Display
Fault Cause
Show “OPE”
Open circuit on water tank test line or outside machine test line
Show “ SHR”
Short circuit on water tank test line or outside machine test line
Show “Drop”
Communication failures between display panel and outside control board
Show “leakage”
Machine electric leakage
Alarm on failures defrosting
During the settled time, machine temperature could not reach to the settled defrosting temperature.
Alarm on high temperature
The temperature is 10℃ higher than ceiling.
Ø For long time work, there is some dust on heat interchanger aluminum foil. It shall be brushed with water regularly or it would have effect on heat absorption. As there are great amount of dust, please let professionals clean.
Ø Check the connect end is leak or not regularly. Please contact the professionals to repair it if it is leak.
Ø Check the wire is plug, socket and wire is well connected or not regularly.
Ø As the machine has some informal noise, you should power off it and contact the professionals.
Healthy Symptom
The symptom as follows does not mean something had happened to the machine:
a. For the compressor’s defective function, the machine does not start for 3 minutes.
b. There is some condensed water discharged from the outdoor machine.
c. Some noise in the machine. As the machine worked, there is some bicker or sizzle noise. It is a normal noise from refrigerant.
d. For safety valves’ pressure relieve function, the valve will discharge some water to relieve as the water tank get overpressure.
8. Simple Trouble Self-examination
Symptom
Fault Cause
Solution
Compressor does not work
Main power does not be connected
Check up on both incoming line and air switch
The control panel does not open
Press the “ON” key
Fault code on drive-by-wire controller
Check follows the code table
Can not reach to the setting temperature for long time heating.
Dust on heat interchanger, the ambient temperature is too cold, refrigerant is discharged
Clean the heat interchanger; improve the environment; check on leakage point, supplement some refrigerant
No words on the display panel
Main power does not be connected
Check on incoming line and air switch
Poor contact on signal wire
Check on signal wire and fittings
Can not make hot water and the main machine blows hot wind
Four-way valve or four-way valve loop is broken
Replace four-way valve or four-way valve loop
Wiring harness is loose
Keep the line be connected
Fan can not work
Either fan or capacitance is broken
Replace fan or capacitance
Wiring harness is loose
Keep the line be connected
Big noise as the machine work
Frame screw loose
screw down screw
Some copper pipes touched each other in the machine
Check on the copper pipes
Note: 1. The test or disconnect failure will be solved as both test and communication are recovered.
2. The high temperature alarm will be discharged as the water temperature drop to the normal.
3. There are some ways to solve the problem of defrosting failure as followed
a) The outdoor machine temperature is higher than defrosting start temperature.
b) Press “⊙” key to close the machine.
9. Warranty card
Warranty card (Please send affiliated card to us and reserve the original card)
In order to keep our service promise and release customers from worries, we will establish customer info file in our company computer system.
Ø Please complete the warranty card and send our the affiliated card in one month
Ø If the original card or purchasing proof is missing, you could look up your customer info file and get some related service.
a. Products Info
Purchase date
Purchase Place
Model. No.
Factory Number
Purchase price
b. Customer Info
Name
Job
Zip Code
Phone Number
Address
Note: please tear out this part and send it to us as follow requirement (copy here of is invalid)
Please fill this warranty card and send us the affiliated card as soon as possible.
Please fill this warranty card and send us the affiliated card as soon as possible.
Zip Code:
Address
After service Department
Warranty card (Reserve the original card)
Ø To shops: this warranty card is a clear proof for customers. The sales should write down the warranty card for customers and give it to customers.
Ø To customers: free repair during warranty period. Customers should keep the card. Please note that maybe there are some conditions about exchange parts or goods.
Products Name
Factory Number
NO:
Type No.
Guarantee time
From Month Year in one year is valid
Purchasing date
Date Month Year
Store name
Tel
Address
Zip.
Customer Name
Tel
Address
Zip.
Guarantee Card
Problem & Date
Repair fees
Part you exchanged:
Charging Method
free/not free
Repair Method:
Repair People
Products Name
Factory Number
NO:
Type No.
Guarantee time
From Month Year in one year is valid
Purchasing date
Date Month Year
Store name
Tel
Address
Zip.
Customer Name
Tel
Address
Zip.
Guarantee Card
Problem & Date
Repair fees
Part you exchanged:
Charging Method
free/not free
Repair Method:
Repair People
Thank you for your using air source water heater series products. Please read instruction book before use and keep it for future reference.
Adaptive Model Number: JN-100L、150L、200L、300L.
Catalog
1. Installation Instructions …………………………………
a. Main Machine Installation Site
b. Main Machine Installation Steps
c. Temperature Hold Box Site
d. Temperature Hold Box Installation Steps
e. Heat Connecting Hose Installation
f. Leakage Checking on Connecting Host
g. Connections of Circuits
h. Test Running
g. Remove air source
1. Installation Instructions
a. Main Machine Installation Site
(1) As the main machine was installed on the wall or roof, the place they installed shall be made of solid brick, concrete or other strength place. The main install place shall load more than 300kg/m2. Keep it upright and level.
(2) The install face shall made of wood or metal that has enough firm.
(3) The space between main machine and obstacles shall not smaller than the space showed in (Figure 1)
(4)If you install the canopy, please note that it shall not block heat absorption and dissipation of the main machine
(5) The space between main machine and water tank will not longer than 2.5m (there are some length limitation on main connection host).
b. Main Machine Installation Steps
(1) Direct installation (With customer permission, ensure that there is no leak in expanded hole)
(a) Mapping the space between the outside installation holes. Mark the pre-installed place.
(b) Dig 4 M12.5 holes by impact drivers
(c) Fix the outside machine by M8 steel setscrew.
Thank you for your using air source water heater series products. Please read instruction book before use and keep it for future reference.
Adaptive Model Number: JN-100L、150L、200L、300L.
Catalog
1. Installation Instructions …………………………………
a. Main Machine Installation Site
b. Main Machine Installation Steps
c. Temperature Hold Box Site
d. Temperature Hold Box Installation Steps
e. Heat Connecting Hose Installation
f. Leakage Checking on Connecting Host
g. Connections of Circuits
h. Test Running
g. Remove air source
1. Installation Instructions
a. Main Machine Installation Site
(1) As the main machine was installed on the wall or roof, the place they installed shall be made of solid brick, concrete or other strength place. The main install place shall load more than 300kg/m2. Keep it upright and level.
(2) The install face shall made of wood or metal that has enough firm.
(3) The space between main machine and obstacles shall not smaller than the space showed in (Figure 1)
(4)If you install the canopy, please note that it shall not block heat absorption and dissipation of the main machine
(5) The space between main machine and water tank will not longer than 2.5m (there are some length limitation on main connection host).
b. Main Machine Installation Steps
(1) Direct installation (With customer permission, ensure that there is no leak in expanded hole)
(a) Mapping the space between the outside installation holes. Mark the pre-installed place.
(b) Dig 4 M12.5 holes by impact drivers
(c) Fix the outside machine by M8 steel setscrew.
Note During Direct installation:
Ø It shall be permitted by customers
Ø It will not be leak from the expanded hole
Ø Note the discharge of condense water
(2) U