1、CSPC Nanhai Petrochemicals ProjectSEPCO Electric Power Construction Corp CSPC 南 海 石 化 项 目发电机电气试验作业指导书GENERATOR TEST工作程序: WI-8710-8100-0062山东电力基本建设总公司 版次日 期出版原因编写校核审查批准AJanuary 12, 2004Issue For Review And ApprovalZhang .FGLi .WQXiao .TPTian .GHBMar 4, 2004Issue For Review And ApprovalZeng .GYLi .WQX
2、iao .TPTian .GHCApr 24, 2004Issue For Review And ApprovalZeng .GYLi .WQXiao .TPTian .GH版次REV章节号Section No.修改内容Description of main changesAB工作步骤不够详细The work process is not detailed enough. 增加和完善了工作步骤Add and improve the work process.C工作步骤不够详细The work process is not detailed enough. 增加和完善了工作步骤Add and i
3、mprove the work process. 修改纪录The modification records目 录Contents1.0 工程概况 Gnereral introduction 2.0 编制依据 References 3.0 施工准备 Construction preparation 4.0 主要施工机械及工具 Main machinery and tools 5.0 试验项目 Test items 6.0 劳动力组织 Labor force 7.0 施工工序和施工方法 Construction procedure and plans 8.0 工作安全分析 JSA 1.0 工程概况
4、:General introduction 中国南海石化汽电联产项目共有五台发电机,其中:There are 5 generators in Steam & Power unit for CSPC Nanhai petrochemicalsproject, thereinto: 燃气机组(1台) 型号:TA30-46 有功功率:42.4MW 视在功率:53MVA 功率因数:0.8 电压:1110.0%kV 额定电流:2748A 频率:50HZ 转速:3000转秒 相数:3相 联结方式:星型 生产厂家:ALSTOMOne used for gas turbine unit: TYPE:TA30-
5、46, Active power:42.4MW, Apparent power: 53MVA,Power factor:0.8, Rated voltage: 1110.0%kV, Phase:3相,Rated current:2748A , Frenquency:50HZ, Rotation speed:3000转秒, Coupling of phase:star Manufacturer:ALSTOM汽轮发电机(4台)型号:TLRI 92/26 容量:75MVA 功率因数:0.8额定电流:3936A 电压范围:+10.0-10.0% 额定电压:11kV频率:50HZ 转速:3000转秒 相
6、数:3相 联结方式:YY 生产厂家:SIEMENS AGSteam Turbine Generators(14): TYPE:TLRI 92/26, Capacity:75MVA, Rated current: 3936A,Voltage range: 1110.0% kV,Power factor:0.8, Phase:3相Frenquency :50HZ, Rotation speed:3000转秒, Coupling of phase:YY Manufacturer:SIEMENS AG2.0 编制依据:References 2.1 DEP 63.10.08.11 Field Commi
7、ss & Main of Elec Installations Equip.2.2 电气装置安装工程电气设备交接试验标准(GB5015091) Standard for electric equipment test of electric equipment installation engineering(GB5015091)2.3 电力建设安全工作规程DL5009.1-92 Safety work regulations of electric power constructionDL5009.1-922.4 发电机出厂技术资料 Ex-factory technique informat
8、ion 2.5 发电机出厂试验报告 Ex-factory test report3.0 施工准备: Construction preparation 3.1 发电机已运至现场就位安装,外壳接地良好,绕组引出线与地安全距离充足。 The generator has been delivered and located and installed on the site, the casing earthed well, and enough distance is necessary between the lead-out wire of stator and earth. 3.2 现场已清理
9、干净、道路通畅。 The site has been cleaned up, and the road is unblocked. 3.3 本作业指导书及安全技术措施已编制审批完毕,对所有参加试验人员交底并签字,交底记录齐全。 The preparation of the work instruction and safety technique measures has been completed, and the examination and approval also has been done. All personnel attending the test have been
10、told the real intentions and sign it up. The record is all ready. 3.4 试验仪器准备齐全,工作正常,试验人员熟悉仪器的使用方法。 The test apparatus has been prepared, and they work in gear. The test personnel are familiar with the using way of apparatus. 3.5 施工图纸及有关技术资料齐全。 The construction drawing and relative technical information are all ready. 3.6 试验所需工具准备齐全。 Tools for test required are all ready. 3.7 试验区域拉好警戒绳,挂上明显的警示牌。 Set the warning rope in test area and hang the visible warning card. 3.8 试验用电源开关要悬挂“试验专用,严禁乱动”警示牌。 The warning card which is saying “ Special for use, dont fiddle with it” from