资源描述
(完整版)开关电源 测试报告
Item
Test
Specification
Result
Page #
Remarks
A. INPUT CHARACTERIZATION
1。1
Input Current/Power/Efficiency/Power Factor
Eff%〉84%;Iin<1.5A
PASS
3
1.2
No Load Input Power & Active Mode Efficiency
No load (Pin<0.5W);
0。5W load (Pin<1。0W);
1.0W load (Pin<1。7W); 1.5W load (Pin<2.4W);
11.6W load (Pin<14W)
18.7W load (Pin<22W)
Average efficiency〉87%
PASS
4
1.3
Acoustic Noise
<25dB(A)
PASS
6
1.4
Inrush Current
No damaged(Cold Start)
PASS
7
1.5
Line Cycle Dropout
No latch off
PASS
9
1.6
Brownout & BO Recovery
No damaged
PASS
11
1。7
Total Harmonic Distortion
To start up and no damage
PASS
12
1.8
Line Voltage Surge
No damaged
PASS
13
1.9
Line Voltage Sag
No damaged
PASS
14
1。10
AC Voltage Dip Immunity
No latch off
PASS
15
1.11
Harmonic Current
EN61000—3-2 class D
PASS
16
B。 OUTPUT CHARACTERIZATION
2.1
Load, Line Cross Regulation
18。55Vdc ~ 19。95Vdc
PASS
18
2.2
Peak Load
6。16Asurge load for2mSec;
Vo>17Vdc
PASS
19
2.3
Ripple and Noise
〈380mVp—p
PASS
20
2。4
Dynamic Loading Response
18。55Vdc ~ 19。95Vdc
PASS
22
2.5
Output Over / Under Shoot
〈10%
PASS
24
2。6
Turn On Delay/ Hold up / DC Rise/Fall Time
Power—on time<2Sec;
Hold up time >5mS;
Rise time 〈100mS
PASS
26
2.7
Loop Gain
> 45 deg.
PASS
30
C. PROTECTION
3.1
Short circuit Protection
No damage
PASS
31
3.2
Over Current Protection
>5。7A
PASS
33
3.3
Over Voltage Protection
Vmax:27V
PASS
34
D. EMC/SAFETY/ENVIRONMENTAL
4.1
Electric Strength (Hi-Pot)
<10mA
PASS
36
4.2
Leakage Current
〈50uA@100Vac; 〈100uA@240Vac.
PASS
37
4。3
Insulation Resistance (IR)
>20MΩ
PASS
38
4。4
Electromagnetic Discharge (ESD)
IEC61000—4—2
PASS
39
4。5
Electromagnetic Fast Transient And Burst (EFT)
IEC61000-4—4
PASS
41
4。6
AC Surge Immunity (PLD_BI Wave)
EN61000—4—5
PASS
43
4.7
Electromagnetic Compatibility
Under -6dB
PASS
45
Pass / Fail: According to specification 4 hours storage at 0℃, and operating at 40℃
N。S。 : Not Specified Test Equipment: TOPNOTCH OTC—2B-N Open Chamber
N。T。 : Not Tested CHROMA Series AC Source / DC Load
Prepared
Checked (TE)
Checked (EE)
Approved
Page 67 of 67
A. INPUT CHARACTERIZATION
1。1 INPUT CURRENT/POWER/EFFICIENCY/POWER FACTOR
Test conditions:
The unit is set at maximum load and the input voltage is varied from the minimum to the maximum value. Efficiency is computed and Power Factor is either computed or measured after 10 minutes warm up at least。
Test equipment:
Chroma Model 8000 Power Supply Auto Test System
Chroma Model # 6590 9KVA Low Impedance AC Source
Chroma Model # 630X0 DC Load
Chroma Model # 6630 Power Analyzer
Pass/Fail criteria:
The unit test shall meet the specification requirements.
Test result: PASS
@25°C
Vin(Vac)
Freq(Hz)
Iin(A)
Pin(W)
Vout(V)
Pout(W)
Pd(W)
PF
Eff(%)
90.000
47.000
1.283
103。900
18.790
88.853
15。047
0。899
85.518
100。000
50.000
1.128
102。700
18。788
88.877
13。823
0。908
86.540
115.000
50。000
0。965
101。600
18。802
88.948
12。652
0。913
87。547
120。000
50。000
0.924
101。500
18。780
88。806
12。694
0。913
87.494
130.000
50。000
0.851
101。200
18。780
88。841
12.359
0。912
87.788
140。000
50。000
0。790
100.900
18.788
88.877
12.023
0.910
88.084
150。000
50.000
0.738
100.800
18。790
88.888
11.912
0。907
88。183
160.000
60.000
0。695
100。700
18.802
88.948
11。752
0.903
88.329
170.000
60。000
0。655
100.400
18。798
88。924
11。476
0.899
88.570
180。000
60.000
0.620
100.500
18.792
88.900
11.600
0。897
88。458
190。000
60.000
0.589
100。300
18.785
88.865
11。435
0。893
88。599
200。000
60.000
0。563
100.400
18.788
88.841
11.559
0。888
88。487
210.000
60.000
0.539
100.500
18。785
88。830
11。670
0.884
88。388
220。000
60。000
0.517
100。500
18.788
88。877
11。623
0。879
88.434
230。000
60。000
0.498
100.700
18.792
88.900
11.800
0。875
88。282
240.000
60.000
0.481
100.800
18。795
88.877
11。923
0.870
88。171
250。000
60。000
0。465
100.800
18.805
88。924
11。876
0。865
88.218
264。000
63.000
0.447
101。000
18。790
88.853
12.147
0。853
87。973
@0°C
Vin(Vac)
Freq(Hz)
Iin(A)
Pin(W)
Vout(V)
Pout(W)
Pd(W)
PF
Eff(%)
90.000
47。000
1.279
103。600
18。870
89。232
14.368
0。899
86。131
100。000
50。000
1.127
102.300
18。868
89.255
13。045
0。907
87.248
115.000
50。000
0。967
101。500
18。875
89。255
12.245
0.911
87。936
120.000
50.000
0.926
101。300
18。868
89.220
12.080
0.909
88。075
130.000
50.000
0.852
101。200
18.880
89.279
11。921
0.909
88。220
140.000
50。000
0。789
100。700
18。862
89.196
11。504
0.909
88.576
150。000
50.000
0。739
100。500
18。882
89。291
11.209
0。905
88。846
160。000
60。000
0.693
100。400
18.870
89。232
11.168
0.902
88.876
170.000
60。000
0.654
100.200
18。868
89.255
10。945
0。899
89。077
180。000
60。000
0。619
100.100
18.868
89.220
10。880
0.896
89。131
190.000
60.000
0。588
100。100
18。868
89.220
10。880
0.893
89.131
200。000
60.000
0。561
100.200
18。872
89.243
10。957
0。889
89。065
210.000
60。000
0。537
100.200
18.880
89.279
10。921
0.885
89.101
220。000
60.000
0。516
100。300
18.882
89.291
11。009
0.880
89。024
230。000
60.000
0。496
100.200
18.885
89.302
10。898
0。875
89。124
240。000
60。000
0。479
100.300
18.885
89。302
10.998
0.870
89。035
250.000
60.000
0。463
100。400
18。878
89。267
11.133
0.864
88.911
264.000
63.000
0。444
100.400
18.875
89.255
11.145
0.853
88。900
@40°C
Vin(Vac)
Freq(Hz)
Iin(A)
Pin(W)
Vout(V)
Pout(W)
Pd(W)
PF
Eff(%)
90.000
47。000
1.276
103。600
18.865
89.172
14.428
0。901
86。074
100.000
50。000
1。125
102。300
18。860
89。149
13。151
0.907
87.145
115。000
50.000
0.963
101。200
18。868
89。184
12。016
0.911
88.127
120。000
50。000
0.922
101。100
18。872
89.208
11.892
0.912
88。237
130.000
50.000
0。849
100.800
18。880
89.243
11.557
0。910
88.535
140.000
50.000
0.787
100.500
18.882
89。255
11。245
0。909
88。811
150.000
50.000
0。735
100.400
18.870
89。196
11.204
0。907
88.841
160。000
60。000
0。692
100.200
18.862
89。161
11。039
0.903
88.983
170。000
60。000
0。652
100.000
18。862
89.161
10。839
0.899
89.161
180.000
60。000
0.618
100.100
18。868
89.184
10。916
0。896
89.095
190。000
60.000
0。587
99.800
18。875
89。220
10.580
0.893
89.399
200。000
60.000
0.560
99。900
18.885
89。267
10.633
0。889
89。356
210。000
60.000
0.536
100。100
18。885
89。267
10.833
0。885
89.178
220.000
60.000
0。515
99。900
18.882
89。255
10。645
0。880
89.345
230.000
60。000
0.495
100.100
18.878
89。232
10。868
0.875
89。142
240.000
60。000
0.477
100.100
18。870
89。196
10.904
0.870
89.107
250.000
60。000
0。462
100。200
18.865
89.172
11.028
0.864
88。995
264。000
63.000
0.444
100。400
18。872
89。208
11.192
0.854
88.853
1。2 ACTIVE MODE EFFICIENCY & NO LOAD INPUT POWER
Test conditions:
The unit is set at no load and the rated input voltage for at least 15 minutes.
The ambient temperature is set between 15 Deg C to 35 Deg C
Test equipment:
Chroma Model 8000 Power Supply Auto Test System
Chroma Model # 65909KVA Low Impedance AC Source
Chroma Model # 630X0 DC Load
Chroma Model # 6630 Power Analyzer
Pass/Fail criteria:
The unit test shall meet the specification requirements.
Test result: PASS
No Load Power Consumption: (Pin〈0。5W)
Input Voltage(Vac)
Load(W)
Iin rms(A)
Power Factor
Pin(W)
Vo (Vdc)
115
0.00
0.050
0.010
0。281
19。347
230
0。00
0。084
0。016
0。310
19。347
0.5W Load Power Consumption: (Pin〈1。0W)
Input Voltage(Vac)
Load(W)
Iin rms(A)
Power Factor
Pin(W)
Vo (Vdc)
115
0。5
0.051
0.073
0。432
19.345
230
0。5
0。084
0.029
0。590
19.345
1。0W Load Power Consumption: (Pin〈1.7W)
Input Voltage(Vac)
Load(W)
Iin rms(A)
Power Factor
Pin(W)
Vo (Vdc)
115
1。0
0.053
0。177
1.074
19.343
230
1.0
0.085
0.063
1。240
19.343
1。5W Load Power Consumption: (Pin<2。4W)
Input Voltage(Vac)
Load(W)
Iin rms(A)
Power Factor
Pin(W)
Vo (Vdc)
115
1。50
0。055
0。273
1。723
19。337
230
1。50
0。086
0。096
1.900
19。337
11。6W Load Power Consumption: (Pin〈14W)
Input Voltage(Vac)
Load(W)
Iin rms(A)
Power Factor
Pin(W)
Vo (Vdc)
115
11.6
0。141
0.806
13。130
19.285
230
11.6
0.109
0。526
13.170
19.270
18.7W Load Power Consumption: (Pin<22W)
Input Voltage(Vac)
Load(W)
Iin rms(A)
Power Factor
Pin(W)
Vo (Vdc)
115
18。7
0.210
0.863
20。960
19。237
230
18。7
0.136
0.682
21.420
19.237
Active Mode Efficiency:
Vin (Vac)
Fin (Hz)
Iin (A)
Pin (W)
Iout (A)
Vout (V)
Pout (W)
Pd(W)
P。F
Eff(%)
THD(%)
Average EFF(%)
Result
115。0
60。0
0.963
101。40
4.731
18.78
88.86
12。54
0。91
87。638
0。10
88。820
PASS
115.0
60.0
0.724
75.90
3。547
18。93
67.15
8.75
0。91
88。465
0。10
115.0
60.0
0。484
50.30
2.364
19.07
45。09
5。21
0。90
89.651
0.11
115。0
60。0
0。251
25。35
1.181
19.21
22.69
2.66
0.88
89.526
0。12
115.0
60.0
0.050
0.17
0.002
19。34
0。04
0。13
0。03
21.714
0。12
230。0
50.0
0。495
100。60
4.731
18。79
88。89
11。71
0.88
88.358
0.14
88。821
PASS
230。0
50.0
0.375
75.50
3.547
18。93
67.17
8。33
0.87
88。969
0.15
230。0
50.0
0.260
50.60
2.364
19.08
45.11
5。49
0。84
89.143
0.15
230.0
50。0
0。152
25.59
1.183
19。21
22.73
2.86
0。73
88。815
0。91
230。0
50.0
0.084
0。26
0.004
19。34
0。07
0.19
0。01
27.894
0。15
1.3 ACOUSTIC NOISE
Test conditions:
Measurements to determine the AC adapter sound pressure are made using a 1/2” low noise free—field microphone in a inner size with 45(W)×45(D)×65(H) cm^3 Anechoic chamber。
Test equipment:
Anechoic Chamber: Free-Field Acoustics Corp. Lower than 10dB(A) background noise。
B & K Portable Pulse – Type 3560C, Microphone: 4190, Preamplifier: 2669L
Pass/Fail criteria:
The AC Adapter shall produce no human perceivable audible noise (less then 25dB).
Test result: PASS
Back Ground
5。86dB (A)
Specification
No human perceivable audible noise
(20 ~ 20KHz)
Output Load
(A)
Input Voltage / Reading (dB)
115Vac
230Vac
0 A
21。6
16。9
1。58A
18.6
21.0
Max
23。4
22。8
OUTPUT
INPUT
50mm
MIC
ADAPTER
Top (A) side of CASE
The above diagram depicts the microphone of the frontal plane of the microphone to the Adapter and the height of the centerline of the microphone to the Adapter。
Acoustic Noise Test Set-Up
1。4 INRUSH CURRENT
Test condition:
For cold start test at room ambient, the adapter should be off for at least one hour at the test temperature to ensure it is at a uniform temperature before the test is started. Turn on the UUT
at 90 degrees at positive cycle or 270 degrees at negative cycle。 Between each test, the UUT shall be cooled down for at least 3 minutes and the Bulk Cap’s Energy is discharged。
For hot start test at max。 Operating ambient, the adapter should be on and running for at least one hour at the test temperature to ensure it is at a uniform temperature before the test is started。— Repetitive ON/OFF (1Sec. ON/1Sec. OFF for 10 times) cycling of the UUT and turn on at 90 degrees at positive cycle or 270 degrees at negative cycle。 Between each test, the Bulk Cap's Energy shall be discharged.
Test equipment:
Chroma Model 8000 Power Supply Auto Test System
Chroma Model # 6590 9KVA Low Impedance AC Source
Chroma Model # 630X0 DC Load
Tektronix AM503 Current Probe Amplifier
Tektronix A6303 Current Probe
Tektronix TDS-5054 Oscilloscope
Pass/Fail criteria:
The inrush current shall meet the specification requirements。
AC line inrush current shall not damage any components, nor cause the AC line fuse to blow, under any DC load conditions, any ambient temperature, and with any ac line input voltage and frequency.
Test result: PASS
Extended Name = Cold start 25 deg。 ambient; after 1 hour in off stage Vin=90Vac Inrush Current=57.6A. 1).Vin 4).Iin
Extended Name = Cold start 25 deg。 ambient; after 1 hour in off stage Vin=264Vac Inrush Current=138。0A. 1).Vin 4).Iin
Extended Name = Hot start 25 deg. ambient; Repetitive on/off cycle 10 times。 Vin=90Vac Inrush Current=56.4A. 1).Vin 4)。Iin
Extended Name = Hot start 25 deg。 ambient; Repetitive on/off cycle 10 times. Vin=264Vac Inrush Current=138。0A. 1).Vin 4)。Iin
1。5 LINE CYCLE DROPOUT
Test conditions:
The unit is subjected to a dropout of the AC line voltage from 100Vac/50Hz to zero volt for duration which equal to 7mS repeated 10 times with a period of 1 second。 The unit is fully loaded。 Dropout shall occur at any input phase angle。
Test equipment:
Chroma Model 8000 Power Supply Auto Test System
Chroma Model # 6590 9KVA Low Impedance AC Source
Chroma Model # 630X0 DC Load
Tektronix TDS-5054 Oscilloscope
Tektronix P5100 Probe
Pass/Fail criteria:
The unit test need not maintain within regulation but shall not latch off.
Test result: PASS
Extended Name = Dropout; 100Vac/50Hz (0 deg) Dropout 10 ms at Max. Load
1) Vin 2) Vo
Extended Name = Dropout; 100Vac/50Hz (90 deg) Dropout 10 ms at Max. Load
1) Vin 2) Vo
Extended Name = Dropout; 100Vac/50Hz (270 deg) Dropout 10 ms at Max. Load
1) Vin 2) Vo
1。6 BROWNOUT & BROWNOUT RECOVERY
Test conditions:
1. The input voltage decreases from 90Vac/50Hz down to zero in 30 minutes。
2. The input voltage increases from 0Vac up to 90Vac/50Hz in 30 minutes.
Test equipment:
CHROMA 6530 AC SOURCE
CHROMA 630XX DC LOAD
Pass/Fail criteria:
1。 The input voltage below the minimum specifies shall not cause damage to the power supply unit (due to over—heating or otherwise)。
2. The PSU shall recover after an AC power reset.
Test result: PASS
@25°C
1。7 TOTAL HARMONIC DISTORTION
Test conditions:
The power line is distorted (flat-topped) with a total harmonic distortion of up to
10% (100Vac @ 50 Hz with 10 % THD = 90 Vrms).
Test equipment:
Chroma Model 8000 Power Supply Auto Test System
Chroma Model # 65909KVA Low Impedance AC Source
Chroma Model # 630X0 DC Load
Tektronix TDS-5054 Oscilloscope
Tektronix P5100 Probe
Pass/Fail criteria:
The unit test shall meet the specification requirements。
Test result: PASS
Extended Name = Start up operation。
100Vac/50Hz @ Full Load
(1) Vin (2) Vout
Extended Name = Continuous operation。 100Vac/50Hz @ Full Load
(1) Vin (2) Vout
1.8 LINE VOLTAGE SURGE
Test conditions:
While the unit is operating with maximum continuous load, the line voltage is switched to the surge voltage as indicated below:
• 220V