1、完整版)开关电源 测试报告 Item Test Specification Result Page # Remarks A. INPUT CHARACTERIZATION 1。1 Input Current/Power/Efficiency/Power Factor Eff%〉84%;Iin<1.5A PASS 3 1.2 No Load Input Power & Active Mode Efficiency No load (Pin<0.5W); 0。5W load (Pin<1。0W); 1.0W load (Pin<1。7W); 1.5W lo
2、ad (Pin<2.4W); 11.6W load (Pin<14W) 18.7W load (Pin<22W) Average efficiency〉87% PASS 4 1.3 Acoustic Noise <25dB(A) PASS 6 1.4 Inrush Current No damaged(Cold Start) PASS 7 1.5 Line Cycle Dropout No latch off PASS 9 1.6 Brownout & BO Recovery No damaged PASS 11 1。7
3、 Total Harmonic Distortion To start up and no damage PASS 12 1.8 Line Voltage Surge No damaged PASS 13 1.9 Line Voltage Sag No damaged PASS 14 1。10 AC Voltage Dip Immunity No latch off PASS 15 1.11 Harmonic Current EN61000—3-2 class D PASS 16 B。 OUTPUT CHARACTERIZA
4、TION 2.1 Load, Line Cross Regulation 18。55Vdc ~ 19。95Vdc PASS 18 2.2 Peak Load 6。16Asurge load for2mSec; Vo>17Vdc PASS 19 2.3 Ripple and Noise 〈380mVp—p PASS 20 2。4 Dynamic Loading Response 18。55Vdc ~ 19。95Vdc PASS 22 2.5 Output Over / Under Shoot 〈10% PASS 24 2
5、6 Turn On Delay/ Hold up / DC Rise/Fall Time Power—on time<2Sec; Hold up time >5mS; Rise time 〈100mS PASS 26 2.7 Loop Gain > 45 deg. PASS 30 C. PROTECTION 3.1 Short circuit Protection No damage PASS 31 3.2 Over Current Protection >5。7A PASS 33 3.3 Over Voltage Prote
6、ction Vmax:27V PASS 34 D. EMC/SAFETY/ENVIRONMENTAL 4.1 Electric Strength (Hi-Pot) <10mA PASS 36 4.2 Leakage Current 〈50uA@100Vac; 〈100uA@240Vac. PASS 37 4。3 Insulation Resistance (IR) >20MΩ PASS 38 4。4 Electromagnetic Discharge (ESD) IEC61000—4—2 PASS 39 4。5 Elect
7、romagnetic Fast Transient And Burst (EFT) IEC61000-4—4 PASS 41 4。6 AC Surge Immunity (PLD_BI Wave) EN61000—4—5 PASS 43 4.7 Electromagnetic Compatibility Under -6dB PASS 45 Pass / Fail: According to specification 4 hours storage at 0℃, and operating at
8、40℃ N。S。 : Not Specified Test Equipment: TOPNOTCH OTC—2B-N Open Chamber N。T。 : Not Tested CHROMA Series AC Source / DC Load Prepared Checked (TE) Checked (EE) Approved
9、 Page 67 of 67 A. INPUT CHARACTERIZATION 1。1 INPUT CURRENT/POWER/EFFICIENCY/POWER FACTOR Test conditions: The unit is set at maximum load and the input voltage is varied from the minimum to the maximum value. Efficiency is computed an
10、d Power Factor is either computed or measured after 10 minutes warm up at least。 Test equipment: Chroma Model 8000 Power Supply Auto Test System Chroma Model # 6590 9KVA Low Impedance AC Source Chroma Model # 630X0 DC Load Chroma Model # 6630 Power Analyzer Pass/Fail criteria: The unit
11、test shall meet the specification requirements. Test result: PASS @25°C Vin(Vac) Freq(Hz) Iin(A) Pin(W) Vout(V) Pout(W) Pd(W) PF Eff(%) 90.000 47.000 1.283 103。900 18.790 88.853 15。047 0。899 85.518 100。000 50.000 1.128 102。700 18。788 88.877 13。823 0。908 86.540 115
12、000 50。000 0。965 101。600 18。802 88.948 12。652 0。913 87。547 120。000 50。000 0.924 101。500 18。780 88。806 12。694 0。913 87.494 130.000 50。000 0.851 101。200 18。780 88。841 12.359 0。912 87.788 140。000 50。000 0。790 100.900 18.788 88.877 12.023 0.910 88.084 150。000 50.000
13、 0.738 100.800 18。790 88.888 11.912 0。907 88。183 160.000 60.000 0。695 100。700 18.802 88.948 11。752 0.903 88.329 170.000 60。000 0。655 100.400 18。798 88。924 11。476 0.899 88.570 180。000 60.000 0.620 100.500 18.792 88.900 11.600 0。897 88。458 190。000 60.000 0.589 100
14、300 18.785 88.865 11。435 0。893 88。599 200。000 60.000 0。563 100.400 18.788 88.841 11.559 0。888 88。487 210.000 60.000 0.539 100.500 18。785 88。830 11。670 0.884 88。388 220。000 60。000 0.517 100。500 18.788 88。877 11。623 0。879 88.434 230。000 60。000 0.498 100.700 18.792
15、 88.900 11.800 0。875 88。282 240.000 60.000 0.481 100.800 18。795 88.877 11。923 0.870 88。171 250。000 60。000 0。465 100.800 18.805 88。924 11。876 0。865 88.218 264。000 63.000 0.447 101。000 18。790 88.853 12.147 0。853 87。973 @0°C Vin(Vac) Freq(Hz) Iin(A) Pin(W) Vout(V)
16、 Pout(W) Pd(W) PF Eff(%) 90.000 47。000 1.279 103。600 18。870 89。232 14.368 0。899 86。131 100。000 50。000 1.127 102.300 18。868 89.255 13。045 0。907 87.248 115.000 50。000 0。967 101。500 18。875 89。255 12.245 0.911 87。936 120.000 50.000 0.926 101。300 18。868 89.220 12.080
17、 0.909 88。075 130.000 50.000 0.852 101。200 18.880 89.279 11。921 0.909 88。220 140.000 50。000 0。789 100。700 18。862 89.196 11。504 0.909 88.576 150。000 50.000 0。739 100。500 18。882 89。291 11.209 0。905 88。846 160。000 60。000 0.693 100。400 18.870 89。232 11.168 0.902 88.
18、876 170.000 60。000 0.654 100.200 18。868 89.255 10。945 0。899 89。077 180。000 60。000 0。619 100.100 18.868 89.220 10。880 0.896 89。131 190.000 60.000 0。588 100。100 18。868 89.220 10。880 0.893 89.131 200。000 60.000 0。561 100.200 18。872 89.243 10。957 0。889 89。065 210.000
19、 60。000 0。537 100.200 18.880 89.279 10。921 0.885 89.101 220。000 60.000 0。516 100。300 18.882 89.291 11。009 0.880 89。024 230。000 60.000 0。496 100.200 18.885 89.302 10。898 0。875 89。124 240。000 60。000 0。479 100.300 18.885 89。302 10.998 0.870 89。035 250.000 60.000 0。
20、463 100。400 18。878 89。267 11.133 0.864 88.911 264.000 63.000 0。444 100.400 18.875 89.255 11.145 0.853 88。900 @40°C Vin(Vac) Freq(Hz) Iin(A) Pin(W) Vout(V) Pout(W) Pd(W) PF Eff(%) 90.000 47。000 1.276 103。600 18.865 89.172 14.428 0。901 86。074 100.000 50。000 1。1
21、25 102。300 18。860 89。149 13。151 0.907 87.145 115。000 50.000 0.963 101。200 18。868 89。184 12。016 0.911 88.127 120。000 50。000 0.922 101。100 18。872 89.208 11.892 0.912 88。237 130.000 50.000 0。849 100.800 18。880 89.243 11.557 0。910 88.535 140.000 50.000 0.787 100.500
22、 18.882 89。255 11。245 0。909 88。811 150.000 50.000 0。735 100.400 18.870 89。196 11.204 0。907 88.841 160。000 60。000 0。692 100.200 18.862 89。161 11。039 0.903 88.983 170。000 60。000 0。652 100.000 18。862 89.161 10。839 0.899 89.161 180.000 60。000 0.618 100.100 18。868 89.
23、184 10。916 0。896 89.095 190。000 60.000 0。587 99.800 18。875 89。220 10.580 0.893 89.399 200。000 60.000 0.560 99。900 18.885 89。267 10.633 0。889 89。356 210。000 60.000 0.536 100。100 18。885 89。267 10.833 0。885 89.178 220.000 60.000 0。515 99。900 18.882 89。255 10。645 0。
24、880 89.345 230.000 60。000 0.495 100.100 18.878 89。232 10。868 0.875 89。142 240.000 60。000 0.477 100.100 18。870 89。196 10.904 0.870 89.107 250.000 60。000 0。462 100。200 18.865 89.172 11.028 0.864 88。995 264。000 63.000 0.444 100。400 18。872 89。208 11.192 0.854 88.853
25、 1。2 ACTIVE MODE EFFICIENCY & NO LOAD INPUT POWER Test conditions: The unit is set at no load and the rated input voltage for at least 15 minutes. The ambient temperature is set between 15 Deg C to 35 Deg C Test equipment: Chroma Model 8000 Power Supply Auto Test System Chroma Mo
26、del # 65909KVA Low Impedance AC Source Chroma Model # 630X0 DC Load Chroma Model # 6630 Power Analyzer Pass/Fail criteria: The unit test shall meet the specification requirements. Test result: PASS No Load Power Consumption: (Pin〈0。5W) Input Voltage(Vac) Load(W) Iin rms(A) Pow
27、er Factor Pin(W) Vo (Vdc) 115 0.00 0.050 0.010 0。281 19。347 230 0。00 0。084 0。016 0。310 19。347 0.5W Load Power Consumption: (Pin〈1。0W) Input Voltage(Vac) Load(W) Iin rms(A) Power Factor Pin(W) Vo (Vdc) 115 0。5 0.051 0.073 0。432 19.345 230 0。5 0。084 0.029 0。590 19.
28、345 1。0W Load Power Consumption: (Pin〈1.7W) Input Voltage(Vac) Load(W) Iin rms(A) Power Factor Pin(W) Vo (Vdc) 115 1。0 0.053 0。177 1.074 19.343 230 1.0 0.085 0.063 1。240 19.343 1。5W Load Power Consumption: (Pin<2。4W) Input Voltage(Vac) Load(W) Iin rms(A) Power Factor
29、 Pin(W) Vo (Vdc) 115 1。50 0。055 0。273 1。723 19。337 230 1。50 0。086 0。096 1.900 19。337 11。6W Load Power Consumption: (Pin〈14W) Input Voltage(Vac) Load(W) Iin rms(A) Power Factor Pin(W) Vo (Vdc) 115 11.6 0。141 0.806 13。130 19.285 230 11.6 0.109 0。526 13.170 19.270 1
30、8.7W Load Power Consumption: (Pin<22W) Input Voltage(Vac) Load(W) Iin rms(A) Power Factor Pin(W) Vo (Vdc) 115 18。7 0.210 0.863 20。960 19。237 230 18。7 0.136 0.682 21.420 19.237 Active Mode Efficiency: Vin (Vac) Fin (Hz) Iin (A) Pin (W) Iout (A) Vout (V) Pout (W) P
31、d(W) P。F Eff(%) THD(%) Average EFF(%) Result 115。0 60。0 0.963 101。40 4.731 18.78 88.86 12。54 0。91 87。638 0。10 88。820 PASS 115.0 60.0 0.724 75.90 3。547 18。93 67.15 8.75 0。91 88。465 0。10 115.0 60.0 0。484 50.30 2.364 19.07 45。09 5。21 0。90 89.651 0.11 115。0 60。0
32、 0。251 25。35 1.181 19.21 22.69 2.66 0.88 89.526 0。12 115.0 60.0 0.050 0.17 0.002 19。34 0。04 0。13 0。03 21.714 0。12 230。0 50.0 0。495 100。60 4.731 18。79 88。89 11。71 0.88 88.358 0.14 88。821 PASS 230。0 50.0 0.375 75.50 3.547 18。93 67.17 8。33 0.87 88。969 0.15 2
33、30。0 50.0 0.260 50.60 2.364 19.08 45.11 5。49 0。84 89.143 0.15 230.0 50。0 0。152 25.59 1.183 19。21 22.73 2.86 0。73 88。815 0。91 230。0 50.0 0.084 0。26 0.004 19。34 0。07 0.19 0。01 27.894 0。15 1.3 ACOUSTIC NOISE Test conditions: Measurements to determine the AC
34、 adapter sound pressure are made using a 1/2” low noise free—field microphone in a inner size with 45(W)×45(D)×65(H) cm^3 Anechoic chamber。 Test equipment: Anechoic Chamber: Free-Field Acoustics Corp. Lower than 10dB(A) background noise。 B & K Portable Pulse – Type 3560C, Microphone: 4190, Pre
35、amplifier: 2669L Pass/Fail criteria: The AC Adapter shall produce no human perceivable audible noise (less then 25dB). Test result: PASS Back Ground 5。86dB (A) Specification No human perceivable audible noise (20 ~ 20KHz) Output Load (A) Input Voltage / Reading (dB) 115V
36、ac 230Vac 0 A 21。6 16。9 1。58A 18.6 21.0 Max 23。4 22。8 OUTPUT INPUT 50mm MIC ADAPTER Top (A) side of CASE The above diagram depicts the microphone of the frontal plane of the microphone to the Adapter and the height of the centerline of the microphone to
37、 the Adapter。 Acoustic Noise Test Set-Up 1。4 INRUSH CURRENT Test condition: For cold start test at room ambient, the adapter should be off for at least one hour at the test temperature to ensure it is at a uniform temperature before the test is started. Turn on the UUT at 90 degrees at
38、positive cycle or 270 degrees at negative cycle。 Between each test, the UUT shall be cooled down for at least 3 minutes and the Bulk Cap’s Energy is discharged。 For hot start test at max。 Operating ambient, the adapter should be on and running for at least one hour at the test temperature to ensu
39、re it is at a uniform temperature before the test is started。— Repetitive ON/OFF (1Sec. ON/1Sec. OFF for 10 times) cycling of the UUT and turn on at 90 degrees at positive cycle or 270 degrees at negative cycle。 Between each test, the Bulk Cap's Energy shall be discharged. Test equipment: Chrom
40、a Model 8000 Power Supply Auto Test System Chroma Model # 6590 9KVA Low Impedance AC Source Chroma Model # 630X0 DC Load Tektronix AM503 Current Probe Amplifier Tektronix A6303 Current Probe Tektronix TDS-5054 Oscilloscope Pass/Fail criteria: The inrush current shall meet the specificatio
41、n requirements。 AC line inrush current shall not damage any components, nor cause the AC line fuse to blow, under any DC load conditions, any ambient temperature, and with any ac line input voltage and frequency. Test result: PASS Extended Name = Cold start 25 deg。 ambient; after 1 hou
42、r in off stage Vin=90Vac Inrush Current=57.6A. 1).Vin 4).Iin Extended Name = Cold start 25 deg。 ambient; after 1 hour in off stage Vin=264Vac Inrush Current=138。0A. 1).Vin 4).Iin Extended Name = Hot start 25 deg. ambient; Repetitive on/off cycle 10 times。 Vin=90Vac Inrush Current=56.4A.
43、1).Vin 4)。Iin Extended Name = Hot start 25 deg。 ambient; Repetitive on/off cycle 10 times. Vin=264Vac Inrush Current=138。0A. 1).Vin 4)。Iin 1。5 LINE CYCLE DROPOUT Test conditions: The unit is subjected to a dropout of the AC line voltage from 100Vac/50Hz to zero volt for duration whi
44、ch equal to 7mS repeated 10 times with a period of 1 second。 The unit is fully loaded。 Dropout shall occur at any input phase angle。 Test equipment: Chroma Model 8000 Power Supply Auto Test System Chroma Model # 6590 9KVA Low Impedance AC Source Chroma Model # 630X0 DC Load Tektronix TDS-50
45、54 Oscilloscope Tektronix P5100 Probe Pass/Fail criteria: The unit test need not maintain within regulation but shall not latch off. Test result: PASS Extended Name = Dropout; 100Vac/50Hz (0 deg) Dropout 10 ms at Max. Load 1) Vin 2) Vo Extended Name = Dropout; 100Vac/50Hz (90 deg)
46、 Dropout 10 ms at Max. Load 1) Vin 2) Vo Extended Name = Dropout; 100Vac/50Hz (270 deg) Dropout 10 ms at Max. Load 1) Vin 2) Vo 1。6 BROWNOUT & BROWNOUT RECOVERY Test conditions: 1. The input voltage decreases from 90Vac/50Hz down to zero in 30 minutes。 2. The input voltage increases
47、from 0Vac up to 90Vac/50Hz in 30 minutes. Test equipment: CHROMA 6530 AC SOURCE CHROMA 630XX DC LOAD Pass/Fail criteria: 1。 The input voltage below the minimum specifies shall not cause damage to the power supply unit (due to over—heating or otherwise)。 2. The PSU shall recover after an
48、AC power reset. Test result: PASS @25°C 1。7 TOTAL HARMONIC DISTORTION Test conditions: The power line is distorted (flat-topped) with a total harmonic distortion of up to 10% (100Vac @ 50 Hz with 10 % THD = 90 Vrms). Test equipment: Chroma Model 8000 Power Supply Auto Test Syst
49、em Chroma Model # 65909KVA Low Impedance AC Source Chroma Model # 630X0 DC Load Tektronix TDS-5054 Oscilloscope Tektronix P5100 Probe Pass/Fail criteria: The unit test shall meet the specification requirements。 Test result: PASS Extended Name = Start up operation。 100Vac/50Hz @
50、Full Load (1) Vin (2) Vout Extended Name = Continuous operation。 100Vac/50Hz @ Full Load (1) Vin (2) Vout 1.8 LINE VOLTAGE SURGE Test conditions: While the unit is operating with maximum continuous load, the line voltage is switched to the surge voltage as indicated below: • 220V