资源描述
特变电工新能源控制器和逆变器系列产品
1.小功率充电控制器系列 Small Power Charge Controller Series
型 号 Type
XNY-TZ
12/24 10BⅡ
XNY-TZ
12/24 20BⅡ
XNY-TZ
12/24 30BⅡ
XNY-TZ
12/24 40BⅡ
充
电
输
入
Charge Input
组件最大开路电压
Maximum Open Circuit Voltage of Solar Module
25V / 50V
额定输入电流
Rated Input Current
10 A
20 A
30 A
40 A
蓄
电
池
Storage Battery
标称电压
Nominal Voltage
12V / 24V
浮充电压
Float Voltage
13.7V / 27.4V
过充电压
Over Charge Voltage
14.3V / 28.6V
欠压电压
Lack of Voltage
10.8V / 21/6V
直
流
输
出
DC Output
输出电压
Output Voltage
10.8-14.3V / 22.0-28.6V
输出最大电流
Maximum Output Current
20A
40A
提示关断电压
Prompt for cutting voltage
11.5V / 23.0V
欠压关断
Cutting for lack of voltage
10.8V / 21.6V
欠压恢复
LV resumption
13.0V / 26.0V
显示
Display
LED指示 indication
系统运行、欠压提示、欠压保护、过充保护、负载保护、短路保护
Systematic operation, LV indication, LV protection, over charge protection, loads protection, short circuit protection
液晶显示(可选)
LCD display
(optional)
充电电压、充电电流、蓄电池电压、蓄电池容量、输出电流
Charge voltage, charge current, voltage of storage battery, capacity of storage battery, output current
报
警
保
护
Alarm Protections
输入反接保护
Input reverse connection protection
有Yes
输出短路保护
Output short circuit protection
有Yes
蓄电池欠压保护
LV protection for storage battery
有Yes
蓄电池反接保护
Reverse connection protection for storage battery
有Yes
其 它
项
Other Items
防护等级
Defend rank
符合DIN EN60529规定 IP22或IP65标准
In compliance with regulations of DIN EN60529 and standards of IP22 or IP65
充电模式
Charge mode
PWM脉宽调制,恒流-恒压模式,蓄电池自动维护功能
PWM ,constant current—constant voltage, function of automatic protection for storage battery
散热方式
Radiating mode
自冷 Automatic cooling
工作模式
Working mode
普通控制器、光控开+时控关、时控开+光控关
General controller, lighting for on+ timing for off, timing for on + lighting for on
自耗电
Self electricity consumption
< 10 mA
< 15mA
环
境
Environment
使用环境温度
Environmental temperature
-10℃ --45℃
使用环境湿度 Ambient humidity
0--90%,不结露 no dew
海拔
Altitude
≤4500m
体积
Volume
长*宽*高
Length*
Width*
Height
120*90*45
180*110*55
180*110*55
180*110*55
2.小功率户用电源系列 Small Power Electrical Source Series for Home Use
型号 Type
XNY-TNX 12/24 300 L III型
XNY-TNX 12/24 500 L III型
充
电
输
入
Charge Input
组件最大开路电压
Maximum Open Circuit Voltage of Solar Module
25V / 50V
额定输入电流
Rated Input Current
25A/12.5A
50A/25A
蓄
电
池
Storage Battery
标称电压
Nominal Voltage
12V / 24V
浮充电压
Float Voltage
13.7V / 27.4V
过充电压
Over Charge Voltage
14.3V / 28.6V
欠压电压
Lack of Voltage
10.8V / 21/6V
直
流
输
出
DC Output
输出电压
Output Voltage
10.8-14.3V / 22.0-28.6V
输出最大电流
Maximum Output Current
20A
40A
欠压关断
Cutting for lack of voltage
10.8V / 21.6V
欠压恢复
LV resumption
13.0V / 26.0V
交
流
输
出
AC Output
输出电压
Output Voltage
AC220V±10%
输出波形
Output Wave Shape
修正正弦波
Modified Sine Wave
输出频率
Output Frequency
50±1 Hz
额定输出功率
Rated Output Power
300W
600W
转换效率
Conversion Efficiency
>94%
显示
Display
LED显示
充电指示、直流负载输出、欠压、过压等状态指示.
Charge Indication, DC Load Output, Lack of Voltage, Over Voltage and other status indication
环境
Environment
温度
Temperature
-10℃ —45℃
湿度
Humidity
0—90%,不结露 no dew
海拔
Altitude
≤4500m
外形
Appearance
参考重量
Reference Weight
30Kg(不带蓄电池)Not including Storage Battery
参考尺寸
Reference Dimension
430*320*160
3.小功率逆变器系列 Small Power Inverter Series
型号 Type
XNY-NS 48V 1K B I
XNY-NS 24V 600 B I
直流输入
DC Input
额定输入电压
Rated input voltage
48V
24V
额定输入电流
Rated input current
19A
23A
输入直流电压允许范围
Allowed input DC voltage scope
42.7V—58V
21.3V—29V
开机电压范围
Voltage scope of starting up equipments
47V—58V
23.5V—29V
欠压告警点
LV alarm point
46V
23V
过压告警点
OV alarm point
54V
27V
反灌杂音电流
Anti-noise current
≤10%
≤10%
交
流
输
出
AC Output
额定容量(VA)
Rated capacity
1000VA
600VA
额定输出功率(W)
Rated output power
800W
500W
额定输出电压及频率
Rated output voltage and frequency
220Vac,50Hz
220Vac,50Hz
额定输出电流(A)
Rated output current
4.5A
2.7A
输出电压精度(Vac)
Output voltage precision
220±5%
输出频率精度(Hz)
Output frequency precision
50±1%
波形失真率(THD)
(线性负载)
Rate of wave distortion
(Linearity loads)
≤2%
动态响应时间
(负载0←→100%)
Dynamic response speed
5S
过载能力
Overload capability
120%,2分钟 two minutes
150%, 15秒钟 15seconds
逆变效率
(80%阻性负载)
Inverting efficiency
80% resistive loads
≥90%
使用环境温度
Ambient temperature
-10℃ -- +40℃
湿度
Humidity
0--90%,不结露 no dew
使用海拔(m)
Altitude
≤4500
保
护
功
能
Protection Function
输入欠压保护
Input LV protection
输入过压保护
Input OV protection
输出过载保护
Output overload protection
输出短路保护
Output Short Circuit Protection
4. -48V通讯电源系列 48V Communication Power Supply Series
型号 Type
XNY-CT
48 – 120
XNY-CT
48 – 160
XNY-CT
48 -200
XNY-CT
48 -300
输
入
特
性
Input Characteristics
输入电压范围
Input voltage scope
0~100V
输入方式
Input mode
多路 many loops
额定输入电压
Rated input voltage
-68V
蓄电池电压级别 voltage rank of storage battery
-48V
控
制
器
性
能
Performances of charger
太阳能输入接口 Solar input terminal
3路 3loops
4路 4loops
5路 5loops
8路 8loops
额定充电电流
Rated charge current
120A
160A
200A
300A
单路额定充电电流
Rated charge current of single loop
40A
欠压关断
Cutting for lack of voltage
-43.2V(-43.0—-47.0V constant adjustable)
欠压恢复
LV resumption
-53.0V(-52.0—-54.4V constant adjustable)
浮充电压
Float voltage
-56.0V(-52.0—-56.0V constant adjustable)
均充电压
Average voltage
-58.0V(-54.0—-58.0V constant adjustable)
高压关断
Cutting for high-voltage
-60.0V(-58.0—-62.0V constant adjustable)
温度补偿系数
Temperature compensation coefficient
-4mV/cell/℃(-1—-5mV/cell/℃ constant adjustable)
放电输出接口
Discharge output terminal
2circuits路(每路最大60A)Max. 60A each circuit
静态工作电流
Static working current
≤60mA
显示
Display
LCD显示display
充电电压、充电电流、电池电压、电池容量、输出电压、输出电流
Charge voltage, charge current, voltage of storage battery, capacity of storage battery, output voltage, output current
通信
Communication
RS422/RS485
历史数据存储100天,参数可修改,符合RS422/RS485标准通信接口协议。100 days historic data memory, parameters can be adjusted, in compliance with RS422/RS485 standard communication terminal protocol
报
警
保
护
Alarm Protection
放电欠压保护
Discharge LV protection
有Yes
充电短路保护
Charge short circuit protection
有Yes
充电过压保护
Charge OV protection
有Yes
内部故障保护
Internal trouble protection
有Yes
输入防雷保护
Input anti-thunder protection
符合通信电源设备相关标准
In accordance with relevant standards of communication power supply equipment
环
境
Environment
散热方式
Radiating mode
自然冷却
Natural cooling
温度
Temperature
-40℃-- +60 ℃
海拔高度
Altitude
≤6000m
湿度
Humidity
≤95%(25 ℃)
5. +24V通讯电源系列 +24V Communication Power Supply Series
型号 Type
XNY-CT
24 – 40
XNY-CT
24 –80
XNY-CT
24 -120
XNY-CT
24 -200
输
入
特
性
Input Characteristics
输入电压范围
Input voltage scope
0~100V
输入方式
Input mode
多路 many loops
额定输入电压
Rated input voltage
34V
蓄电池电压级别 voltage rank of storage battery
24V
控
制
器
性
能
Performances of charger
太阳能输入接口
Solar input terminal
1路 1loop
2路2 loops
3路3loops
5路5loops
额定充电电流
Rated charge current
40A
80A
120A
200A
单路额定充电电流
Rated charge current of Single loop
40A
欠压关断
Cutting for lack of voltage
21.6V(21.5—23.5V constant adjustable)
欠压恢复
LV resumption
26.5V(26.0—27.2V constant adjustable)
浮充电压
Float voltage
28.0V(26.0—28.0V constant adjustable)
均充电压
Average voltage
29.0V(27.0—29.0V constant adjustable)
高压关断
Cutting for high-voltage
30.0V(29.0—31.0V constant adjustable)
温度补偿系数
Temperature compensation coefficient
-4mV/cell/℃(-1—-5mV/cell/℃constant adjustable)
放电输出接口
Discharge output terminal
2 路(每路最大60A)
2 loops ,Max. 60A each loop
静态工作电流 static working current
≤60mA
显示
Display
LCD显示
LCD display
充电电压、充电电流、电池电压、电池容量、输出电压、输出电流
Charge voltage, charge current, voltage of storage battery, capacity of storage battery, output voltage, output current
通信
Communication
RS422/RS485
历史数据存储100天,参数可修改,符合RS422/RS485标准通信接口协议。100 days historic data memory, parameters can be adjusted, in compliance with RS422/RS485 standard communication terminal protocol
报
警
保
护
Alarm Protection
放电欠压保护
Discharge LV protection
有Yes
充电短路保护
Charge short circuit protection
有Yes
充电过压保护
Charge OV protection
有Yes
内部故障保护
Internal trouble protection
有Yes
输入防雷保护
Input lightning-proof protection
符合通信电源设备相关标准
In accordance with relevant standards of communication power supply equipment
环
境
Environment
散热方式
radiating mode
自然冷却
Natural cooling
温度
Temperature
-40℃ -- +60 ℃
海拔高度
Altitude
≤6000m
湿度
Humidity
≤95%(25 ℃)
6.大功率充电逆变一体机 large power charger and inverter system
型号 Type
XNY-NK3S480
/240 30k
XNY-NK3S480 /240 50k
XNY-NK3S480 /240 100K
XNY-NK3S480 150K
直
流
输
入
DC Input
额定电压
Rated voltage
480VDC/240V DC
480V DC
最大PV电压
Max. PV voltage
800V / 400V
800V
欠压(LV)
Lack of voltage
432V / 216V
432V
过压(OV)
Over voltage
574V / 282V
574V
欠压恢复
Lack of voltage resumption
500V / 250V
500V
额定充电电流
Rated charge current
65A / 130A
120A /240A
240A / 480A
360A
交
流
输
出
AC Output
输出电压
Output voltage
380VAC±1%
输出频率
Output frequency
50Hz(60 Hz)±0.5%
输出波形
Output wave
纯正弦波
Pure sine wave
过载能力
Over-load capability
120% 过载3分钟,150% overload过载10秒seconds
overload 3 minutes for 120% output , overload 10seconds for 150% output.
额定输出功率
Rated output power
30KVA
50KVA
100KVA
150KVA
最大转换效率
Max. conversion efficiency
96%
96%
96%
97%
和谐波含量
Harmonious wave content
<3%
<3%
<3%
<3%
显示
Display
本地显示
Local display
蓄电池电压、蓄电池电流、输出电压、输出电流
Voltage of storage battery, current of storage battery, output voltage, output current
本地指示
Local indication
系统运行、蓄电池偏压,负载过流状态。
Systematic operation, voltage bias of storage battery, over current status of loads
远程显示
Long distance display
电池电压、电池电流、电池温度、电池容量、输出电压、输出电流
Voltage of storage battery, current of storage battery, temperature of storage battery, capacity of storage battery, output voltage, output current
通讯
Communication
通讯接口
Communication terminal
标准RS232/RS485或CAN总线,可选MODEM,GPRS,以太网模块
Standard RS232/RS485 or CAN bus, MODEM,GPRS, Ethernet network mode optional
保
护
功
能
Protection functions
过载保护
Overload protection
红灯亮,输出保护,手动恢复
Red Light is on, output protection, man-made resumption
欠压保护
LV protection
红灯亮,蜂鸣器间歇工作,输出保护,自动恢复
Red Light is on, buzzer working intermittently, output protection, automatic resumption
过压保护
OV protection
红灯亮,输出保护,自动恢复
Red Light is on, output protection, automatic resumption
短路保护
Short circuit protection
有Yes
散热方式
Radiating mode
风扇强冷 strong and cold fan
环
境
Environment
环境温度
Ambient temperature
-25℃~+60℃
环境湿度
Ambient humidity
0-90%
防护等级
Defend rank
IP20
海拔
Altitude
≤4500m
7.单相并网逆变电源
Single Phase Grid-connected Inverting Power Supply
型号 Type
XNY-GC-3K
XNY-GC-5K
XNY-GC-10K
输
入
参
数
Input parameters
额定容量
Rated Capacity
3kVA
5kVA
10kVA
建议组件功率
Proposed/advised power of solar module
3.3kW
5.5kW
11kW
输入直流电压范围
Input DC voltage scope
200V-600V DC
输入电压范围MPPT
Input voltage scope MPPT
250V-550V
最大阵列输入电流
Max. array input current
12 A
20 A
40 A
过压保护
Over voltage protection
是Yes
接地故障保护
Earthing trouble protection
是Yes
过热保护
Overheat protection
是Yes
输
出
参
数
Output parameters
最大交流输出功率
Max. AC output power
3000 W
5000 W
10000 W
交流输出电流
AC output current
14A
23A
45A
总电流波形畸变率
Aberration ratio of General current wave
<3 %
输出电压等级
Output voltage rank
单相220V
允许电网电压范围
Allowed grid voltage scope
180-260 V AC
允许电网频率范围
Allowed grid frequency scope
48-52 Hz
功率因数
Power factor
0.99
最大效率Max. power
>96 %
欧洲效率
EU efficiency
>95 %
通讯
接口
Communication terminal
标准RS232/RS485或CAN总线[可选MODEM,GPRS,以太网模块]
Standard RS232/RS485 or CAN general bus[ MODEM, GPRS, Ethernet network mode optional]
电气绝缘性能
Electric insulated performances
直流输入对地
1500VAC,一分钟 one minute 1500VAC
直流与交流之间 between DC and AC
1500VAC,一分钟 one minute 1500VAC
环
境
Environment
环境温度
Ambient temperature
-25℃~+60℃
环境湿度
Ambient humidity
0-90%
防护等级
Defend rank
IP20
海拔
Altitude
≤4500m
8.三相并网逆变器 3 phases Grid-connected Inverter
型号 type
XNY-GC-10K 3
XNY-GC-30K 3
XNY-GC-50K 3
输
入
参
数
Input Parameters
额定容量
Rated Capacity
10kVA
30kVA
50kVA
建议组件功率
Proposed/Advised power of solar module
11kW
33kW
55kW
输入直流电压范围
Input DC voltage scope
300V-800V DC
MPPT电压范围
MPPT voltage scope
350V-700V
最大阵列输入电流
Max. array input current
30A
90 A
150A
过压保护
Over voltage protection
是 Yes
接地故障保护
Earthing trouble protection
是Yes
过热保护
Overheat protection
是Yes
输
出
参
数
Output Parameters
最大交流输出功率
Max. AC output power
10kW
30kW
50kW
交流输出电流
AC output current
15A
45A
75A
总电流波形畸变率
Aberration ratio of General current wave
< 3%
输出电压等级
Output voltage rank
3相380V
3 phases 380V
允许电网电压范围
Allowed grid voltage scope
330-430VAC
允许电网频率范围
Allowed grid frequency scope
48-52 Hz
可调整交流频率范围
Adjustable AC frequency scope
45.5-54.5 Hz
功率因数
Efficiency factor
>0.99
最大效率
Max.efficiency
>96.5 %
欧洲效率
EU efficiency
>95.5 %
显示
Display
本地显示
Local display
输出电压、输出电流、输出频率、发电统计数据、环境参数
Output voltage, Output current, Output frequency, Electricity generation statistics data, Environmental parameter
本地指示
Local indication
系统运行、待机、故障状态。
Systematic operation, Standby ,Trouble Status
通讯
接口
Communication Terminal
标准RS232/RS485或CAN总线[电力载波,GPRS,以太网模块]
Standard RS232/RS485 or CAN general bus [ carrier wave of electric power, GPRS, Ethernet network mode]
电气绝缘性能
Electric Insulated Performance
直流输入对地 DC input earth
1500VAC,一分钟
one minute 1500VAC
直流与交流之间 between DC and AC
1500VAC,一分钟
one minute 1500VAC
环
境
Environment
环境温度
Ambient temperature
-25℃~+60℃
环境湿度
Ambient humidity
0-90%
防护等级
Defend rank
IP20
海拔
Altitude
≤4500m
型号 type
XNY-GC-100K3
XNY-GC-250K3
输
入
参
数
Input Parameters
额定容量
Rated Capacity
100kVA
250kVA
建议组建功率
Proposed power of solar module
110kW
275kW
输入直流电压范围
Input DC voltage scope
400V-900V DC
MPPT电压范围
MPPT voltage scope
450V-850V
最大阵列输入电流
Max. Array Input Current
220 A
450 A
过压保护
Over voltage protection
是 Yes
接地故障保护
Earthing trouble protection
是Yes
过热保护
Overheat protection
是Yes
输
出
参
数
Output Parameters
最大交流输出功率
Max. AC Output Power
100kW
250kW
交流输出电流
AC Output Current
150A
375A
总电流波形
畸变率
Aberration ratio of General current wave
< 3 %
输出电压等级
Output voltage rank
3 phases380V
允许电网电压范围
Allowed grid voltage scope
330-430VAC
允许电网频率范围
Allowed grid frequency scope
48-52 Hz
功率因数
Power factor
>0.99
最大效率
Max. efficiency
>97 %
欧洲效率
EU efficiency
>96 %
显示 Display
本地显示
Local indication
输出电压、输出电流、输出频率、发电统计数据、环境参数
Output voltage, Output current, Output frequency, Electricity generation statistics data, Environmental parameter
本地指示
Local Indication
系统运行、待机、故障状态。Systematic operation, Standby, Trouble Status
电气绝缘性能
Electric Insulated Performance
直流输入对地
DC Input Earth
1