8.1 PH值测定(电位法) ······························(5)
8.2 电导率测定(电导仪法)····························(8)
8.3 浊度测定(浊度仪器法)····························(11)
8.4 悬浮物测定(重量法)······························(13)
8.5总硬度测定(EDTA络合滴定法)······················(14)
8.6 钙离子测定(EDTA络合滴定法)·····················(17)
A 按中石化法·······································(17)
B 按国家标准法·········································(18)
8.7 总碱度测定(指示剂法)····························(20)
A 按国家标准法·········································(20)
B 按中石化法·······································(22)
8.8 氯离子测定······································(25)
甲 硝酸银滴定法···································(25)
乙 硝酸汞滴定法···································(26)
8.9 铁离子测定(邻菲罗啉分光光度法)·················(28)
8.10 总磷测定(钼酸铵分光光度法)····················(30)
A法········································(30)
B法·······································(32)
8.11 游离氯和总氯测定(DPG分光光度法)···············(39)
8.12 锌离子测定(EDTA络合滴定法)····················(43)
8.13 硫酸根测定(EDTA滴定法)························(45)
8.14 铜离子测定(二乙基二硫代氨基甲酸钠分光光度法)··(48)
8.15 硫化物测定(亚甲基兰分光光度法)················(51)
8.16油含量测定(红外油分分析仪法)··················(53)
8.17氨氮测定(纳氏试剂比色法)·······················(55)
8.18 异养菌测定(标准平皿计数法)····················(57)
8.19 COD化学需氧量测定(重铬酸钾法)·················(62)
8.20 二氧化硅测定(硅钼黄还原分光光度法)············(64)
8.21 硝酸根测定(2,6-二甲基苯酚分光光度法)·········(65)
8.22 亚硝酸根测定(盐酸α-萘胺分光光度法)···········(68)
9.0.生产过程危险源点··································(71)
10.0生产安全作业要求·································(71)
11.0相关文件·········································(71)
12.0相关统计·········································(72)
水质分析操作规程
1.0 目标
制订该操作规程目标是规范工业水质测定方法,为水处理工作提供正确数据;规范水质分析操作人员行为及设备完好和正常运转。
2.0 适用范围
本操作规程适适用于水质分析各岗位,各岗位全部操作人员必需严格根据本操作规程操作。
3.0 管理要求
分析人员必需经过对应化学分析方面培训,掌握样品采集、分析、仪器校准、使用、分析用化学品配制和管理等相关基础知识。
4.0 职责
4.1.班组长负责实施安全、清洁生产各项作业要求。
4.2.安全员负责安全、清洁生产检验、监督、考评。
4.3.本工种操作人员负责文件实施。
4.4.本工种操作人员需严格实施。
5.0 作业前准备
5.1.召开班前会议,做好交接及分工。
5.2.生产作业时必需穿戴好劳动保护用具。
5.2.1.工作服全部扣子,包含排扣、袖扣必需扣好。
5.2.2.劳保鞋必需将鞋带系紧。
5.2.3.白大褂穿戴整齐。
6.0 水质分析工作步骤
检验设备仪器是否完好 按要求采样 样品分析 原始数据统计 数据处理 出分析汇报 复核人员对数据复核 汇报上交
7.0 水质分析方法通常要求
本要求适适用于“冷却水化学处理水质分析方法”中各方法。在制订和实施“冷却水化学处理水质和污垢分析方法”时应遵守本要求。
7.1 方法中所列试剂,除特殊要求外,均指符合国家标准(GB)或专业标准(部标准)分析纯试剂,作基准者应采取基准试剂。
7.2 方法中所用水,除另有要求外,均系指蒸馏水或相同级纯度水。
7.3 方法中所用溶液,除另有说明外,均指水溶液。
7.4 由固体试剂配制非标准溶液均以%(m/V)表示,即称取一定量固体试剂溶于溶剂中,并以同一溶剂稀释至100mL混匀而成。
7.5 由液体试剂配制稀水溶液,均应以浓溶液体积加水体积表示,如1+3硫酸溶液系指1体积浓酸加到3体积水中混合配制而成。
7.6 方法中所载“在水浴上加热”,除另有要求外,系指在沸腾水浴上加热。
7.7 方法中所载“灼烧或烘干至恒重”,如无特殊说明,均指系灼烧或烘干,并于干燥器中冷却至室温后称重,反复进行至最终两次称量之差小于0.0003g,即为恒重,取最终一次重量作为计算依据。
7.8 方法中所载“干过滤”,系指用干滤纸、干漏斗将溶液过滤,滤液搜集于干燥容器中,干过滤均应弃去初滤液。
7.9 当方法中所表示数量前标有“约”时,系指方法中所记载量为近似值或用简易计量器具所量取量。
7.10 当方法中有称准至××××时,系指正确到方法中所要求精度。
7.11 方法中有项目并列两个以上分析方法,可依据水质含量范围和具体条件选择。
7.12 方法中需用到仪器均包含试验室基础仪器和设备。
8.0水质分析方法
8.1 PH值测定(电位法)
本方法采取国家标准 GB 15893.2-1995《工业循环冷却水中PH值测定》
8.1.1 原理
将要求指示电极和参比电极浸入同一被测溶液中,成一原电池,其电动势和溶液PH值相关。经过测量原电池电动势即可得出溶液PH值。
8.1.2 试剂
8.1.2.1 草酸盐标准缓冲溶液:c[KH3(C2O4)2·2H2O]=0.05mol/L。
称取12.61g四草酸钾(GB 6855)溶于无二氧化碳水中,稀释至1000ml。
8.1.2.2 酒石酸盐标准缓冲溶液:饱和溶液。
在25℃下,用无二氧化碳水溶解过量(约75g/L)酒石酸氢钾并猛烈振摇以制备其饱和溶液。
8.1.2.3 苯二甲酸盐标准缓冲溶液:c(C6H4CO2K)=0.05mol/L。
称取10.24g预先于110±5℃干燥1h苯二甲酸氢钾(GB 6857),溶于无二氧化碳水中,稀释至1000ml。
8.1.2.4 磷酸盐标准缓冲溶液:c(KH2PO4)=0.025mol/L;c(Na2HPO4)=0.025mol/L。
称取3.39g磷酸二氢钾(GB 6853)和3.53g磷酸二氢钠(GB 6854),溶于无二氧化碳水中,稀释至1000ml。磷酸二氢钾和3.53g磷酸二氢钠需预先在120±10℃干燥2h。
8.1.2.5 硼酸盐标准缓冲溶液:c(Na2B4O7·10H2O)=0.01mol/L。
称取3.80g十水合四硼酸钠(GB 6856),溶于无二氧化碳水中,稀释至1000ml。
8.1.2.6氢氧化钙标准缓冲溶液:饱和溶液。
在25℃时,用无二氧化碳水制备氢氧化钙饱和溶液。存放时应预防空气中二氧化碳进入。一旦出现混浊,应弃去重配。
8.1.2.7各标准缓冲溶液PH值见表1。
温度℃
草酸盐标准缓冲溶液
苯二甲酸盐标准缓冲液
酒石酸盐标准缓冲溶液
磷酸盐标准缓冲溶液
硼酸盐标准缓冲溶液
氢氧化钙标准缓冲溶液
0
1.67
4.00
/
6.98
9.46
13.42
5
1.67
4.00
/
6.95
9.39
13.21
10
1.67
4.00
/
6.92
9.33
13.00
15
1.67
4.00
/
6.90
9.28
12.81
20
1.68
4.00
/
6.88
9.23
12.63
25
1.68
4.01
3.56
6.86
9.18
12.45
30
1.69
4.01
3.55
6.85
9.14
12.29
35
1.69
4.02
3.55
6.84
9.11
12.13
40
1.69
4.04
3.55
6.84
9.07
11.98
8.1.3 仪器
8.1.3.1 酸度计:分度值为0.02pH单位。
8.1.3.2 玻璃指示电极
使用前须在水中浸泡24h以上,使用后应立即清洗并于水中保留。若玻璃电极表面污染,可先用肥皂或洗涤剂洗。然后用水淋洗几次,再浸入盐酸(1+9)溶液中,以除去污物。最终用水洗净,浸入水中备用。
8.1.3.3 饱和甘汞参比电极
使用时电极上端小孔橡皮塞必需拨出,以预防产生扩散电位影响测定结果。电极内氯化钾溶液中不能有气泡,以预防断路。溶液中应保持有少许氯化钾晶体,以确保氯化钾溶液饱和。注意电极液络部不被沾污或堵塞,并保持液络部合适渗出流速。
8.1.3.4 复合电极
可替换玻璃指示电极和饱和甘汞参比电极使用。使用前须在水中浸泡24h以上,使用后应立即清洗并浸于水中保留。
8.1.4分析步骤
8.1.4.1 调试:按酸度计说明书调试仪器。
8.1.4.2 定位
按8.1.2所述,分别制备两种标准缓冲溶液,使其中一个PH值大于并靠近试样PH值,另一个小于并靠近试样PH值。调整PH计温度赔偿旋钮至所测试样温度值。根据附表1所标明数据,依次校正标准缓冲溶液在该温度下pH值。反复校正直到其读数和标准缓冲溶液PH值相差不超出0.02PH单位。
8.1.4.3 测定
用分度值为1℃温度计测量试样温度。把试样放入一个洁净烧杯中,并将酸度计温度赔偿旋钮调至所测试样温度。浸入电极,摇匀,测定。
8.1.4.4 分析结果表述
8.1.4.4.1 汇报被测试样温度时应正确到1℃。
8.1.4.4.2 汇报被测试样PH值时应正确到0.1PH单位。
8.1.5 许可差
取平行测定结果算术平均值为测定结果,平行测定结果绝对差值小于0.1PH单位。
8.2 电导率测定(电导仪法)
本方法采取国家标准 GB/T 6908-《锅炉用水和冷却水分析方法 电导率测定》
8.2.1原理
溶解于水酸、碱、盐电解质,在溶液中解离成正、负离子,使电解质溶液含有导电能力,其导电能力大小用电导率表示。
8.2.2 试剂
8.2.2.1氯化钾标准溶:c(KCl)=1 mol/L。
称取在105℃干燥2h优级纯氯化钾(或基准试剂)74.246g,用新制备二级试剂水溶解后移入1000ml容量瓶中,在(20士2)℃下稀释至刻度,混匀。放人聚乙烯塑料瓶或硬质玻璃瓶中,密封保留。
8.2.2.2氯化钾标准溶液:c(KCl)=0.1mol/L。
称取在105℃干燥2h优级纯氯化钾(或基准试剂)7.4365g,用新制备二级试剂水溶解后移入1000ml容量瓶中,在(20士2)℃下稀释至刻度,混匀。放人聚乙烯塑料瓶或硬质玻璃瓶中,密封保留。
8.2.2.3氯化钾标准溶液:c(KCl)=0.01 mol/L。
称取在105℃干燥2h优级纯氯化钾(或基准试剂)0.7440g,用新制备二级试剂水溶解后移入1000ml容量瓶中,在(20士2)℃下稀释至刻度,混匀。放人聚乙烯塑料瓶或硬质玻璃瓶中,密封保留。
8.2.2.4氯化钾标准溶液:c(KCl)=0.001 mol/L。
用移液管正确吸收(8.2.2.3)氯化钾标准溶液100.00 mL,移人1000mL容量瓶中,用新制备一级试剂水(20士2)℃稀释至刻度,混匀。
8.2.2.5氯化钾标准溶液在不一样温度下电导率见下表2。
8.2.3 仪器
8.2.3.1电导率仪:测量范围:0µs/cm~104µs/cm
8.2.3.2电导电极(简称电极):铂黑电极。
8.2.3.3温度计:试验室测定时精度为士0.1℃ ,非试验室测定时精度为士0.5℃。
8.2.4 分析步骤
8.2.4.1 电导率仪校正、操作、读数应按其使用说明书要求进行。
8.2.4.2 依据水样电导率大小,选择不一样电导池常数电极。将选择好电极用二级试剂水洗净,再冲洗2~3次,浸泡备用。
8.2.4.3试验室测量时,取50mL至100mL水样,放人塑料杯或硬质玻璃杯中,将电极和温度计用被测水样冲洗2~3次后,浸人水样中进行电导率、温度测定,反复取样测定2~3次,在试验室测定时测定结果读数相对误差均在士1%以内,即为所测电导率值。同时统计水样温度。
8.2.4.4 非试验室测定时,取50mL至100mL水样,放人塑料杯或硬质玻璃杯中,将电极和温度计用被测水样冲洗2~3次后,浸人水样中进行电导率、温度测定,反复取样测定2~3次,测定结果读数相对误差均在士3%以内,即为所测电导率值。同时统计水样温度。
8.2.4.5 电导率仪若带有温度自动赔偿,应按仪器使用说明结合所测水样温度将温度赔偿调至对应数值.
8.2.4.6 电导池常数校正
用校正电导池常数电极测定已知电导率氯化钾标准溶液(其温度为25℃ 士0.1 ℃)电导率(见附表2)。按下式计算电极电导池常数。若试验室无条件进行校正电导池常数时,应送相关部门校正。
K = (S0 + S1)/S2
K-电极电导池常数,cm。
S0-配制氯化钾所用试剂水电导率μs/cm(25℃士0.1℃)。
S1-氯化钾标准溶液电导率μs/cm(25℃士0.1℃)。
8.2.5精密度
试验室测量时测定结果读数相对误差士1%。
非试验室测定时结果读数相对误差士3%。
附表2 氯化钾溶液电导率
浓
度
温
度
℃
1N
0.1N
0.01N
0.02N
1℃
0.06713
0.00736
0.000800
0.001566
2℃
0.06886
0.00757
0.000824
0.001612
3℃
0.07061
0.00779
0.000848
0.001659
4℃
0.07237
0.00800
0.000872
0.001705
5℃
0.07414
0.00822
0.000896
0.001752
6℃
0.07593
0.00844
0.000921
0.001800
7℃
0.07773
0.00866
0.000945
0.001848
8℃
0.07954
0.00888
0.000970
0.001896
9℃
0.08136
0.00911
0.000995
0.001954
10℃
0.08319
0.00933
0.001020
0.001994
11℃
0.08504
0.00956
0.001045
0.002043
12℃
0.08389
0.00979
0.001070
0.002093
13℃
0.08876
0.01002
0.001095
0.002142
14℃
0.09068
0.01025
0.001121
0.002193
15℃
0.09252
0.01048
0.001147
0.002243
16℃
0.09441
0.01072
0.001173
0.002294
17℃
0.09631
0.01095
0.001199
0.002345
18℃
0.09822
0.01119
0.001225
0.002397
19℃
0.10014
0.01143
0.001251
0.002449
20℃
0.10207
0.01167
0.001278
0.002501
21℃
0.10400
0.01191
0.001305
0.002553
22℃
0.10554
0.01215
0.001332
0.002606
23℃
0.10789
0.01239
0.001359
0.002659
24℃
0.10984
0.01264
0.001386
0.002712
25℃
0.11180
0.01288
0.001413
0.002765
26℃
0.11877
0.01313
0.001441
0.002819
27℃
0.11574
0.01337
0.001468
0.002873
28℃
0.01362
0.001496
0.002927
29℃
0.01387
0.001524
0.002981
30℃
0.01412
0.001552
0.003036
31℃
0.01437
0.001581
0.003091
32℃
0.01462
0.001609
0.003146
33℃
0.01488
0.001638
0.003201
34℃
0.01513
0.001667
0.003256
35℃
0.01539
0.003312
36℃
0.01564
0.003368
8.3 浊度测定(浊度仪法)
本方法采取无锡市光明浊度仪厂STZ-A24型浊度仪使用说明
8.3.1 原理
浊度是表现水中悬浮物对光线透过时所发生阻碍程度。水中含有泥土、粉尘、微细有机物、浮游动物和其它微生物等悬浮物和胶体物全部可使水中展现浊度。浊度仪采取90度散射光原理。由光源发出平行光束经过溶液时,一部分被吸收和散射,另一部分透过溶液。和入射光90°方向散射光强度符合雷莱公式:
Is=((KNV2)/λ4)×Io
其中:Io——入射光强度 Is——散射光强度 N——单位溶液微粒数
V——微粒体积 λ——入射光波长 K——系数
在入射光恒定条件下,在一定浊度范围内,散射光强度和溶液混浊度成正比。
上式可表示为:Is/I0= K′N (K′为常数)
依据这一公式,能够经过测量水样中微粒散射光强度来测量水样浊度。
8.3.2试剂
8.3.2.1 0NTU浊度标准样品
选择孔径为0.1um(或0.2um)微孔滤膜,过滤蒸馏水(或电渗析水、离子交换水),需要反复过滤两次以上,所获滤液即为检定用零浊度水,该水贮存于清洁、并用该水冲洗过玻璃瓶中备用。
8.3.2.2 10FTU和其它浊度标准样品
浊度检定中使用国家技术监督局颁布Formazine标准物质,GBW1中400(NTU,FTU)浊度(Formazine)标准物质,定值不确定度±3%,有效使用期限1年。不一样浊度值Formazine标准溶液,是用零浊度水和经检定合格容量器具,按百分比正确稀释Formazine浊度标准物质面取得。400度Formazine标准物质需存放在电冰箱冷藏室内(4~8℃)保留。已稀释至低浊度值标准溶液不稳定,不宜保留,应随用随配。
8.3.3 仪器
散射光浊度仪:STZ-A24型(无锡市光明浊度仪厂)
8.3.4分析步骤
8.3.4.1校准零位
8.3.4.1.1 开启电源预热3~5分钟
8.3.4.1.2 将样品杯用零度水清洗三遍后,注入约50ml零度水,用滤纸擦净样杯。
8.3.4.1.3 将样杯平稳置于样杯室内,选择一档,调整调零拨盘,使仪器显示“0.00”。
8.3.4.1.4 取出样杯,此时显示某一数值,这一数值就是“定标值”,记住该值在测量中可随时监视零位,以确保测量精度。
8.3.4.1.5 若“定标值”超出一档量程,可在二档读取定标值。
8.3.4.2 浊度测量
8.3.4.2.1 用零度水润洗样杯后,缓慢注入约50ml被测样品,用滤纸擦净样杯。
8.3.4.2.2 选择合适档位,在不超量程时尽可能选择低级位。
8.3.4.2.3 将样杯平稳地送入样杯室内,使测量指示灯量,关闭样杯室门。
8.3.4.2.4 待数字相对稳定后,读出显示数值即为被测溶液浊度值。
8.3.4.2.5 测量中注意监视“定标值”,以一直保持正确零位。
8.3.4.3 浊度校准
8.3.4.3.1 按8.3.4.1校准好零位。
8.3.4.3.2 将量程选择置二档(0~25NTU)。
8.3.4.3.3 往样杯中注入约50ml10FTU标准浊度液。
8.3.4.3.4 按8.3.4.2对10FTU标准液进行测量。
8.3.4.3.5 若测定值为10NTU,则无需调整。
8.3.4.3.6 若测定值偏离10NTU,用小起子缓慢旋动“校准”电位器,使测定值为10NTU。
8.3.5 注意事项
8.3.5.1 调零用零度水要纯。
8.3.5.2 使用标准10FTU标准浊度液。
8.3.5.3 操作要规范。
8.4 悬浮物测定(重量法)
本方法采取国家标准 GB 11901-89《水质悬浮物测定》
8.4.1 原理
取适量水样,经过滤后,所得残渣烘干至恒重,即为悬浮物含量。水样中悬浮物是指水样经过孔径为0.45μm滤膜,截留在滤膜上并于103~105℃烘干至恒重物质。
8.4.2 试剂
蒸馏水或相同纯度水。
8.4.3仪器
8.4.3.1 常见试验室仪器
8.4.3.2 全玻璃微孔滤膜过滤器。
8.4.3.3 GN-CA滤膜、孔径0.45μm、直径60mm。
8.4.3.4 吸滤瓶、真空泵
8.4.3.5 无齿扁咀镊子。
8.4.4 采样及样品贮存
8.4.4.1 采样
所用聚乙烯瓶或硬质玻璃瓶要用洗涤剂洗净。再依次用自来水和蒸馏水冲洗洁净。在采样之前,再用立即采集水样清洗三次。然后,采集含有代表性水样500~1000mL,盖严瓶塞。
注:漂浮或浸没不均匀固体物质不属于悬浮物质,应从水样中除去。
8.4.4.2 样品贮存
采集水样应立即分析测定。如需放置,应贮存在4℃冷藏箱中,但最长不得超出七天。
注:不能加入任何保护剂,以防破坏物质在固、液间分配平衡。
8.4.5 分析步骤
8.4.5.1 滤膜准备
用扁咀无齿镊子夹取微孔滤膜放于事先恒重称量瓶里,移入烘箱中于(103~105)℃烘干半小时后取出置干燥器内冷却至室温,称其重量。反复烘干、冷却、称量,直至两次称量重量差≤0.2mg。将恒重微孔滤膜正确放在滤膜过滤器滤膜托盘上,加盖配套漏斗,并用夹子固定好。以蒸馏水湿润滤膜,并不停吸滤。
8.4.5.2 测定
量取充足混合均匀试样100mL抽吸过滤。使水分全部经过滤膜。再以每次10mL蒸馏水连续洗涤三次,继续吸滤以除去痕量水分。停止吸滤后,仔细取出载有悬浮物滤膜放在原恒重称量瓶里,移入烘箱中于(103~105)℃下烘干一小时后移入干燥器中,使冷却到室温,称其重量。反复烘干、冷却、称量,直至两次称量重量差≤0.4mg为止。
注:滤膜上截留过多悬浮物可能夹带过多水份,除延长干燥时间外,还可能造成过滤困难,遇此情况,可酌情少取试样。滤膜上悬浮物过少,则会增大称量误差,影响测定精度,必需时,可增大试样体积。通常以5mg~100mg悬浮物量做为量取试样体积实用范围。
8.4.6 结果表示
悬浮物含量C(mg/L)按下式计算:
C=1000×1000×(A-B)/V
式中:C——水中悬浮物浓度,mg/L;
A——悬浮物+滤膜+称量瓶重量,g;
B——滤膜+称量瓶重量,g;
V——试样体积,mL。
8.5总硬度测定(EDTA络合滴定法)
本方法采取中石化《冷却水化学处理水质分析方法 总硬度测定》
8.5.1原理
在PH=10时,乙二胺四乙酸二钠(简称EDTA)和水中钙镁离子生成稳定络合物,指示剂铬黑T也能和钙镁离子所生成葡萄酒红色络合物,其稳定性不如EDTA和钙镁离子所生成络合物,当用EDTA滴定接终点时,EDTA自铬黑T葡萄酒红色络合物中夺取钙镁离子而使铬黑T指示剂游离,溶液由酒红色变为兰色,即为终点。其反应以下:
Mg2++HInd2-→MgInd-+H+
MgInd-+H2Y2-→MgY2-+H++HInd2-
Ca2++HIng2-→CaInd-+H+
CaInd-+H2Y2-→CaY2-+H++HInd2-
式中:HInd2-—铬黑T指示剂(蓝色)
Mglnd-— 镁和铬黑T络合物(酒红色);
Y2-—乙二胺四乙酸离子(无色)。
8.5.2.试剂
8.5.2.1 6mol/L 盐酸溶液
8.5.2.2 10%氨水:量取440ml氨水,稀释至1000ml。
8.5.2.3 1+1三乙醇胺溶液
8.5.2.4 铬黑T指示剂
称取0.5g铬黑T和4.5g盐酸羟胺,溶于100ml95%乙醇中,储于棕色瓶中。
8.5.2.5 PH=10氨—氯化铵缓冲溶液。
称取54g氯化铵,溶于200ml水中,加250ml氨水,用水稀释至1000ml。
8.5.2.6 0.01mol/LEDTA标准溶液
称取乙二胺四乙酸二钠(C10H14O8N2Na·2H2O)3.72g溶于1000ml水中,摇匀。
8.5.2.6.1标定
称取0.2g于800℃灼烧至恒重基准氧化锌(称准至0.0002g)。用少许水湿润,加2ml 6mol/L盐酸溶液至样品溶解,移入250ml容量瓶中,稀释至刻度。吸收此溶液20ml,移入250ml锥形瓶中,加入30ml水,然后用10%氨水中和至PH=7~8,(稍有氨味),加入5ml氨—氯化铵缓冲溶液,加2~4滴铬黑T指示剂,用EDTA溶液滴定至溶液由酒红色变为天蓝色。同时做空白试验。
8.5.2.6.2 计算
EDTA标准溶液摩尔浓度M(摩尔/升),按下式计算:
M = ×1000
式中:G——氧化锌重量,g;
V1——EDTA溶液用量,ml;
V0——空白试验EDTA溶液用量,ml;
81.39——氧化锌摩尔质量,g/mol。
8.5.3 仪器
8.5.3.1 滴定管:25ml酸式滴定管。
8.5.4分析步骤
8.5.4.1 吸收水样 50ml,移入250ml锥形瓶中,加入5ml氨—氯化铵缓冲溶液,2~4滴铬黑T指示剂,用0.01mol/L EDTA标准溶液滴定至溶液由酒红色变为纯蓝色即为终点。
8.5.5分析结果计算
水样中总硬度含量X(mg/L,以CaCO3计),按下式计算:
X = ×1000
式中:V——滴定时EDTA标准溶液消耗体积,ml;
M——EDTA标准溶液浓度,mol/L;
VW——水样体积,ml;
100.08——碳酸钙摩尔质量,g/mol。
8.5.6 注释
8.5.6.1若水样中有铁、铝干扰测定时,加1+1三乙醇胺1~3ml加以掩蔽。
8.5.6.2 若水样中有少许锌离子时,取样后可加β—氨基乙硫醇0.5ml加以掩蔽,若锌含量高,可另测锌含量,以后从总硬度中减去。
8.5.6.3 若测定中有返色现象,可将水样中经中速滤纸干过滤,去除悬浮碳酸钙。
8.5.7许可差
水中总硬度在300mg/L(以CaC03计)时,平行测定两结果差小于3.5mg/L。
8.5.8结果表示
取平行测定两结果算术平均值,作为水样总硬度含量。
8.6 钙离子测定(EDTA络合滴定法)
A法 本方法参考采取中石化《冷却水化学处理水质分析方法 钙离子测定》
8.6.1 原理
钙黄绿素能和水中钙离子生成莹光黄绿色络合物,在PH>12时,用EDTA标准溶液滴定钙,当靠近终点时,EDTA夺取和指示剂结合钙,溶液莹光黄绿色消失,呈混合指示剂红色,即为终点。
8.6.2试剂
8.6.2.1 1+1盐酸溶液
8.6.2.2 20%氢氧化钾溶液
8.6.2.3 钙黄绿素酚酞混合指示剂
称取钙黄绿素0.2g和酚酞0.07g置于研钵中,再加入20g氯化钾,研细混匀,贮于广口瓶中。
8.6.2.4 0.01mol/lEDTA标准溶液。(同总硬度测定)
8.6.3 仪器
8.6.3.1 滴定管:25ml。
8.6.3.2 移液管:5ml。
8.6.4 分析步骤
吸收经中速滤纸干过滤水样50ml,移入250ml锥形瓶中,加1+1盐酸3滴,混匀,加热煮沸半分钟,冷却至50℃以下加5ml 20%氢氧化钾溶液,再加约80mg钙黄绿素酚酞混合指示剂。用0.01mol/L EDTA标准溶液滴定至莹光黄绿色消失,出现红色即为终点。
8.6.5 计算
水样中钙离子含量X(毫克/升,以CaCO3计)。按下式计算:
X = ×1000
式中:V——滴定消耗EDTA标准溶液体积,毫升;
M——EDTA标准溶液浓度,摩尔/升;
VW——水样体积,毫升;
100.08——碳酸钙摩尔质量,克/摩尔。
8.6.6 注释
8.6.6.1 若测定时有轻度返色,可滴至不返色为止。
8.6.6.2 若返色严重可用慢速滤纸对水样进行“干过滤”。
8.6.6.3 也可采取钙指示剂或紫脲酸胺作指示剂。
8.6.7 许可差
水样中钙离子含量在500mg/L(以CaCO3计)时,平行测定两结果差小于2mg/L。
8.6.8 结果表示
取平行测定两结果算术平均值,作为水样钙离子含量。
B法 本方法采取国家标准GB/T 15452—95《工业循环冷却水钙、镁离子测定》
8.6.1 原理
钙离子测定是在PH为12-13时,以钙-羧酸为指示剂,用EDTA标准滴定溶液测定水样中钙离子含量。滴定时EDTA和溶液中游离钙离子仅应形成络和物,溶液颜色改变由紫色变为亮蓝色时即为终点。
镁离子测定是在PH为10时,以铬黑T为指示剂,用EDTA标准滴定溶液测定水样中钙、镁离子含量。溶液颜色改变由紫红色变为纯蓝色时即为终点,由钙镁合量中减去钙离子含量即为镁离子含量。
8.6.2试剂
8.6.2.1硫酸(GB 625):1+1溶液。
8.6.2.2 过硫酸钾(GB 641):40g/L溶液。
8.6.2.3 三乙醇胺:1+2水溶液。
8.6.2.4 氢氧化钾(GB 629):200g/L溶液。
8.6.2.5 钙-羧酸指示剂:0.2g钙-羧酸指示剂[2-羟基-1-(2-羟基-4-磺基-1-萘偶氮)-3-萘甲酸]和100g氯化钾(GB 646)混合研磨均匀,储存于磨口瓶中。
8.6.3 仪器
8.6.3.1 滴定管:25ml。
8.6.3.2 移液管:50ml。
8.6.4 分析步骤
8.6.4.1 钙离子测定
用移液管吸收50ml水样于250ml锥型瓶中,加1ml硫酸溶液和5ml过硫酸钾溶液加热煮沸至近干 ,取下冷却至室温加50ml水,3ml三乙醇胺、7ml氢氧化钾溶液和约0.2g钙-羧酸指示剂,用EDTA标准滴定溶液滴定,近终点时速度要缓慢,当溶液颜色由紫红色变为亮蓝色时即为终点。
8.6.4.2 镁离子测定
用移液管吸收50ml水样于250ml锥型瓶中,加1ml硫酸溶液和5ml过硫酸钾溶液加热煮沸至近干 ,取下冷却至室温加50ml水,3ml三乙醇胺、用氢氧化钾溶液调整PH值近中性,再加5ml氨-氯化铵缓冲溶液和三滴铬黑T指示剂,用EDTA标准滴定溶液滴定,近终点时速度要缓慢,当溶液颜色由紫红色变为纯蓝色时即为终点。
注:①原水中钙、镁离子含量测定不用加硫酸及过硫酸钾加热煮沸。
②三乙醇胺用于消除铁、铝离子对测定干扰,原水中钙、镁离子测定不加入。
③过硫酸钾用于氧化有机磷系药剂以消除对测定干扰。
8.6.5 计算
8.6.5.1水样中钙离子含量X(毫克/升,以CaCO3计)。按下式计算:
X = ×106
式中:V1——滴定钙离子消耗EDTA标准溶液体积,毫升;
——EDTA标准滴定溶液浓度,摩尔/升;
V——水样体积,毫升;
0.04008——和1.00mlEDTA标准滴定溶液[(EDTA)=1.000mol/L]相当,以克表示钙质量。
8.6.5.2水样中镁离子含量X(毫克/升,以CaCO3计)。按下式计算:
X = ×106
式中V2——滴定钙镁合量时,消耗EDTA标准溶液体积,毫升;
V1——滴定钙离子消耗EDTA标准溶液体积,毫升;
——EDTA标准滴定溶液浓度,摩尔/升;
V——水样体积,毫升;
0.02431——和1.00mlEDTA标准滴定溶液[(EDTA)=1.000mol/L]相当,以克表示镁质量。
8.6.7 许可差
取平行测定两结果算术平均值为测定结果,平行测定结果许可差小于0.4mg/L。