第一章 網路傳真服務系統軟硬體需求
1.1 DTV-99 Plus Super 7 Book-Size PC Specifications
Model number
DTV-99 Plus Super Socket 7
CPU:
Support Super Socket 7 P-54/P-55/K6-2/3-AFR/M3 CPU,66/75/83/95/100MHz bus frequency
Main Memory:
Notebook DIMM*1 PCs up to 128MB.(SDRAM or EDO)
BIOS:
I-O Pre-set IRQ/ PnP / APM / DMI / ESCD / PCI bus 2.1 / DRAM ECC
Quick Boot/ HW Monitor(LDCM).
Cache Memory:
512KB P.B.SRAM.
Expansion Slots:
3 FREE Slots Riser Card: One ISA Bus, One PCI Bus and One ISA/PCI sharing Bus
with COM3/COM4|(Option) FDD output and IDE2 CD-ROM output Connector. IRQ selector by BIOS setup (Jumper_less) and +5v or +12v output on pin 9th by jumper selector.
Serial Port:
COM1, COM2, COM3, COM4 (COM3/4 output on Riser card.)
Parallel Port:
One LPT port(SPP/EPP/ ECP).
USB:
TWO USB port support Windows 95/98.
FDD:
1.44MB/ 3.5" FDD x 1.
Enhance PCI IDE:
On board PCI Bus Master IDE1/2 controller with Win95 utility, support Ultra DMA/33.
AGP 3D Graphics Port:
-SiS530AGP, Share memory from 2MB up to 8MB
-Support AGP( 2X) VGA controller.
-Support 3D/2D Graphics Accelerator.
-Support Video Accelerator.
-Support VESA DPMS VGA Monitor for Power Management.
-Direct X, VPE, MPEG2.
-NT4.0/5.0, Windows95/98 utility.
-APM/ACPI 1.0.
PCI LAN Port:
(10/100 Mbs Auto)
-ACPI/NT4.0/5.0 (NDIS 5).
-NT4.0/Win95/98 Utility.
-Remote Boot ROM for NT4.0.
-Wake-on-Lan (WOL)
Disk On Chip Socket
2MB up to 144MB.
PS/2 Keyboard Port:
PS/2 type.
PS/2 Mouse Port:
PS/2 type.
Front Panel:
-AC power on/off button.
-3 LED indicators: Power On/Off, Suspend mode state & LAN state.
-1.44MB FDD
-Door with Lock for FDD and Power switch.
Back Panel:
-VGA CRT 15-pin DSUB connector.
-COM 1/2 9-pin DSUB output connector.
-LPT 25-pin DSUB connector,
-COM 3/4 9-pin DSUB output connector.(Option)
-PS/2 Keyboard & Mouse connector.
-LAN RJ-45 output connector.
-USB1/USB2 connector.
AC Power Supply:
80W Internal Power Supply (UL, CSA, VDE, EMI meets FCC *B*).
AC Power Source:
AC 90V to 264V, 60HZ/50HZ AT Type.
Vertical Stand:
Two U type stand per set.
Case Dimension:
11"(W)x11"(D)x3"(H) (280x280x75mm).
Export Packing:
Each set packing: 34x34x17cm. NW/GW: 5.5kgs/6.5kgs
S/W Compatibility:
DOS/OS2 V2.1/SCO XENIX: V2.3.2/SCO UNIX V3.2/NOVELL/ WIN 3.1/ 95/98/NT4.0.
Operation Temperature:
0 o C to 45 o C(without HDD up to 60 o C)
Storage Temperature:
-25 o C to 85 o C
OPTIONS:
PCI Audio Card:
Game port:
-Audio Line in/out Mic-in/Game port,.
-PCI 2.1/ACPI 1.0/WDM.
-PC98 Logo, NT4.0/Win95/98 utility.
Serial Port B:
COM3,COM4 On riser Card.
PCI Modem Card
Win95/98 Utility (33.6 or 57K)support PCI2.1/ACPI1.0.
IDE2 CD-ROM
On board PCI Bus Master IDE1/2 controller with Win95 utility, support Ultra DMA/33.
Disk On Chip
2MB up to 144MB.
Disk On Module Port
Compact Flash Card ATA IDE Type I PC card socket.
The Front Panel Composition
Rear Panel Composition
1.2 作業系統相關資訊
系統軟體
內容版本
Operating System:
Red Hat Linux
Distribution Version:
Red Hat Linux release 6.1 (Cartman) + CLE v0.9 (Yami)
Operating System Version:
#1 Sun Jan 23 02:41:32 CST 2000
Operating System Release:
2.2.14-3.0
Fax Server
mgetty+sendfax 1.1.21-2-2
Web Server
Apache Version: Apache/1.3.12
Apache Release: 10312100
Apache API Version: 19990320
FTP Server
wu-2.6.0-1
Mail Server
sendmail 8.9.3-15
DNS Server
nameserver-6.0-2
PHP
PHP Version 3.0.15
MySQL
MySQL 3.22.32-1CLE
Postgresql
postgresql 6.5.3-3CLE
Perl
Perl release 5.005_03
芃寶資訊傳真管理系統
version 1.0.1
第二章 網路傳真服務系統設定
2.1 更改主機系統管理者帳號之密碼(請直接在主機操作)
2.1.1 請輸入系統管理者帳號:root與密碼(新機器的密碼預設為neotech)
2.1.2 執行passwd
2.1.3 輸入兩次新密碼
Red Hat Linux release 6.1 (Cartman) + CLE v0.9 (Yami)
Kernel 2.2.14-3.0 on an i586
login: root
Password: xxxxxxx
[ccy@fax ccy]$ passwd
New UNIX password: xxxxxx
Retype new UNIX password: xxxxxx
passwd: all authentication tokens updated successfully
[ccy@fax ccy]$
2.2 新增使用者
2.2.1請輸入系統管理者帳號:root與密碼。或透過網路以NetTerm等telnet的連線軟體以一般的使用者身份登入主機,再su成root的身份。
2.2.2 執行linuxconf
2.2.3 將亮棒移至[user accounts],按Enter
2.2.4 按Tab鍵將功能選項跳到[Add]
2.2.5 輸入帳號,使用者姓名,使用者個人目錄
帳號
使用者姓名
使用者個人目錄
2.2.6 輸入密碼,按Accept鍵
建檔完成!2.3 修改、刪除使用者
2.3.1 選擇要修改刪除之帳號,按Enter鍵
2.2.4 請直接修改資料後按[Accept],或按[Del]刪除
2.4 設定TCP/IP
2.4.1將亮棒移至[Name Server Specification],按Enter
2.4.2 選擇Name ServerSpecification按 [Enter]
2.4.3 請將140.115.1.31刪除,若貴公司有dns,請依貴公司之設定,按 [Tab]鍵跳到 Accept的按鈕,按 [Enter]
2.4.4 選擇Routing and geteways按 [Enter]
2.4.5選擇Set Defaults按 [Enter]
2.4.6 請將 140.115.1.254刪除,若貴公司有getway,請依貴公司之設定,再按 [Tab]鍵跳到 Accept的按鈕,按 [Enter]
2.4.7. 再,按 [Tab]鍵跳到 Quit的按鈕,按 [Enter]結束
2.4.8 請依貴公司所配置的設定IP address與Netmask。
2.5 設定mgetty+sendfax
2.5.1在主機以 root 登入到系統 (密碼:neotech),執行pe2 .
2.5.2 選擇 .. 按 [Enter] 跳回上一層
2.5.3選擇 etc 按 [Enter] 跳至 /etc 目錄下
2.5.4選擇 mgetty+sendfax 按 [Enter] 跳至 /etc/mgetty+sendfax 目錄下
2.5.5選擇 sendfax.config 按 [Enter] 編輯 /etc/mgetty+sendfax/sendfax.config
#請修改下列資訊
# sendfax configuration file
# this is a sample configuration file, see mgetty.info for details
# comment lines start with a "#", empty lines are ignored
# ----- global section -----
# In this section, you put the global defaults, per-port stuff is below
# tell everybody what's going on
verbose y
# ... and send everything to the log file (quite detailed)
debug 5
# which devices to use for outgoing faxes
#設定可由ttyS0,ttyS1,ttyS2,ttyS3發送傳真(4個 COM Port)(請依實際狀況設定)
fax-devices ttyS0:ttyS1:ttyS2:ttyS3
# which fax number to transmit to the receiving station設定貴公司之傳真號碼
fax-id 886 2 23645313 NEOTECH
# which command is used to dial out? (Could be ATD, ATDP, ATX3D0W...)
# 若需透過總機撥號時需設定,否則請在下一行第一個字元插入#
#dial-prefix ATX3DT
# try transmitting every page three times, continue if 3rd try fails as well
max-tries 3
max-tries-continue y
# ----- port specific section -----
#
# Here you can put things that are valid only for one line, not the others
#
# Modem on ttyS0 needs special initialization to do h/w handshaking
#port ttyS0
# modem-handshake AT&K4
# Modem on ttyS1 doesn't work reliably in class 2.0, use class 2 instead
#port ttyS1
# modem-type cls2
2.5.6 按 [F3] 儲存離開
2.5.7選擇 mgetty.config 按 [Enter] 編輯 /etc/mgetty+sendfax/mgetty.config
# mgetty configuration file
#
# this is a sample configuration file, see mgetty.info for details
#
# comment lines start with a "#", empty lines are ignored
# ----- global section -----
#
# In this section, you put the global defaults, per-port stuff is below
# set the global debug level to "4" (default from policy.h)
debug 4
# set the local fax station id 設定貴公司之傳真號碼
fax-id 886 2 23645313 NEOTECH
# access the modem(s) with 38400 bps
speed 38400
# use these options to make the /dev/tty-device owned by "uucp.uucp"
# and mode "rw-rw-r--" (0664). *LEADING ZERO NEEDED!*
#port-owner uucp
#port-group uucp
#port-mode 0664
# use these options to make incoming faxes owned by "root.uucp"
# and mode "rw-r-----" (0640). *LEADING ZERO NEEDED!*
fax-owner nobody
fax-group nobody
fax-mode 0640
# ----- port specific section -----
#
# Here you can put things that are valid only for one line, not the others
#
# Zoom V.FX 28.8, connected to ttyS0: don't do fax, less logging
#
#port ttyS0
# debug 3
# data-only y
# some other Rockwell modem, needs "switchbd 19200" to receive faxes
# properly (otherwise it will fail with "timeout").
#
#port ttyS1
# speed 38400
# switchbd 19200
# ZyXEL 2864, connected to ttyS2: maximum debugging, grab statistics
#
#port ttyS2
# debug 8
# init-chat "" \d\d\d+++\d\d\dAT&FS2=255 OK ATN3S0=0S13.2=1 OK
# statistics-chat "" AT OK ATI2 OK
# statistics-file /tmp/statistics.2864
# modem-type cls2
# direct connection of a VT100 terminal which doesn't like DTR drops
#
#port ttyS3
# direct y
# speed 19200
# toggle-dtr n
2.5.8 按 [F3] 儲存離開
2.5.9再按 [F4]離開,重新開機
第三章 網路傳真服務系統操作
一、 登入傳真服務系統
(一) 先確定用戶端的電腦是否正確連接區域網路(Local LAN)或網際網路(Internet)。
(二) 開啟瀏覽器(Browser,例如Microsoft Internet Explorer 5),登入傳真服務系統的網站,例如: http://140.115.11.177 。輸入系統管理員給您的帳號與密碼。本系統第一次使用的系統管理帳號為neotech,密碼為neotech,請系統管理員在啟用本系統後,立即更改該管理帳號的密碼。
圖3-1
(三) 完成登入程序
二、 系統主功能
本系統共分類成接收傳真文件、傳送傳真文件、系統管理三大主功能(系統界面如圖3-2所示)。
圖3-2
芃寶科技首頁
系統管理
傳送傳真
接收傳真
(一) 接收傳真文件:
當您點選 接收傳真文件 的超連結後,則進入接收傳真的顯示畫面,如圖3-3所示。本界面依您的權限提供所有您能查閱的接收傳真,每一頁的顯示筆數可在系統管理功能內設定,而記錄則依日期的先後順序降冪排序。換言之,最新的一筆傳真記錄會置於第一頁第一筆的位置,您可透過[首頁][上一頁][下一頁][末頁]來更換顯示的傳真記錄。每一筆記錄的會有六種接收狀態,分別說明如下:
本傳真接收成功
本傳真接收失敗
顯示本傳真之文件影像
本傳真已由專人指派給擁有者
本傳真尚未由專人指派給某擁有者
顯示本傳真之詳細資訊
圖3-3
1. 當您要查看某一筆傳真的時候,請用滑鼠點選,系統會將該傳真影像以新視窗依傳真頁數依序排列顯示(圖3-4)
圖3-4
2. 當您要查看某一筆傳真的詳細資訊,請用滑鼠點選,系統會將該傳真影像的詳細資訊顯示出來(圖3-5)
圖3-5
3. 當您的身份為系統管理者或傳真指派者時,您有權處理傳真指派的功能。請用滑鼠點選或,系統會將該傳真影像與詳細資訊顯示出來,其中有傳真文件擁有者與傳真文件擁有部門兩項選單供您指派(圖3-6)。您可選擇兩者或是其一指派。
圖3-6
(二) 傳送傳真文件:
當您點選 傳遞傳真文件 的超連結後,則進入傳送傳真的顯示畫面,如圖3-7所示。本界面提供查閱您自己所有的傳送傳真、發送傳真、客戶資料管理等三項子功能,記錄依日期的先後順序降冪排序。最新的一筆傳真記錄會置於第一頁第一筆的位置,您可透過[首頁][上一頁][下一頁][末頁]來更換顯示的傳真記錄。
圖3-7
1. 客戶資料管理:當您要管理自己的客戶資料時,請用滑鼠點選,系統會將會進入客戶管理界面(圖3-8)
圖3-8
(1) 當您要新增一筆客戶資料時,請用滑鼠點選[新增客戶],系統會顯示新增客戶編輯畫面(圖3-9)
圖3-9
輸入資料時,職業特性分類、客戶名稱、傳真號碼、允許傳送失敗次數一定要輸入,其中傳真號碼的的標準格式為(99)999-99999 ,也可省略為(99)99999999或99999999,但若外縣市的電話未輸入區域號碼,則本系統無法為您處理傳真的服務。
圖3-10
(2) 您也可以事先依規定的資料格式以純文字檔編輯好,再以檔案上傳方式整批匯入。
A. 請點選[整批新增客戶]
B. 請事先依範例格式建好客戶檔,點選[Browse…]選擇該檔
C. 選擇您的客戶檔後,按[Open]
D. 按[確定執行傳真作業]
E. 顯示上傳新增客戶成功與否之訊息
F. 完成建檔
2. 傳真作業
請點選[發送傳真],輸入下列相關資訊
(1) 傳真對象:您可用三種方式來選擇您傳真的發送對象
A. 從客戶名稱中挑選您傳真的對象(可加按Ctrl鍵複選客戶)
B. 以職業/特性來挑選您傳真的對象(可加按Ctrl鍵複選群組)
C. 手動輸入傳真號碼
D. 允許傳送失敗次數
(2) 傳真文件主旨
(3) 傳送文件:您可用二種方式來選擇您傳真的文件
A. 直接輸入文字傳真
B. 以PostScript格式檔(.ps)傳真
傳真作業範例一(直接輸入文字傳真)
(1) 輸入相關的傳真資訊
(2)從系統得知共有五筆傳真傳真等待發送
(3)傳真內容
傳真作業範例一(以PostScript格式檔(.ps)傳真)
(1) 請確定自己的電腦有新增一台[Apple LaserWriter]印表機
(2) 請在任何的應用軟體編輯您的傳真文件,執行列印功能,並選擇[Apple LaserWriter]印表機,並將[Print to file]打勾
(3) 請為此印表檔命名,並選擇某一個目錄存放此PS檔
(4) 輸入相關的傳真資訊,在傳真文件欄位選擇該PS檔,按[確定執行傳真作業]
(5) 從系統得知共有一筆傳真傳真等待發送
(6) 傳真內容
(三) 系統管理:當您點選 系統管理 的超連結後,則進入系統管理的顯示畫面。本界面提供新增、修改、查閱、刪除使用者、刪除接收傳真記錄、刪除傳送傳真記錄、刪除接收失敗記錄等數項子功能,記錄依使用者帳號排序。您可透過[首頁][上一頁][下一頁][末頁]來更換顯示的使用者記錄。
1. 若您的身份為系統管理者,則您的管理畫面如下圖所示
A. 新增傳真用戶:請點選[新增傳真用戶],輸入相關資訊後按[確定新增]
B. 要編修刪除某位傳真使用者,直接點選用戶帳號為您想要編修刪除的帳號
C. 若要編修,直接修資料後按[確定修改],若要刪除,直接按[確定刪除]即可。
2. 若您的身份為系統管理者,則您的管理畫面如下圖所示,您只可修改個人的資料。
3. 刪除接收傳真記錄:輸入起始日期到終止日期按[確定刪除]
4. 刪除傳送傳真記錄:輸入起始日期到終止日期按[確定刪除]
5. 刪除接收失敗傳真記錄:按[刪除接收失敗記錄]即可。
第四章 網路傳真服務系統操作(公司內部技術文件)
4.1 Linux安裝程序
4.1.1 插入RedHat 6.1+CLE9.0系統光碟,用自訂方式安裝,以default選項安裝完整個系統(Web Server先不要安裝)
4.1.2 進入X-windows