收藏 分销(赏)

光腔衰荡光谱(CRDS)技术.doc

上传人:s4****5z 文档编号:8884857 上传时间:2025-03-06 格式:DOC 页数:21 大小:334.50KB 下载积分:10 金币
下载 相关 举报
光腔衰荡光谱(CRDS)技术.doc_第1页
第1页 / 共21页
光腔衰荡光谱(CRDS)技术.doc_第2页
第2页 / 共21页


点击查看更多>>
资源描述
中国地质大学(武汉) 材化学院 课程名称:文件检索 班级:031111 姓名:刘欢 学号:20111000544 题目(4):光腔衰荡光谱(CRDS)技术 1.Comparison of water isotope-ratio determinations using two cavity ring-down instruments and classical mass spectrometry in continuous ice-core analysis 作者:Olivia J. Maselli ,  Diedrich Fritzsche ,  Lawrence Layman ,  Joseph R. McConnell ,  Hanno Meyer 作者单位:Desert Research Institute;;Alfred-Wegener Institute for Polar and Marine Research 刊名:Isotopes in Environmental and Health Studies, 2013, Vol.49 (3), pp.387-398 来源数据库:Taylor & Francis期刊 DOI:10.1080/10256016.2013.781598 关键词:cavity ring-down  ; hydrogen-2  ; ice-core  ; isotope measurements  ; methods and equipment  ; oxygen-18  ; paleoclimatology  ; water  ; 原始语种摘要:We present a detailed comparison between subsequent versions of commercially available wavelength-scanned cavity ring-down water isotope analysers (L2120-i and L2130-i, Picarro Inc.). The analysers are used in parallel in a continuous mode by adaption of a low-volume flash evaporation module. Application of the analysers to ice-core analysis is assessed by comparison between continuous water isotope measurements of a glacial ice-core from Severnaya Zemlya with discrete isotope-ratio mass spectrometry measurements performed on parallel samples from the same ice-core. The great advances between instrument versions, particularly in the measurement of δ2H, allow the continuous technique to achieve the same high level of accuracy and precision obtained using traditional isotope spectrometry techniques in a fraction of the experiment time. However, when applied to continuous ice-core measurements, increased integration times result in a compromise of the achievable depth resolution of the ice-core records. 相似文献: [1] Olga Garmash. Deposition History of Polychlorinated Biphenyls to the Lomonosovfonna Glacier, Svalbard: A 209 Congener Analysis. [J].Environ. Sci. Technol.,2013 [2] Ulrich Schimschal. Mathematical model of gamma-ray spectrometry borehole logging for quantitative analysis (Open-file report / United.... [M].,1981 2.Toward a real-time measurement of atmospheric mercury concentrations using cavity ring-down spectroscopy 作者:X. Faïn ,  H. Moosmüller ,  D. Obrist 刊名:Atmospheric Chemistry and Physics Discussions, 2009, Vol.9 (5), pp.22143 来源数据库:DOAJ期刊 原始语种摘要:A new sensor based on cavity ring-down spectroscopy (CRDS) has been developed for the measurement of gaseous elemental mercury (Hg0) mass concentration with sub-ng m−3 detection limit and high temporal resolution. Cavity ring-down spectroscopy is a direct absorption technique that utilizes path lengths of up to multiple kilometers in a compact absorption cell and has a significantly higher sensitivity than conventional absorption spectroscopy. Our prototype uses a frequency-doubled, tuneable dye laser emitting pulses at ~253.65 nm with a pulse repetition frequency of 50 Hz. The dye laser incorporates a unique piezo element attached to its tuning grating allowing it to tune the laser on and off the Hg0 absorption line on a pulse to pulse basis to facilitate... differential absorption measurements. Hg0 absorption measurements with this CRDS laboratory prototype are highly linearly related to Hg0 concentrations determined by a Tekran 2537B analyzer over a Hg0 concentration range of four orders of magnitude, from 0.2 ng m−3 to 573 ng m−3 implying excellent linearity of both instruments. The current CRDS instrument has a~sensitivity of 0.10 ng m−3 at 10 s time resolution. This tool opens new prospects for the study of Hg0 because of its high temporal resolution and reduced limited sample volume requirements (<0.5 l of sample air). Future applications may include ambient Hg0 flux measurements with eddy covariance techniques, which require measurements of Hg0 concentrations with sub-ng m−3 sensitivity and sub-second time resolution. 相似文献: [1] Paul J B. Ultrasensitive absorption spectroscopy with a high-finesse optical cavity and off-axis alignment.. [J].Applied Optics,2008,40(27) [2] Zingg W. Insulin absorption from the peritoneal cavity.. [J].Life support systems : the journal of the European Society for Artificial Organs,1985,3(4) [3] Synovets A S. [Effect of proteolytic enzymes and their inhibitors on absorption from the abdominal cavity].. [J].Fiziologicheski? zhurnal,1980,26(5) [4] Gherman Titus. Modelocked cavity--enhanced absorption spectroscopy.. [J].Optics Express,2002,10(19) [5] Morville Jérĵme. Effects of laser phase noise on the injection of a high-finesse cavity.. [J].Applied Optics,2002,41(33) [6] Williams Skip. Quantitative detection of singlet O2 by cavity-enhanced absorption.. [J].Optics Letters,2004,29(10) [7] Spuler Scott. Numerical analysis of beam propagation in pulsed cavity ring-down spectroscopy.. [J].Applied Optics,2002,41(15) [8] Zhao Hui. [Off-axis cavity enhanced absorption spectroscopy detection techniques for the measurement of carbon dioxide].. [J].Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis,2012,32(1) [9] Garro Barrio J. [Causes of fractures in amalgam cavity restorations and their prevention].. [J].Revista de actualidad estomatológica espa?ola / Ilustre Consejo General de Colegios de Odontólogos y Estomatólogos de Espa?a,1984,44(335) [10] Douvitsas G P. [New aspects in cavity preparation for amalgam restorations].. [J].Stomatologia,1983,40(4) [11] Thomas A E. Evaluation of principles of cavity preparation design.. [J].The Alabama journal of medical sciences,1983,20(4) [12] Eames W B. The effects of trichloroacetic acid on the hard and soft tissues of the oral cavity.. [J].Journal of the Georgia Dental Association,1973,47(2) [13] Wang T. Experimental observation of photon echoes and power-efficiency analysis in a cavity environment.. [J].Optics letters,2007,23(22) [14] Zippilli Stefano. Suppression of Bragg scattering by collective interference of spatially ordered atoms with a high-Q cavity mode.. [J].Physical Review Letters,2004,93(12) [15] Geremia J M. Inverse-problem approach to designing photonic crystals for cavity QED experiments.. [J].Physical Review E (Statistical, Nonlinear, and Soft Matter Physics),2003,66(6 Pt 2) [16] Arrowsmith P. Short-cavity hydrogen-halide laser.. [J].Applied Optics,1983,22(17) [17] Tan H H. [Opinion of patients on cavity preparation by extended duty dental hygienists].. [J].Nederlands Tijdschrift voor Tandheelkunde,1981,88(2) [18] Shimamura Tatsuro. Crystal structure of the native chaperonin complex from Thermus thermophilus revealed unexpected asymmetry at the cis-cavity.. [J].Structure,2004,12(8) [19] Jewett A I. Accelerated folding in the weak hydrophobic environment of a chaperonin cavity: creation of an alternate fast folding pathway.. [J].PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA,2004,101(36) [20] Ewbank M D. Frequency shift and cavity length in photorefractive resonators.. [J].Optics Letters,1985,10(10) 3.Real-time monitoring of breath ammonia during haemodialysis: use of ion mobility spectrometry (IMS) and cavity ring-down spectroscopy (CRDS) techniques. 作者:Neri Giovanni ,  Lacquaniti Antonio ,  Rizzo Giuseppe ,  Donato Nicola ,  Latino Mariangela ,  Buemi Michele 作者单位:Correspondence and offprint requests to: Michele Buemi; E-mail: buemim@unime.it. 刊名:Nephrology, Dialysis, Transplantation, 2012, Vol.27 (7), pp.2945-52 来源数据库:PubMed期刊 DOI:10.1093/ndt/gfr738 原始语种摘要:Background The diffusion of high-performance analytical technology has opened prospects for breath diagnosis as a non-invasive diagnostic tool. In this study, ion mobility spectrometry (IMS) and cavity ring-down spectroscopy (CRDS) techniques were used to analyse ammonia gas NH3 in real-time in breath from patients undergoing haemodialysis (HD) treatment and any correlation with blood urea nitrogen (BUN) levels and Kt/V were investigated. Methods We studied 20 patients on intermittent HD treatment. The first breath samples were taken before the start of dialysis and further breath samples were taken every hour during the treatment and after the end of the session. An evaluation was also made of 20 healthy volunteers, acting as controls [healthy subjects (HS)]. Results Breath ammonia... concentrations were higher in CRDS-HD (914.5 ± 301.4 versus 280 ± 120 parts per billion (p.p.b.), P < 0.0001) and IMS-HD patients (964.4 ± 402.4 versus 280 ± 120 p.p.b., P < 0.0001) than in HS. We assessed real-time variations in the levels of NH3 and showed a continuous decrease in the levels of NH3. Expired NH3 correlated directly with BUN levels, both in the IMS-HD (P = 0.002; r = 0.84; P = 0.009; r = 0.76) and in the CRDS-HD group (P = 0.005; r = 0.80; P = 0.008; r = 0.77), respectively, both before and at the end of dialysis. A direct correlation with Kt/V was found in both groups studied (IMS-HD: P = 0.003; r = 0.82; CRDS-HD: P = 0.006; r = 0.79). Conclusions Breath monitoring of NH3 with IMS and CRDS techniques could be useful to assess the real-time clinical status of patients during HD. By using pre-dialysis ammonia values, an approximate calculation of the Kt/V(urea) ratio can be established. 相似文献: [1] Neri Giovanni. Real-time monitoring of breath ammonia during haemodialysis: use of ion mobility spectrometry (IMS) and cavity ring-down spectroscopy (CRDS) techniques.. [J].Nephrology, Dialysis, Transplantation,2012,27(7) [2] Léonard Céline. The vibrational levels of ammonia.. [J].Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy,2002,58(4) [3] Thompson M. The bilayer lipid membrane as a basis for a selective sensor for ammonia.. [J].Talanta,1983,30(12) [4] Kretschmer Robert. Mechanistic aspects and elementary steps of N-H bond activation of ammonia and C-N coupling induced by gas-phase ions: a combined experimental/computational exercise.. [J].Chemistry: A European Journal,2011,18(1) [5] Vinogradoff V. Acetaldehyde solid state reactivity at low temperature: formation of the acetaldehyde ammonia trimer.. [J].The Journal of Physical Chemistry Part A: Molecules, Spectroscopy, Kinetics, Environment and General Theory,2012,116(9) [6] Jetzki Martin. Vibrational delocalization in ammonia aerosol particles.. [J].The Journal of Chemical Physics,2004,120(24) [7] Thompson Helen. Structural studies of ammonia and metallic lithium-ammonia solutions.. [J].American Chemical Society. Journal,2003,125(9) [8] Amaro Rommie. Developing an energy landscape for the novel function of a (beta/alpha)8 barrel: ammonia conduction through HisF.. [J].PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA,2003,100(13) [9] Bozoki Zoltan. Near-infrared diode laser based spectroscopic detection of ammonia: a comparative study of photoacoustic and direct optical absorption methods.. [J].Applied Spectroscopy,2002,56(6) [10] Rudling J. Development and evaluation of field methods for ammonia in air.. [J].Scandinavian Journal of Work, Environment & Health,1984,10(3) [11] Rodger M R. Enzymic fluorometric assay of plasma ammonia with a centrifugal analyzer.. [J].Clinical Chemistry (Washington, DC),1984,30(10) [12] Svensson G. Rapid determination of ammonia in whole blood and plasma using flow injection analysis.. [J].Clinica Chimica Acta,1982,119(1-2) [13] Danielson N D. Fluorometric determination of hydrazine and ammonia separately or in mixtures.. [J].Talanta,1982,29(5) [14] Nikolelis D P. Potentiometric determination of certain alpha-aminohydroxy compounds by using an ammonia gas-sensing electrode.. [J].Talanta,1982,29(11 Pt 1) [15] Pisarenko O I. [Emission spectroscopic determination of the 15N in the ammonia and amino acids isolated from biological material].. [J].Voprosy medit?sinsko? khimii,1981,27(5) [16] Poppe László. Preparation of unnatural amino acids with ammonia-lyases and 2,3-aminomutases.. [J].Methods in Molecular Biology,2011,794 [17] Wärmländer S. Imino proton exchange in DNA catalyzed by ammonia and trimethylamine: evidence for a secondary long-lived open state of the base pair.. [J].Biochemistry,2000,39(3) [18] Cermak R. Influence of ammonia on sodium absorption in rat proximal colon.. [J].Pfluegers Archiv,2000,440(4) [19] Lv Yuan-Yuan. [Preparation of a zinc porphyrinated nanofibrous membrane and its ammonia sensing property].. [J].Zhejiang Daxue Xuebao (Yixue Ban),2012,41(3) [20] Fico M E. Species comparison of the influence of ammonia on orotic acid and urea biosynthesis in liver.. [J].The Journal of Nutrition,1984,114(3) 4.High-accuracy continuous airborne measurements of greenhouse gases (CO<sub>2</sub> and CH<sub>4</sub>) using the cavity ring-down spectroscopy (CRDS) technique 作者:H. Chen ,  J. Winderlich ,  C. Gerbig ,  A. Hoefer ,  C. W. Rella ,  E. R. Crosson ,  A. D. Van Pelt ,  J. Steinbach ,  O. Kolle ,  V. Beck ,  B. C. Daube ,  E. W. Gottlieb ,  V. Y. Chow ,  G. W. Santoni ,  S. C. Wofsy 刊名:Atmospheric Measurement Techniques, 2010, Vol.3 (2), pp.375 来源数据库:DOAJ期刊 原始语种摘要:High-accuracy continuous measurements of greenhouse gases (CO2 and CH4) during the BARCA (Balanço Atmosférico Regional de Carbono na Amazônia) phase B campaign in Brazil in May 2009 were accomplished using a newly available analyzer based on the cavity ring-down spectroscopy (CRDS) technique. This analyzer was flown without a drying system or any in-flight calibration gases. Water vapor corrections associated with dilution and pressure-broadening effects for CO2 and CH4 were derived from laboratory experiments employing measurements of water vapor by the CRDS analyzer. Before the campaign, the stability of the analyzer was assessed by laboratory tests under simulated flight conditions. During the campaign, a comparison of CO2 measurements between the CRDS analyzer and a nondispersive infrared (NDIR) analyzer on board the same aircraft showed a mean difference of 0.22±0.09 ppm for all flights over the Amazon rain forest. At the end of the campaign, CO2 concentrations of the synthetic calibration gases used by the NDIR analyzer were determined by the CRDS analyzer. After correcting for the isotope and the pressure-broadening effects that resulted from changes of the composition of synthetic vs. ambient air, and applying those concentrations as calibrated values of the calibration gases to reprocess the CO2 measurements made by the NDIR, the mean difference between the CRDS and the NDIR during BARCA was reduced to 0.05±0.09 ppm, with the mean standard deviation of 0.23±0.05 ppm. The results clearly show that the CRDS is sufficiently stable to be used in flight without drying the air or calibrating in flight and the water corrections are fully adequate for high-accuracy continuous airborne measurements of CO2 and CH4. 相似文献: [1] Kamahori M. Capillary array electrophoresis analyzer.. [J].Methods in Molecular Biology,2001,163 [2] Fernandes B. Performance characteristics of the Sysmex XT-2000i hematology analyzer.. [J].Labora
展开阅读全文

开通  VIP会员、SVIP会员  优惠大
下载10份以上建议开通VIP会员
下载20份以上建议开通SVIP会员


开通VIP      成为共赢上传

当前位置:首页 > 包罗万象 > 大杂烩

移动网页_全站_页脚广告1

关于我们      便捷服务       自信AI       AI导航        抽奖活动

©2010-2026 宁波自信网络信息技术有限公司  版权所有

客服电话:0574-28810668  投诉电话:18658249818

gongan.png浙公网安备33021202000488号   

icp.png浙ICP备2021020529号-1  |  浙B2-20240490  

关注我们 :微信公众号    抖音    微博    LOFTER 

客服