收藏 分销(赏)

NI 用于InstrumentStudio手册的电子电源验证插件.pdf

上传人:曲**** 文档编号:230165 上传时间:2023-03-20 格式:PDF 页数:15 大小:454.51KB
下载 相关 举报
NI 用于InstrumentStudio手册的电子电源验证插件.pdf_第1页
第1页 / 共15页
NI 用于InstrumentStudio手册的电子电源验证插件.pdf_第2页
第2页 / 共15页
NI 用于InstrumentStudio手册的电子电源验证插件.pdf_第3页
第3页 / 共15页
NI 用于InstrumentStudio手册的电子电源验证插件.pdf_第4页
第4页 / 共15页
NI 用于InstrumentStudio手册的电子电源验证插件.pdf_第5页
第5页 / 共15页
点击查看更多>>
资源描述

1、Electronics Power Validation Add-On for Instrumentstudio2023-03-01Electronics Power Validation Add-On for InstrumentStudioContentsElectronics Power Validation Add-On for InstrumentStudio Manual.3Launching the Electronics Power Validation Add-On from InstrumentStudio.3Large Panel Overview.4Taking a M

2、easurement.5Logging Data.6Saving a Configured Measurement.7Loading a Configured Measurement.7Pin Maps.7Creating a New Pin Map.8Editing a Pin Map.8Importing and Exporting Configurations as MS Excel Files.9Defining an Electronics Power Validation Add-On Project in a Microsoft ExcelSpreadsheet.9Channel

3、 Mapping Worksheet.10Current Worksheet.11Voltage-Voltage Worksheet.12Source-Measurement Worksheet.13Formula Worksheet.14/Electronics Power Validation Add-On for InstrumentstudioEectronics Power VaHdation Add-On for Instrumentstudio ManuaThe Electronics Power validation Add-On for Instrumentstudio he

4、lps you acquire,visualize,and analyze power consumption and measurement data from PXI instruments.This manual contains only information about the Electronics Power validation Add-On.Refer to the InstrumentStudio Manual for information about navigating,configuring,and using InstrumentStudio.2022-2023

5、 National Instruments Corporation.All rights reserved.Refer to the _Legal Information directory for information about Nl copyright,patents,trademarks,warranties,product warnings,and export compliance.Launching the Electronics Power Validation Add-On from InstrumentStudioComplete the following steps

6、to open the Electronics Power validation Add-On from InstrumentStudio.1.Launch InstrumentStudio.|Note InstrumentStudio version 2022 Q4 or later is required.2.Click Manual Layout on the InstrumentStudio home screen to open the Edit Layout dialog box.3.Find Power Validation within the Nl Electronics P

7、ower validation dialog box.4.Select Create large panel from the drop-down menu for the Power Validation Add-On.National InstrumentsElectronics Power Validation Add-On for Instrumentstudio5.Click OK.After you click OK,Instrumentstudio launches the Electronics Power validation Add-On home screen/large

8、 panel.From this home screen,you can select your connected device from the hardware list and configure any channels before starting the acquisition.Large Panel OverviewThe large panel displays connected devices,configured channels,measurement parameters,and acquisitions.Use this panel to configure m

9、easurements,view applications,capture data,view data,and log data for voltage,current,and power measurements.The large panel includes the following options.Run:Starts or stops an acquisition.Mode:Sets the acquisition to be either continuous or finite.For finite acquisitions,specify time the Test Tim

10、e in seconds.Add Channel:Clicking Add Channel configures terminals or pins at which you can measure signals.Channels also encapsulate channel-specific information such as the voltage range that formats the data.Note To duplicate one or more added channels,including their configuration,right click th

11、e channel or channels to be duplicated in the large panel,and use Copy and Paste.To select multiple channels,hold the key and then click on any channels you want to copy and paste.Start/Stop Log:Begins logging or recording data.Search:Lists the compatible devices detected by the Electronics Power Va

12、lidation Add-On.Trigger:Lists the actions that cause Electronics Power validation Add-On to mark or begin an acquisition on a specified channel.You can specify the type of trigger and whether the trigger occurs if the Slope is rising or falling and the Level at which a trigger will occur.4 Electroni

13、cs Power Validation Add-On for Instrumentstudio Dynamics Graphs:Displays channel-specific waveform data such as the mean,minimum,and maximum waveform values.Instrument view(n):Displays the terminal connections(pinouts)for any connected device.List view(目):Shows the connections as a list for any conn

14、ected device.Related tasks:Taking a Measurement Logging DataTaking a MeasurementBefore you begin this procedure,launch the Electronics Power Validation Add-On and open your project.Complete the following steps to take a measurement.1.Click the device tab for any connected DAQ or SMU devices.Note For

15、 DAQ devices,click Add Channel to configure and include additional channels in your measurement.2.Configure each channel by doing one of the following:From the instrument view,double click a channel row or click the gear icon(a).In the pop-up window,select if the channel will measure voltage or curr

16、ent,specify the range,and for current measurements,specify a shunt resistor value.From the list view,click the channel to be configured(for instance,AI0+).In the pop-up window,select if the channel will measure voltage or current,specify the range,and for current measurements,specify a shunt resisto

17、r value.3.Use Mode to specify whether the measurement will be continuous or finite.If it is finite,specify the Test Time in seconds.4.For DAQ devices,select the Trigger to use and the Sampling rate.National InstrumentsElectronics Power Validation Add-On for Instrumentstudio5.For devices that support

18、 offset adjustments,specify either Auto Zero or Chopping values.Auto Zero uses sampling to adjust the offset whereas Chopping uses modulation and demodulation.Chopping and Auto Zero cannot be used together.6.Click Run/Stop to start the acquisition.Your acquisition begins.You can view the acquisition

19、 in progress by clicking the Dynamics Graphs tab and then selecting the channels to view.|Note Click Save to store your 叩plication to be reloaded again later.Related concepts:Large Panel OverviewLogging DataBefore you begin this procedure,launch the Electronics Power validation Add-On to open your p

20、roject in the large panel,and configure any voltage,current,and power measurements for any connected channels.Complete the following steps to capture and record data.1.Configure logging by clicking the gear icon(fi).This opens the Logging specification window.2.In the Logging specification window,se

21、lect an output path,specify if you want files segmented by time or file size,and configure CSV file formatting.3.Click Okay to close the Logging specification window and return to the large panel.4.Click Run/Stop to start acquiring data.5.For finite measurements,specify the acquisition duration by s

22、etting the Mode to Finite and entering the Test Time in seconds.6.Choose one of the following:To manually control a recording,click Start Log to begin capturing data.6 Electronics Power Validation Add-On for Instrumentstudio To automatically start a recoding,click Run.7.For continuous measurements,c

23、lick Run/Stop to end recording data.For finite measurements,the recording ends when the capture duration is completed.Related concepts:Large Panel OverviewSaving a Configured MeasurementTo save a configuration,do the following.Select File Save or File Save all.The configuration file is saved as a.sf

24、p file included in the project(.inststudioproj file).Note When closing Instrumentstudio,the Electronics Power validation Add-On also prompts you to save the configuration.Loading a Configured MeasurementTo reuse a saved configuration,do the following.1.Click Load to add a saved configuration.2.Navig

25、ate to the location where the configuration is saved,and double click the instudioproj file.The saved sampling rate,voltage range,trigger,signal connections,and channels are displayed on the large panel.Note When opening Instrumentstudio,the last project saved is automatically re-opened.Pin MapsPin

26、maps define test instruments and hardware,sites and pins connected to a DUT,and how the test instruments and hardware connect to DUT pins for each test site.National InstrumentsElectronics Power Validation Add-On for InstrumentstudioInstrumentstudio preserves mappings created in Test Stand Semicondu

27、ctor Module(TSM)pin maps.Refer to the other topics in this section of the manual for specific information on how to create and modify pin maps.Creating a New Pin MapTo create a Pin Map,use the Pin Map Editor in Instrumentstudio:1.Select File New Pin Map or click Add in the project files pane toolbar

28、to create a new pin map file(.pinmap).2.Use the Pin Map Editor to configure your pin mappings.The Pin Map tab displays mappable items.Use the left pane to browse through and configure the mappings you want to include in your pin map.To manually edit the pin map file text,click the XML tab.Note If yo

29、u are working in an unsaved project,Instrumentstudio will prompt you to save the project before creating a new pin map.3.Click OK to close the editor and return to your project.The new pin map is now the active project pin map.e NoteWhen activating a pin map file,the channel names change from the in

30、itial channel name to the linked pin name as configured in the pin map file.Editinga Pin MapUse the Pin Map Editor to make changes to a project pin map.1.Double-click a pin map(.pinmap)in the project files pane to open the Pin Map Editor.2.Make the desired changes to your instruments,connections,and

31、 pins.Use the Pin map tab to view mappable items and change mappings.To manually change the pin map file,click the XML tab and to edit the pin map.8 Electronics Power Validation Add-On for InstrumentstudioWhen you have completed your edits,click OK to close the Pin Map Editor.Importing and Exporting

32、 Configurations as MS Excel FilesFor high-channel systems,such as a structural test,you might want to specify the test system in a Microsoft Excel spreadsheet instead of directly in the Electronics Power Validation Add-On.Using an Excel spreadsheet allows you to use the built-in mass edit capabiliti

33、es of Excel as well as provide a more common format for sharing with others.To import an Excel file or export the current configuration to a Microsoft Excel file,do the following.1.Click Import/Export.2.Do one of the following:To import an existing configuration,navigate to the location where the co

34、nfiguration is saved,and double click the instudioproj file.The saved sampling rate,voltage range,trigger,signal connections,and channels are displayed on the large panel.To export,navigate to location where you want the current configuration saved.Note When opening Electronics Power Validation Add-

35、On,the last project saved is automatically re-opened.Related tasks:Defining an Electronics Power Validation Add-On Project in a Microsoft Excel Spreadsheet National InstrumentsElectronics Power Validation Add-On for InstrumentstudioDefining an Electronics Power Validation Add-On Project in a Microso

36、ft Excel SpreadsheetUse a Microsoft Excel spreadsheet(.xlsx)to define and configure an Electronics Power Validation Add-On project so you can import it into Electronics Power Validation Add-On.Complete the following steps to define your Electronics Power Validation Add-On project in an Excel spreads

37、heet.1.Create an Excel spreadsheet with the following worksheets:Required:Channel Mapping Optional:Current Voltage-Voltage Source-Measurement Formulas2.Set up the Channel Mapping worksheet.Refer to Channel Mapping Worksheet to learn about what to name the columns,which columns are required,and what

38、values are allowed for each column.3.(Optional)Set up the Current,Voltage-Voltage,Source-Measurement,and Formula worksheets with the appropriate columns.4.Save the file in.xlsx format.Note The Excel file format supported is the same as FlexLogger supports with a few limitations.Refer to http: find o

39、ut more.Related tasks:Importing and Exporting Configurations as MS Excel Files10 Electronics Power Validation Add-On for InstrumentstudioChannel Mapping WorksheetFor each channel you create on the Current,Voltage-Voltage,and Source-Measurement worksheets,create the hardware lookup on the Channel Map

40、ping worksheet to specify the device to which you want to add the channel.Set up the Channel Mapping worksheet with the columns described in the following table.Table 1.Channel Mapping WorksheetColumn NameColumn TypeAllowed ValuesChannel NameRequiredChannel Name specified in another worksheet,such a

41、s the Voltage-Voltage worksheet.Device ModelRequired PXIe-4309 PXIe-4139Device NameRequiredUnique string,such as cDAQlDevice Serial NumberOptionalUnique string that maps to the chassis serial number,such as 123ALPHAModule ModelRequired Nl9220 Nl9252Module Slot NumberRequiredThe module slot in the ch

42、assis,from 1 to n(depending on the number of slots available in the chassis)Channel NumberRequiredThe physical name of the channel on the module,from aiO to ain(depending on the number of channels available on the module)Current WorksheetCreate the current worksheet for the modules in your system.Se

43、t up this worksheet with the columns described in the following table.National InstrumentsElectronics Power Validation Add-On for InstrumentstudioTable 2.Current WorksheetColumn NameColumn TypeAllowed ValuesChannel NameRequiredString that does not contain the following characters:Channel names must

44、be unique.Signal RangeOptional Automatic Manual(;)Range is expressed in parenthesis,with the minimum and maximum double values separated by a semicolon.Shunt Resistor ValueRequiredExpress value in Ohms.Data Rate(Hz)Optional Slow()Medium()Fast()Voltage-Voltage WorksheetCreate the Voltage-Voltage work

45、sheet for the NI-9213 and NI-9215 modules in your system.Set up this worksheet with the columns described in the following table.Channel Name Required String that does not contain thefollowing characters:Column Name Column TypeAllowed Values上 Electronics Power Validation Add-On for InstrumentstudioC

46、olumn NameColumn TypeAllowed Values Channel names must be unique.Signal RangeOptional Automatic Manual(;)Range is expressed in parenthesis,with the minimum and maximum double values separated by a semicolon.Data Rate(Hz)Optional Slow()Medium()Fast()Table 3.Voltage-Voltage WorksheetSource-Measurement

47、 WorksheetCreate the Source-Measurement worksheet for any modules in your system.Set up this worksheet with the columns described in the following table.Column NameColumn TypeAllowed ValuesChannel NameRequiredString that does not contain the following characters:National InstrumentsElectronics Power

48、 Validation Add-On for InstrumentstudioTable 4.Source-Measurement WorksheetColumn NameColumn TypeAllowed ValuesChannel names must be unique.Physical UnitRequiredMust be expressed as Volt(V)or Amp(A).Signal RangeOptional Automatic Manual(;)Range is expressed in parenthesis,with the minimum and maximu

49、m double values separated by a semicolon.Output ValueRequiredMust be expressed as Volt(V)or Amp(A).Limit(Amp or Voltage)OptionalVoltage Gain Bandwidth(Hz)OptionalVoltage Gain Frequency(Hz)OptionalVoltage Pole-RatioOptionalCurrent Gain Bandwidth(Hz)OptionalCurrent Gain Frequency(Hz)OptionalCurrent Po

50、le-RatioOptionalFormula WorksheetCreate the Formula worksheet for the modules in your system.Set up this worksheet with the columns described in the following table.Column NameColumn TypeAllowed ValuesChannel NameRequiredChannel Name specified in another worksheet,such as the Voltage-Voltage workshe

展开阅读全文
相似文档                                   自信AI助手自信AI助手
猜你喜欢                                   自信AI导航自信AI导航
搜索标签

当前位置:首页 > 应用文书 > 其他

移动网页_全站_页脚广告1

关于我们      联系我们       自信AI       AI导航        获赠5币

©2010-2024 宁波自信网络信息技术有限公司  版权所有

客服电话:4008-655-100  投诉/维权电话:4009-655-100

gongan.png浙公网安备33021202000488号  |  icp.png浙ICP备2021020529号-1 浙B2-2024(办理中)  

关注我们 :gzh.png    weibo.png    LOFTER.png 

客服