资源描述
附件C1:Annex C1
建筑消防设施巡查记录表
Inspection record table for building fire protection facilities
序号:
NO:
巡查项目
item
巡 查 内 容
content
巡 查 情 况
Situation
部位
Part
数量
Qty.
正常
Normal
故障及处理
Fault
故障描述
Description
当场处理情况
On-site handling state
报修情况
Repair
消防供配电设施
Fire power supply and distribution
消防电源主电源、备用电源工作状态
Status of main power and standby power
发电机启动装置外观及工作状态
The appearance and working state of the generator starting device
消防配电房、UPS电池室、发电机房环境
The environment of power distribution room, UPS battery room, generator room
消防设备末端配电箱切换装置工作状态
Working status of power distribution switch box for firefighting equipment
火灾自动报警系统
Fire automatic alarm system
火灾探测器、手动报警按钮、信号输入模块、控制模块外观及运行状态
The appearance and operation state of fire detector, manual alarm button, signal input module and control module.
火灾报警控制器、火灾显示盘、CRT图形显示器运行状况
Operation status of fire alarm controller, fire display panel and CRT graphic display
消防联动控制器外观及运行状况
Appearance and operation status of fire linkage controller
火灾报警装置外观
Appearance of fire alarm device
建筑消防设施远程监控、信息显示、信息传输装置外观及运行状况
Appearance and operation status of remote monitoring, information display and information transmission device for building fire facilities
系统接地装置外观
System appearance of grounding device
消防控制室工作环境
Work environment of fire control room
电气火灾监控系统Electric fire monitor system
电气火灾监控探测器的外观及工作状态
Appearance and working state of electric fire detector
报警主机外观及运行状态
Appearance and working state of the alarm host
可燃气体探测报警系统Combustible gas detection and alarm system
可燃气体探测器的外观及工作状态
Appearance and working state of combustible gas detectors
报警主机外观及运行状态
Appearance and working state of the alarm host
消防供水设施
Fire water supply facilities
消防水池、消防水箱外观,液位显示装置外观及运行状况,天然水源水位、水量、水质情况,进户管外观
Appearance of fire water pool and fire water tank, appearance and operation status of water level display device;
Level, volume and quality of natural source of water;
Appearance of water pipe
消防水泵及控制柜工作状态
Working state of fire pump and control cabinet
稳压泵、增压泵、气压水罐及控制柜工作状态
Working state of steady pressure pump, booster pump, pneumatic water tank and control cabinet
水泵接合器外观、标识
Appearance and identity plate of pump connector
系统减压、泄压装置、测试装置、压力表等外观及运行状况
Appearance and working state of pressure reduce/relief system, test devices, pressure gauges, etc.
管网控制阀门启闭状态
Opening and closing state of pipe control valve
泵房照明、排水等工作环境
Lighting and drainage of the pump house
消火栓(消防炮)灭火系统
Fire hydrant (Fire monitor) system
室内消火栓、消防卷盘外观及配件完整情况
Appearance and accessories integrity of indoor fire hydrant and fire reel
屋顶试验消火栓外观及配件完整情况、压力显示装置外观及状态显示
Appearance and accessories integrity of roof test hydrant;
Appearance and status of pressure display device
室外消火栓外观、地下消火栓标识、栓井环境
Appearance of exterior hydrant, marking of underground fire hydrant, environment of fire hydrant chamber
消防炮、炮塔、现场火灾探测控制装置、回旋装置等外观及周边环境
The appearance and surrounding environment of Fire monitor, turret, field fire detection control device, gyratory device
启泵按钮外观
Appearance of pump button
自动喷水灭火系统Automatic sprinkler system
喷头外观及距周边障碍物或保护对象的距离
Appearance of sprinkler and the distance from the surrounding obstacles or protection objects
报警阀组外观、试验阀门状况、排水设施状况、压力显示值
Appearance of the alarm valve group, the state of the test valve, the state of the drainage facilities, and the indication value of the pressure
充气设备及控制装置、排气设备及控制装置、火灾探测传动及现场手动控制装置外观及运行状况
Appearance and operation status of aerated equipment and control devices, exhaust equipment and control devices, fire detection drive and field manual control devices.
楼层或区域末端试验阀门处压力值及现场环境,系统末端试验装置外观及现场环境
Pressure value and field environment of terminal test valve on floors/in areas;
Appearance and field environment of system terminal test device on floors/in areas
泡沫灭火系统
Foam extinguisher
泡沫喷头外观及距周边障碍物或保护对象距离
Appearance of foam sprinkler and distance from surrounding obstacles or protection objects
泡沫消火栓、泡沫炮、泡沫产生器、泡沫比例混合器外观
Appearance of foam hydrant, foam gun, foam generator and foam proportioning mixer
泡沫液贮罐外观及罐间环境,泡沫液有效期及储存量
Appearance and environment of foam tank;
Validity date of foam liquid; storage capacity
控制阀门外观、标识,管道外观、标识
Appearance and identity plate of control valve and pipe
火灾探测传动控制、现场手动控制装置外观、运行状况
Appearance and operation status of fire detection drive control system and field manual control device
泡沫泵及控制柜外观及运行状况
Appearance and operation status of foam pump and control cabinet
冷却水系统的巡查内容可参考6.2.7
The inspection content of the cooling water system can be referred to 6.2.7
气体灭火系统
Gas fire extinguishing system
气体灭火控制器外观、工作状态
Appearance and working state of gas extinguisher controller
储瓶间环境,气体瓶组或储罐外观,检漏装置外观、运行状况
Environment of the storage tank;
Appearance of the gas cylinder or storage tank;
Appearance and operation state of the leak detector.
容器阀、选择阀、驱动装置等组件外观
Appearance of components such as container valves, selector valves and driving devices
紧急启/停按钮外观,喷嘴外观、防护区状况
Appearance of emergency start/stop button and nozzle; Condition of protection area
预制灭火装置外观、设置位置、控制装置外观及运行状况
Appearance of pre-fabricated fire extinguishing system; setting position; appearance and operation state of control device
放气指示灯及警报器外观
Appearance of gas release indicator light and alarm
低压二氧化碳系统制冷装置、控制装置、安全阀等组件外观、运行状况
Appearance and operation state of components such as refrigeration devices, control devices and safety valves for low pressure carbon dioxide systems
防烟、排烟系统
Smoke prevention and exhaust system
送风阀外观
Appearance of air supply valve
送风机及控制柜外观及工作状态
Appearance and working state of air blower and control cabinet
挡烟垂壁及其控制装置外观及工作状况、排烟阀及其控制装置
外观
The appearance and working state of smoke retaining wall and its control device; the appearance of smoke exhaust valve and its control device
电动排烟窗、自然排烟设施外观
Appearance of electric smoke window, natural smoke exhaust facilities
排烟机及控制柜外观及工作状况
Appearance and working state of smoke exhauster and control cabinet
送风、排烟机房环境
Appearance and working state of smoke exhauster and control cabinet
应急照明和疏散指示标志
Emergency lighting and evacuation indicator
应急灯具外观、工作状态
Appearance and working state of emergency lamps and lanterns
疏散指示标志外观、工作状态
Appearance and working state of the evacuation indicator
集中供电型应急照明灯具、疏散指示标志灯外观、工作状况,集中电源工作状态
Appearance and working state of centralized power supply emergency lighting, evacuation indicator lights;
Working state of centralized power supply
字母型应急照明灯具、疏散指示标志灯外观、工作状态
The appearance and working state of letter type emergency lighting and evacuation indicating lights
应急广播系统
Emergency broadcasting system
扬声器外观
Appearance of loudspeaker
功放、卡座、分配盘外观及工作状态
The appearance and working state of power amplifier, cassette tape deck and distribution plate
消防专用电话
Firefighting telephone
消防电话主机外观、工作状况
Appearance and working condition of firefighting telephone host
分机电话外观,电话插孔外观,插孔电话机外观
Appearance of the extension telephone; Appearance of telephone jack, the appearance of jack phone.
防火分隔设施
Fireproof facility
防火窗外观及固定情况
Appearance and fixation of fireproof windows
防火门外观及配件完整性,防火门启闭状况及周围环境
Fire door appearance and accessories integrity;
Fire door opening and closing situation and surrounding environment
电动型防火门控制装置外观及工作状态
Appearance and working condition of electric fire door control device
防火卷帘外观及配件完整性,防火卷帘控制装置外观及工作状况
Fire shutter appearance and accessories integrity; fire shutter control device appearance and working condition
防火墙外观
Firewall appearance
防火封堵外观
Fire prevention and closure appearance
消防电梯
Fire elevator
紧急按钮外观,轿箱内电话外观
Emergency button appearance, telephone appearance in the elevator car
电梯井排水设施外观及工作状况
Appearance and working condition of drainage facilities in elevator shaft
消防电梯工作状况
Working state of fire elevator
细水雾灭火系统
Water mist fire-extinguishing system
灭火控制器工作状态
Working state of the fire extinguisher controller;
储气瓶和储水瓶(或储水罐)外观、工作环境
Appearance and working environment of gas cylinders and water storage tank
高压泵组、稳压泵外观及工作状态,末端试水装置压力值(闭式系统)
Appearance and working state of the high pressure pump group and the steady pressure pump;
Pressure value of the terminal water test device (closed system)
紧急启/停按钮、释放指示灯、报警器、喷头、分区控制阀等组件外观
Appearance of emergency start/stop button, indicator of release, alarm, sprinkler, partition control valve and other components
防护区状况
Condition of protection zone
干粉灭火系统
Dry powder fire extinguishing system
灭火控制器工作状态
Working state of the fire extinguisher controller
设备储存间环境、驱动气瓶和灭火剂储存装置外观
Equipment storage room environment; appearance of driving cylinder and extinguisher storage device
选择阀、驱动装置等组件外观
Appearance of selector valves and driving devices
紧急启/停按钮、放气指示灯、警报器、喷嘴外观
Appearance of emergency start/stop button, indicator of release, alarm, sprinkler
防护区状况
Condition of protection zone
灭火器
Fire extinguisher
灭火器外观
Appearance of fire extinguisher
设置位置状况
Status of setting position
其他设施
Other facilities
巡查人(签 名)
Inspecting person (signature)
年 月 日
Date
消防安全管理人(签名)
Fire Safety Manager (signature)
年 月 日
Date
备注
Remarks
注:1、情况正常打“√”,存在问题或故障的打“×”,并填写“故障及处理”栏中相关内容;
Note: 1. If the situation is normal, put a tick. If not, put a cross and fill the ‘Fault’ part.
2、对发现的问题和故障应及时处理,当场不能处置的要填报《建筑消防设施故障维修记录表》;
2, The problem/failure should be dealt with in time. If inspector cannot handle the problem/failure on-site, he shall fill in sheet‘Record of building fire service failure maintenance’.
3、本表为样表,单位可根据建筑消防设施实际情况和巡查时间段制表。
3. The table is a template. The social unit can make own table according to the actual situation of the building fire protection facilities and the inspection time.
[此文档可自行编辑修改,如有侵权请告知删除,感谢您的支持,我们会努力把内容做得更好]
最新可编辑word文档
展开阅读全文