收藏 分销(赏)

2.-E4503-00B-S洗瓶机清洁规程英文翻译.doc

上传人:仙人****88 文档编号:12019563 上传时间:2025-08-28 格式:DOC 页数:7 大小:138KB 下载积分:10 金币
下载 相关 举报
2.-E4503-00B-S洗瓶机清洁规程英文翻译.doc_第1页
第1页 / 共7页
2.-E4503-00B-S洗瓶机清洁规程英文翻译.doc_第2页
第2页 / 共7页


点击查看更多>>
资源描述
Title Cleaning Procedures of B+S Bottle Washing Machines Reg. No.:E4503-00 Effective Date: Page:7 /6 Standard Operation Procedure Title: Cleaning Procedures of B+S Bottle Washing Machines Reg. No.:E4503-00 Page:1/6 Prepared by : Date: Reviewed by: Date: Approved by: Date: Effective Date: Expiry Date: First Delay: Second Delay: Revision History No. Reg. No. Writer Summary 1 E4503-00 Hui Yanjiang New SOP Distribution Production Management Dept., Formulation Workshop2, Equipment Dept., QA Dept. Catalogue Page 1. Purpose…………………………....................................………………………………….04 2. Scope and device description……………….....................................……………..….04 3. Treatment procedures…………………….......……………………………………..…04 4. Notes……………….................................…………………………………………..… 06 5. Reference…………………….................................…………………………………..…06 6. SOP Concerned…………………………………………………………………………06 7. Attachments……………………….................................…………………………….. 06 1. Purpose To describe the cleaning methods of B + S bottle washing machines. 2. Scope and device description This SOP is suitable for the cleaning of the B+S bottle washing machines in the formulation workshop2. Place Device model Manufacturer Fixed assets’ number Formulation workshop2 FAW1020 Germany B+S Company S09640801 3. Treatment procedures 3.1 The cleaning before washing bottles 3.11 The cleaning of bottle washing machines Open the compressed air valve. Turn on the general power of the washing machine. Turn number 3 on the control panel to the right to raise its shield (See the following picture). 3.1.1.1 Check whether there are Penicillin bottles, broken bottles and glass debris of last batch remaining in the washing machine. If there are some remains, clean them. First, dip in water for injection with clean cloth, and wipe the area where Penicillin bottles touches the washing machine directly (Such as the turntable of the coming-in bottles, the track of the coming-in bottle, the track of the going-out bottles, the bottle gripping module, etc). Wipe at least three times until there are no visible debris. 3.1.1.2 Next, dip in water for injection with clean cloth, and wipe the surface of washing machine internal components and the inside of its shield at least three times until there are no visible debris. 3.1.1.3 Then, dip in water for injection with clean cloth, and wipe the outside surface of washing machine including the outside of its shield, its external pipelines at least three times until there are no visible debris. 3.1.1.4 Wipe the touch screen and control panel gently with a clean cloth dipped in water for injection. 3.1.2 The cleaning of circulatory water tanks 3.1.2.1 Remove the lid of the circulatory water tank. Then check whether there is water remaining. If so, empty the water inside. 3.1.2.2 Wipe the surface of the tank, including its drainage wedge, with a clean cloth dipped in water for injection at least three times until there are no visible impurities. 3.1.2.3 Then put away the wedge, put on the lid, and wipe the outside surface of the tank at least three times. 3.2 The cleaning after washing bottles 3.2.1 The cleaning of bottle washing machines Please make sure that the shield of the bottle washing machine has been raised to the specified location. 3.2.1.1 Clean up the remaining Penicillin bottles, broken bottles and glass debris after production. First, use a clean cloth soaked in 65% ethanol solution to wipe the area where Penicillin bottles touches the washing machine directly (Such as the turntable of the coming-in bottles, the track of the coming-in bottle, the track of the going-out bottles, the bottle gripping module, etc). Wipe at least three times until there are no visible impurities. 3.2.1.2 Next, use a clean cloth soaked in 65% ethanol solution to wipe the surface of washing machine internal components at least three times. 3.2.1.3 Then, dip in water for injection with clean cloth, and wipe the inside and outside of its shield, and its external pipelines at least three times. 3.2.2 The cleaning of circulatory water tanks 3.2.2.1 Remove the lid of the circulatory water tank. Then pull out the wedge in order to empty the water inside. 3.2.2.2 Wipe the surface of the tank, including its drainage wedge switch, with a clean cloth dipped in water for injection at least three times until there are no visible impurities. 3.2.2.3 Then put the wedge switch in its place, put on the lid, and wipe the outside surface of the circulatory water tank at least three times. 3.2.3 Turn number 3 on the control panel to the left to lower its shield to the end. Turn off the general power switch and close the compressed air valve. 3.2.3 Complete the records of devices’ cleaning and sterilization. ( See E1011F02XX) 4. Notes 4.1 Use a clean cloth dipped in water for injection to clean the plexiglass shields of the circulatory water tanks and the bottle washing machines before and after the clearance., 4.2 Refrain from being scratched by broken glass every time you wipe. 4.3 Refrain from touching the electric eye every time you wipe. 4.4 Make sure that you activate any function button when you wipe the control panel. And refrain from scratching the touch screen. w5. Reference B+S full-automatic cleaning device instructions B+S recirculation system instructions 6. SOP concerned General cleaning procedures of devices for production (EB-098-X;E1011-XX) 7. Attachments None
展开阅读全文

开通  VIP会员、SVIP会员  优惠大
下载10份以上建议开通VIP会员
下载20份以上建议开通SVIP会员


开通VIP      成为共赢上传

当前位置:首页 > 品牌综合 > 行业标准/行业规范

移动网页_全站_页脚广告1

关于我们      便捷服务       自信AI       AI导航        抽奖活动

©2010-2026 宁波自信网络信息技术有限公司  版权所有

客服电话:0574-28810668  投诉电话:18658249818

gongan.png浙公网安备33021202000488号   

icp.png浙ICP备2021020529号-1  |  浙B2-20240490  

关注我们 :微信公众号    抖音    微博    LOFTER 

客服