资源描述
Click to edit Master title style,Click to edit Master text styles,Second level,Third level,Fourth level,Fifth level,8/13/2013,#,Agenda,议程,2.Fire Safety Requirement Enhancement Legal and Walmart,Standards Sharing,消防要求的提高,法律与,WM,标准的分享,电气安全同等与消防,,30day,改善,As part of our effort to work with suppliers globally to,Facilities to have fire safety related violations must,Initiate corrective actions immediately.All repairs or,Changes that are not able to be completed immediately,Must be completed no later than thirty(30)days from,Identification.During this thirty-day period,the factory,Must implement plans to mitigate the identified risks or,Further production will be barred.,一旦发现工厂设施存在消防方面的违法行为,工厂应立即采取整,改措施。如果修理或更正无法立即完成,则应该在确认后三十,(,30,)日内完成。在此三十日的期限内,工厂必须采取方案降低,已确认的风险,否则工厂应停工。,In addition,there is a certain set of requirements which,may be above and beyond legal requirement(s)that must,be implemented and adhered to.These include:,此外,还应执行和遵守一系列高于或独立于法定要求之外的其他,要,求,这些要求包括:,Content,:,No locked doors.Doors should have push bar operation for easy exit in case of emergency.,门不可锁死。门应该有门推手以便在紧急情况下易于操作,。,Barred windows must have an internal mechanism for,e,mergency release or removal to allow for worker escape,a,nd must remain unlocked.,有木栅的窗户必须有内部的装置以便紧急情况下可以打开或卸下木栅以便工人逃生,且应保持不上锁状态。,All floors and buildings,including dormitories,must have,a,secondary exit,and preferably an,e,xternal fire escape,r,oute,including dormitories,包括宿舍的所有建筑的所有楼层,必须要有第二出口和优先外部逃生路线。,Fire escape routes must lead to safe assembly points without any obstructions.Assembly points must be designated and marked as such and must be kept clear at all times.,火灾逃生路线必须无障碍地通向安全的集合地点。集合地点必须被指定并标明是此用途,且必须不得占用。,Proper access for fire department vehicles and other firefighting equipment in the factory,p,remises.,应为消防车和消防器材进出工厂留出通路。,Adequate water supply for sprinkler and fire hydrant systems.,应有足够的水源供喷淋和消防栓使用。,Audible,visible and operable smoke alarms placed,appropriately throughout the building with at least the minimum number required by law.Audible and operable fire alarms that can be heard in all parts of the building,that operate as one system amongst all floors and areas of the building.,应该在建筑物范围内合适地方设置不少于法定要求数量的可听、可视、可操作的烟雾报警器。火灾报警器应在建筑物范围内任何位置都能被听到,且可在各楼层和建筑物所有区域范围内可作为一个系统进行操作。,Content,:,Marked and lighted exit routes for all floors and areas of the building,including stairwells.Emergency lights to be fire grade industrial emergency lights for use in smoke and fire environments.,所有楼层及建筑物任何位置,包括楼梯,应有明确标志和闪亮 的出口路线,应急灯在有烟或火的环境下,达到“工业应急灯”的亮度。,Quarterly joint fire drills including all floors of the building to be overseen by an external party,such as the fire authority,for timely and effective personnel evacuation.,每季度进行所有楼层的消防演习,消防演习应由外部第三方(如消防部门)监督所有人员及时有效地进行疏散。工厂应保存好有关消防演习的资料以供到访人员查阅。,Fire safety training conducted for all personnel every 6 months.,Personnel on-boarding process should include fire safety training upon hiring.,Trained firefighters for each floor of the facility.,应每,6,个月对全体人员进行消防安全培训。,人员入职培训应包括消防培训。,工厂每一层设一名受过训练的消防员。,Trained firefighters for each floor of the facility,Valid fire license where required by law.,持有有效的消防许可证(如法律要求),持有有效的建设许可(如法律要求),Hazardous/flammable chemicals must be kept away from,ignition sources,危险化学品或易燃物应远离火源放置。,Creche/childcare facilities must be on the ground floor of,the building,preferably located in a separate non-industrial facility.,育婴所或托儿所必须设于建筑物的首层,如设置于单独的非工业厂房则更佳。,No locked doors.Doors should have push bar operation for easy exit in case of emergency.,门不可锁死。门应该有门推手以便在紧急情况下易于操作。,问题:什么是安全出口?,Question:What is Safety Exit?,安,全出口,Safety exit:,供人员安全疏散的楼梯间,室外楼梯的出入口或直通室内外安全区域的出口,问题:什么是紧急出口?,Question:Whats Emergency Exit?,(Wikipedia)An emergency exit in a structure is a special exit for emergencies such as a fire:the combined use of regular and special exits allows for faster evacuation,while it also provides an alternative if the route to the regular exit is blocked by fire,etc.,It is usually a,strategically located(e.g.in a stairwell,hallway,or other likely place)outward opening door with,a crash bar,on it and,with exit signs leading,to it.The name is a reference to when they are frequently used,however a fire exit can also be a main doorway in or out.,A fire escape is,a special kind of emergency exit,mounted to the outside of a building.,(,维基百科)紧急出口(又称安全出口)一词是指建筑物内有一条特别出口作为紧急用途,例如火警:用作特别逃生通道,容许民众更快从建筑物疏散,出口也提供一个路经来逃离火警现场,紧急出口通常位于一个特别的位置,(例如在楼梯井,走廊位置或其他相关地方)。紧急出口的防火门大多会设有警报装置,防火门上方也会设立出口指示牌。,沃尔玛的理解:,如果安全出口被认定为紧急出口,那么该安全出口应该按照紧急出口设置,问题:,push bar,的作用是什么?,Question,:,Whats the function of push bar?,1,在各种紧急情况下,能够利用人的本能动作将,平时关闭的疏散门打开,迅速逃生:,2.,能够最大限度避免在黑暗、烟雾或混乱状态下,,因为无法打开疏散门而导致人员无法逃生的危险;,3.,能够在紧急情况下,通过声光和语音起到报警,和逃生指引的作用;,4.,在正常情况下,能够起到限制通行、防盗或防,盗报警的作用,在一定程度上解决了消防与安防对,疏散门不同要求之间的矛盾;,5.,在与自动消防、安防或门禁系统联合使用。,安全出口,紧急出口,疏散出口,Question:Whats the requirement for Emergency Door?,问题:紧急疏散门的要求是什么?,Unlocked during work hour -,工作时间保持不上锁状态,Single Motion Door-,既开型门,What is single motion door?,什么事既开型门?,Unlatch door with no more than ONE motion operation -The door is ready to be opened.,不多于一个简单的动作,,即可开闩,/,栓使门处于可打开状态。这个动作可以是:,Turn the lever of a lockset/latch set;,转动锁具的闩,/,栓打开杠杆;,No lockset/latch set but a push bar;,无锁具无闩,/,栓,只有一个推杆;,Push to release lockset/latch set on push bar;,推即可打开推杆锁;,Push on the touchpad of a panic device.,或推动紧急装置上的触摸板。,问题:工厂疏散门的设置要求?,Question,:,What is the requirement of facility evacuation door?,法律要求:,1.,疏散用门应向,疏散方向开启,。,除甲、乙类生产车间外,人数不超过,60,人且,每樘门的平均疏散人数不超过,30,人的房间,,其门的开启方向不限;,2.,疏散用门应采用,平开门,,不应采用,推拉门、卷帘门、吊门、转门和折叠门;,丙、丁、戊类仓库首层靠墙的外侧可采用,推拉门或卷帘门;,3.,疏散门开启时,不应该减少楼梯梯段平台,的有效宽度;,4.,人员密集的场所中平时需要控制人员随意,出入的疏散用门,应保证火灾时不需使用,钥匙等任何工具既能从内部易于打开,并应,在显著位置设置标识和使用提示。,沃尔玛的要求:,1.,疏散门应向疏散方向开启,2.,车间安全出口不可使用卷帘门,/,推拉门,/,吊,门作为疏散门。,一个房间或区域内应设置几个疏散门?,一座公共建筑内的一个建筑面积超过,60m2,的房间,应设置,2,个疏散门。,一层楼一般为一个横向消防分区,应设置几个安全出口?其中的隔间应该设置多少疏散出口?,规范中建议:每层楼至少要有两个安全出口。其中隔间疏散出口数参照相应法规。,什么是疏散门?,疏散门为直接通向疏散走道的门,疏散门有时也是安全出口。,什么是安全出口?,供人员安全疏散用的楼梯间、室外楼梯的出入口或直通室外安全区域的出口。,Question,:,What is the installment requirement for fire resistant door?,问题:工厂防火门的设置要求?,法律要求:,1.,应具有自闭功能。双扇防火门应具有,按顺序关闭的功能;,2.,常开防火门,(,人员经常通过的地方,),应,能在火灾时自行关闭,并应有信号反,馈的功能,3.,防火门内外两侧应能手动开启(除,以下情况外:人员密集的场所中平时,需要控制人员随意出入的疏散用门,,或设置有门禁系统的居住建筑外门,,应保证火灾时不需要使用钥匙等任何,工具即能从内部易于打开,并应在显,著位置设置标识和使用提示。),沃尔玛的要求:,1.,防火门可以常闭,2.,如果通向防烟楼梯间或消防逃生区域,的防火,/,防烟门不能保持关闭,就不,能阻止火灾烟气蔓延,影响人员安全,疏散。,当一层楼是一个防火分区的时候,When one layer=one fire compartment,Work Shop 1,Work Shop 2,普通门,Normal door,普通门,Normal door,Evacuation staircase,疏散楼梯,Evacuation staircase,疏散楼梯,Work Shop 1,Work Shop 2,防火门,Fire resistant door,Evacuation staircase,疏散楼梯,Evacuation staircase,疏散楼梯,当一层楼内有两个以上防火分区的时候,one layer=more than two fire compartment,防火门,Fire resistant door,问题:双向开的安全出口门符合消防的要求?,Question:Can safety door with bidirection live up to fire safety standards?,高层厂房(仓库)、人员密集的公共建筑、人员密集的多层丙类厂房设置封闭楼梯间,时,通向楼梯间的门应采用乙级防火门,并应向疏散方向开启;,其他建筑封闭楼梯间的门可采用双向弹簧门。,问题:两个联通的车间内有一个防火卷帘门,是否要修改?,Question:is it necessary to amend the fire-resistant roller gate which,connect two plants?,问题:工厂有卷帘门,将门锁死在墙上可以吗?,Question:Can factory lock up the roller gate?,详情参考:,建筑设计防火规范,(GB50016-2006),Barred windows must have an internal mechanism for,e,mergency release or removal to allow for worker escape,a,nd must remain unlocked.,有木栅的窗户必须有内部的装置以便紧急情况下可以打开或卸下,木栅以便工人逃生,且应保持不上锁状态。,法律关于防盗网的要求,建筑设计防火规范,(GB50016-2006):,人员密集的多层公共建筑不宜在窗口、,阳台等部位设置金属栅栏,当必须设置,时,应有从内部易于开启的装置。窗口、,阳台等部位宜设置辅助疏散逃生设施。,沃尔玛要求:,有木栅的窗户必须有内部装置以便紧急,情况下可以打开或卸下木栅以便工人逃,生,且应保持不上锁状态。,公共建筑的定义:,公共建筑包含办公建筑、游戏建筑、科教文卫建筑、通信建筑、以及交通运输类建筑;如商场,/,医院,/,火车站,问题:什么类型的宿舍窗户需要设置逃生设施?,Question,:,What type of dormitory windows need to set up evacuation appliance?,All floors and buildings,including dormitories,must have,a,secondary exit,and preferably an external fire escape,r,oute,including dormitories,包括宿舍的所有建筑的所有楼层,必须要有第二出口和优先外,部逃生路线。,问题:工厂的安全出口数量足够吗?,Question:is there enough safety exits?,厂房,/,仓库的每个防火分区、一个防火分区内的每个楼层安全出口的数量应经,计算确定,且不应少于,2,个;当符合下列条件时,可设置,1,个安全出口:,建筑类型,建筑面积(,m2),同时停留,/,经常人数(人),甲类厂房,=100m2,=5,乙类厂房,=150m2,=10,丙类厂房,=250m2,=20,丁、戊类厂房,=400m2,=30,地下、半地下厂房,=50m2,=15,仓库,=300m2,N/A,WM,规定:所有楼层,都必须有第二出口,问题:我的工厂的火灾危险性属于甲,/,乙,/,丙,/,丁,/,戊哪一类?,Question:Which fire risk rating does my factory belong to?,生产类别,使用或产生下列物质的生产的火灾危险特性,甲类,1,闪点,28,的液体,2,爆炸下限,10,的气体,3,常温下能自行分解或在空气中氧化即能导致迅速自燃或爆炸的物质,4,常温下受到水或空气中水蒸气的作用,能产生可燃气体并引起燃烧或爆 炸的物质,5,遇酸、受热、撞击、摩擦、催化以及遇有机物或硫磺等易燃的无机物,极易引起燃烧或爆炸的强氧化物,6,受撞击、摩擦或与氧化剂、有机物接触时能引起燃烧或爆炸的物质,7,在密闭设备内操作温度等于或超过物质本身自燃点的生产,乙类,1,闪点,28,至,60,的液体,2,爆炸下限,10,的气体,3,不属于甲类的氧化剂,4,不属于甲类的化学易燃危险固体,5,助燃气体,6,能与空气形成爆炸性混合物的浮游状态的粉尘、纤维、闪点,60,的液体 雾滴,丙类,1,闪点,60,的液体,2,可燃固体,丁类,1,对非燃烧物质进行加工,并在高热或熔化状态下经常产生强辐射热、火 花或火焰的生产,2,利用气体、液体、固体作为燃料或将气体、液体进行燃烧作其他用的各 种生产,3,常温下使用或加工难燃物质的生产,4.,难燃烧物品,(,仓库,),戊类,常温下使用或加工非燃烧物质的生产,.,医院、商场、旅馆、学校、展览、剧院等 住宅、办公楼等非燃烧物品,(,仓库,),闪点,Flash point,在规定的试验条件下,液体挥发的蒸气与空气形成的混合物,遇火源能够闪燃的液体最低温度(采,用闭杯法测定)。,爆炸下限,Lower explosion limit,可燃的蒸气、气体或粉尘与空气组成的混合物,遇火源即能发生爆炸的最低浓度(可燃蒸气、气,体的浓度,按体积比计算)。,如何计算安全出口数量?,根据楼层,出口的净宽,楼层面积以及人数计算所得,问题:工厂,/,仓库属于哪一类火灾危险性?,Question:Which fire risk rating does my factory/warehouse belong to?,类别,使用,/,生产,/,储存物品示例,甲类,1.,己烷,戊烷,环戊烷,石脑油,二硫化碳,苯、甲苯,甲醇、乙醇,乙醚,蚁酸甲脂、醋酸甲脂、硝酸乙脂,汽油,丙酮,丙烯,,60,度及以上的白酒,2.,乙炔,氢,甲烷,环氧乙烷,水煤气,液化石油气,乙烯、丙烯、丁二烯,硫化氢,氯乙烯,电石,碳化铝,3.,硝化棉,硝化纤维胶片,喷漆棉,火胶棉,赛璐珞棉,黄磷,4.,金属钾、钠、锂、钙、锶,氢化锂、氢化钠,四氢化锂铝,5.,氯酸钾、氯酸钠,过氧化钾、过氧化钠,硝酸铵,6.,赤磷,五硫化磷,三硫化,磷,乙类,1.,煤油,松节油,丁烯醇、异戊醇,丁醚,醋酸丁脂、硝酸戊脂,乙酰丙酮,环己胺,溶剂油,冰醋酸,樟脑油,蚁酸,2.,氨气、液氯,3.,硝酸铜,铬酸,亚硝酸钾,重铬酸钠,铬酸钾,硝酸,硝酸汞、硝酸钴,发烟硫酸,漂白粉,4.,硫磺,镁粉,铝粉,赛璐珞板(片),樟脑,萘,生松香,硝化纤维漆布,硝化纤维色片,5.,氧气,氟气,6.,漆布及其制品,油布及其制品,油纸及其制品,油绸及其制品,丙类,动物油,植物油,沥青,蜡,润滑油,机油,重油,闪点的柴油、糠醛,度至度的白酒化学、人造纤维及其织物,纸张,棉、毛、丝、麻及其织物,谷物,面粉,天然橡胶及其制品,,竹、木,及其制品,中药材,电视机,收录机等电子产品,计算机房已录数据的磁盘,冷库中的鱼、肉,丁类,自熄性塑料及其制品,酚醛泡沫塑料及其制品,水泥刨花板,戊类,钢材,铝材,玻璃及其制品,陶瓷制品,搪瓷制品,不燃气体,玻璃棉,硅酸铝纤维,矿棉,岩棉,陶磁棉,,石膏及,其无纸制品,水泥,石,膨胀珍珠岩,问题:火灾危险性厂房,/,仓库举例,Question:Enumeration of plant/warehouse fire risk rating,问题:如何设置安全出口?,Question:How to set up safety exit?,厂房,/,仓库的安全出口应分散布置。每个防火分区,一个防火分区的每个楼层,其,相邻,2,个安全出口最近边缘之间的水平距离不应小于,5m,5m,问题:如何设置安全出口?,Question:How to set up safety exit?,沃尔玛要求:,设置在建筑楼层的两端;并且与之相连的通道相互独立。,问题;如何设置安全出口?,Question:How to set up safety exit?,房内任一点到最近安全出口的距离不应大于下表的规定(,m,)。,生产类别,耐火等级,单层厂房,多层厂房,高层厂房,地下、半地下厂房或厂房的地下室、半地下室,甲,一、二级,30.0,25.0,乙,一、二级,75.0,50.0,30.0,丙,一、二级三,级,80.060.0,60.040.0,40.0,30.0,丁,一、二级三,级四,级,不限,60.050.0,不限,50.0,50.0,45.0,戊,一、二级三,级四,级,不限,100.060.0,不限,75.0,75.0,60.0,问题:工厂需使用室外楼梯作为第二出口有哪些要求?,Question:Whats the requirement for outdoor stairs setting as the 2,nd,exit?,室外楼梯可替代封闭楼梯间或防烟楼梯间:,1,栏杆扶手的高度不应小于,1.1m,,楼梯的净宽度,不应小于,0.9m,;,2,倾斜角度不应大于,45,;,3,楼梯段和平台均应采取不燃材料制作,;,4,通向室外楼梯的门宜采用乙级防火门,,并应向室外开启;门开启时,不得减少楼梯,平台的有效宽度;,5,除疏散门外,楼梯周围,2.0m,内的墙面上不,应设置门窗洞口。疏散门不应正对楼梯段。,问题:自动扶梯和消防电梯可以算做安全出口吗?,Question:Can escalator and fire evaluator be considered as safety exit?,问题;连接两座厂房的天桥或廊桥可以视为安全出口?,Question:Can the corridor connect two facilities be considered as safety exit?,1.,天桥、跨越房屋的栈桥,供输送可燃气体和甲、乙、丙类液,体及可燃材料的栈桥,均应采用不燃烧体。,2.,输送有火灾、爆炸危险物质的栈桥不应兼作疏散通道。,3.,封闭天桥、栈桥与建筑物连接处的门洞以及敷设甲、乙、丙类液体,管道的封闭管沟(廊),均宜设置防止火势蔓延的保护设施。,4.,连接两座建筑物的天桥,当天桥采用不燃烧体且通向天桥的出口,符合安全出口的设置要求时,该出口可作为建筑物的安全出口。,问题:生产车间,/,仓库,办公室,宿舍可以设置在一起吗,?,安全出口如何设置?,Question:Can factory set plants&warehouse&dormitories in the same building?If,so how to set safety exit?,厂房,/,生产车间内严禁设置员工宿舍。,办公室、休息室等不应设置在甲、乙类长房内,生产车间设置仓库,生产车间和仓库中设置办公室,必须使用防火墙和防火门分隔。,并应,至少设置,1,个独立的安全出口,Fire escape routes must lead to safe assembly points without any obstructions.Assembly points must be designated and marked as such and must be kept clear at all times.,火灾逃生路线必须无障碍地通向安全的集合地点。集合地点必须被指定并标明是此用途,且必须不得占用。,挑选合适的集合地点并做标识,Proper access for fire department vehicles and other firefighting,equipment in the factory premises.,应为消防车和消防器材进出工厂留出通路。,问题;哪些工厂需要设置消防通道?,Question:What type of facility must have fire passage?,下列工厂、仓库区应设置消防车道:,占地面积大于,3000m2,的甲、乙、丙类厂房或占地面积大于,1500m2,的乙、丙类,仓库,应设置环形消防车道,确有困难时,应沿建筑物的两个长边设置消防车道。,供消防车取水的天然水源和消防水池。,可燃材料露天堆场区,占地面积大于,30000m2,的可燃材料堆场,液化石油气,储罐区,甲、乙、丙类液体储罐区和可燃气体储罐区,以及这些区内的环形,消防车道之间,储量大于规定的堆场、储存区,宜设置环形消防车道,如棉、麻、毛、化纤大于,1000(t),问题:消防车道的设置要求?,净宽度和净空高度均不应小于,4.0m,。坡度不宜,大于,转弯处应满足消防车转弯半径的要求,,供消防车停留的空地,其坡度不宜大于,3%,。,消防车道与厂房(仓库)、民用建筑之间不应,设置妨碍消防车作业的障碍物。,环形消防车道至少应有两处与其它车道连通。,尽头式消防车道应设置回车道或回车场,回车,场的面积不应小于,12.0m12.0m,;供大型消防,车使用时,不宜小于,18.0m18.0m,。,路面、扑救作业场地及其下面的管道和暗沟等,,应能承受大型消防车的压力。,可利用交通道路,但应满足消防车通行与停靠的要求。,不宜与铁路正线平交。如必须平交,应设置备用车道,,且两车道之间的间距不应小于一列火车的长度。,Adequate water supply for sprinkler and fire hydrant systems.,应有足够的水源供喷淋和消防栓使用。,问题:工厂应该安装自动喷水灭火系统吗?,下列场所应设置自动灭火系统,除不宜用水保护或灭火者以及本规范另有规定者外:,大于等于,50000,纱锭的棉纺厂的开包、清花车间;,大于等于,5000,锭的麻纺厂的分级、梳麻车间;,泡沫塑料厂的预发、成型、切片、压花部位;,占地面积大于,1500m2,的木器厂房;,占地面积大于,1500m2,或总建筑面积大于,3000m2,的单层、多层制鞋、,制衣、玩具及电子等厂房;,高层丙类厂房;建筑面积大于,500m2,的丙类地下厂房;,2,每座占地面积大于,1000m2,的棉、毛、丝、麻、化纤、毛皮及其制品的仓库;,建筑面积大于,500m2,的可燃物品地下仓库;,可燃、难燃物品的高架仓库和高层仓库(冷库除外);,问题;哪些工厂需要设置室内,/,室外消防栓?,厂房(仓库)堆场应设室外消防栓。,建筑占地面积大于,300m2,的厂房(仓库);物资储存集中的仓库;建筑内局,部危险性较大的区域;应设置,DN65,室内消防栓,下列建筑可不设室内消防栓:,耐火等级为一、二级且可燃物较少的单层、多层丁、戊类厂房(仓库),,耐火等级为三、四级且建筑体积小于等于,3000m3,的丁类厂房和建筑体积,小于等于,5000m3,的戊类厂房(仓库),存有与水接触能引起燃烧爆炸的物品的建筑物,室外消防栓的作用:,火灾时供消防车使用,其最大保护半径为,150m,,根据压力不同分为:高压临时高压低压。,室内消火栓的作用:,建筑内人员发现火灾采用灭火器无法控制初期火灾时的有效灭火设备,但一般需要专业人员或受过训练的人员才能较好地使用和发挥作用。同时,室内消火栓也是消防人员进入建筑扑救火灾的必需设备,问题:如何维护消火栓?,外观检查:有无生锈;接口垫圈是否完整无缺,,卷盘,/,水枪,/,水带是否损坏,阀门,/,卷盘转到是否灵活;,启泵按钮是否完整等;,定期进行排水检查,测试水压等;,每次检查数量不少于总数量的,25%,;没,12,个月累,计对每个消火栓检查,4,次,卷盘、水炮检查不少于一次;,选择消防给水系统最不利点消火栓出水。,消防栓的测试方法,:,手动启泵,就是直接按消火栓箱里的启泵按钮,一般设计时最顶上应该有个试验用的消火栓,需压力表的,压力值要做,0.15MPa0.2MPa.,如果没有设计这个,就找个离泵最远最高的消火栓,看喷多远,一般充实水柱长,10m,以上没问题,.,小于,7m,不行,斜,45,度喷,问题:工厂应使用哪种消防水源?,1,消防用水可由城市给水管网、天然水源或消防水池供给。,2,利用天然水源时,其保证率不应小于,97%,,且应设置可靠的取水设施。,3,符合下列规定之一的,应设置消防水池:,当生产、生活用水量达到最大时,市政给水管道、进水管或天然水源不能,满足室内外消防用水量;,市政给水管道为枝状或有,1,条进水管,且室内外消防用水量之和大于,25L/s,。,4,耐火等级不低于二级,且建筑物体积小于等于,3000m3,的戊类厂房或居住区人数,不超过,500,人且建筑物层数不超过两层的居住区,可不设置消防给水。,消防用水量:,建筑的全部消防用水量应为其室内、外所有消防设备同时开启的用水量之和。,耐火等级:,是衡量建筑物耐火成都的分级标度,规定建筑物的耐火等级是建筑设计防火规范中规定的防火技术措施中的最基本措施之一。,Audible,visible and operable smoke alarms placed,appropriately throughout the building with at least the,minimum number required by law.,Audible and operable fire alarms that can be heard in all,parts of the building,that operate as one system amongst,all floors and areas of the building.,应该在建筑物范围内合适地方设置不少于法定要求数量的可听、,可视、可操作的烟雾报警器。,火灾报警器应在建筑物范围内任何位置都能被听到,且可在各,楼层和建筑物所有区域范围内可作为一个系统进行操作。,问题:需要安装自动报警系统的工厂?,一级保护自动报警系统,1,甲、乙类生产厂房;,2,甲、乙类物品库房;,3,占地面积或总建筑面积超过,1000m2,的丙类物品库房;,4,总建筑面积超过,1000m2,的地下丙、丁类生产车间及物品库房;,5,任一层建筑面积大于,1500m2,或总建筑面积大于,3000m2,的制鞋、制衣、玩具等厂房。,二级保护自动报警系统,1,丙类生产厂房;,2,建筑面积大于,50m2,,但不超过,1000m2,的丙类物品库房;,3,总建筑面积大于,50m2,,但不超过,1000m2,的地下丙、丁类厂房及库房。,火灾自动报警系统:,由火灾探测报警系统,消防联动控制系统,可燃气体探测报警系统和火灾监控系统等构成。,什么事一级二级保护?,火灾自动报警系统的保护对象应根据其使用性质、火灾危险性、疏散和扑救难度等分为特级、一级和二级,*,这点可以自选,但必须有报警铃,且整栋楼都得听见,问题,:,工厂按法律要求可以不安装自动报警系统,是否可以不安装火灾报警器?,不是!,火灾报警器是火灾自动报警系统的一部分,由感应传感器和电子扬声器组成,疏散通道上的防火卷帘两侧,应设置火灾探测器组及其报警装置,且两侧应设置,手动控制按钮;,丙类生产厂房、丙类物品库房,丙、丁类物品库房。,柴油发电机房布置在民用建筑内时应设置火灾报警器,*丙类及以上等级厂房一定要安装烟感器,工厂储存纸箱区域,车间内成品储存区,喷涂,/,烤漆车间和工段,感烟探测器适合安装的场所,消防器材之一的感烟探测器适合安装在哪些场所?很多人都不知道。下面就将感烟探测器适用的场所简单介绍下:,1,)饭店、旅馆、教学楼、办公楼的厅堂、卧室、办公室等;,2,)电子计算机房、通讯机房、电影或电视放映室等;,3,)楼梯、走道、电梯机房等;,4,)书库、档案库等;,5,)有电气火灾危险的场所。,补充:符合下列条件之一的场所,宜选择点型感温探测器,不宜选择感烟探测器:,1,)相对湿度经常大于,95%,;,2,)无烟火灾;,3,)有大量粉尘;,4,)在正常情况下有烟和蒸气滞留;,5,)厨房、锅炉房、发电机房、烘干车间等;,6,)吸烟室等;,7,)其它不宜安装感烟探测器的厅堂和公共场所。,按国家标准,GB 50116-92,要求,应每半年至少测试一次探测器,问题:如何选择火灾报警器?,火灾报警器,感烟探测器,感温探测器,感光探测器,可燃气体探测器,复合式火灾探测器,点型,点型,线型,线型,紫外火灾型,红外火灾型,离子式,光电式,电容式,半导体式,红外光束,减光式,定温式,差温式,差定温式,气敏半导体型,
展开阅读全文