19.03.20241Copyright OBO BETTERMANN 2010OBO外部防雷系统外部防雷系统19.03.20242Copyright OBO BETTERMANN 2010引下线墙电气线路RL未设置足够的电气绝缘距离RL电气设备立式避雷针外部防雷中的电气绝缘距离外部防雷中的电气绝缘距离19.03.20243Copyright OBO BETTERMANN 2010绝缘防雷绝缘防雷IsolatedGFK-material19.03.20244Copyright OBO BETTERMANN 2010The isolated lightning protection systems made external lightning protection conform to the IEC 62305 possible.The security distance“s”can be managedup to a distance of 750mm.Through the individual parts the system couldbe build up according to desire.isolatedlightningprotection19.03.20245Copyright OBO BETTERMANN 2010Type:101 3-ES-16Item No.:5408976Iso-Combi-Set for 3-angle mountingL=750mmH=1500mmisolatedlightningprotection19.03.20246Copyright OBO BETTERMANN 2010Type:101 VS-16Item No.:5408978Iso-Combi-Set for V-mountingL=750mmisolatedlightningprotection19.03.20247Copyright OBO BETTERMANN 2010Type:101 FS-16Item No.:5408980Iso-Combi-Set for crease-mountingL=750mmisolatedlightningprotection19.03.20248Copyright OBO BETTERMANN 2010Type:101 VRS-16Item No.:5408982Iso-Combi-Set for tube-V-mountingL=750mmisolatedlightningprotection19.03.20249Copyright OBO BETTERMANN 2010平行布设的引线,保护屋面的电气线路Product range insulating lightning protection-Additional with =16mm GFK-rod-connector-and mounting-material for 16mm GFK-rodsisolatedlightningprotection19.03.202410Copyright OBO BETTERMANN 2010OBOisCon-Systemisolated Conductor19.03.202411Copyright OBO BETTERMANN 2010ConstructionofisCon-conductor弱导电性 EVA,抗紫外线导电 VPE绝缘 VPE导电 VPE35 mm 铜芯VPE=交交联聚乙聚乙烯EVA=乙乙烯醋酸乙醋酸乙烯聚合物聚合物19.03.202412Copyright OBO BETTERMANN 2010PurposeoftheisolatedconductorOBOisCon引引下下线线用用于于外外部部防防雷雷系系统统中中,它它能能代代替替或或减减少少IEC62305-3中中所所要要求求的的电电气气绝绝缘缘距距离离.isCon提提供供相相当当于于0.75m空空气或气或1.5m混凝土的电气绝缘距离混凝土的电气绝缘距离.19.03.202413Copyright OBO BETTERMANN 2010IEC62305中电气绝缘距离计算公式中电气绝缘距离计算公式19.03.202414Copyright OBO BETTERMANN 2010公式中的参数说明protectionclasski(IEC-62305-3)I0,1II0,075IIIundIV0,05materialkmair1Concreate,stone0,5GFK-material(manufacturer)0,7isolatedlightningprotectionnumberofdownconductorkc11210,54andmore11/nki 雷区kc 引下线数量km 物质 19.03.202415Copyright OBO BETTERMANN 2010PlanningandinstallationisCon引下线可使用的长度可根据DIN EN 62 603确定:防雷保护区可使用isCon 引下线的最大长度I9,37 mII12,5 mIII+IV15.00 m s=0,75 m ki=0,05(LPS=3)kc=1(1根引下线)km=1(空气)l=引下线的使用长度 0.0515.019.03.202416Copyright OBO BETTERMANN 2010GB50057中对绝缘距离的要求条纹中对绝缘距离的要求条纹 3.2.5条 独立避雷针和架空避雷线独立避雷针和架空避雷线(网网)的支柱及其接地装置至被保护建筑物的支柱及其接地装置至被保护建筑物及与其有联系的管道、电缆等金属物之间的距离及与其有联系的管道、电缆等金属物之间的距离(图图3.2.1),应符合下列表达,应符合下列表达式的要求,但不得小于式的要求,但不得小于3m:防雷装置至被保护物的距离 1、地上部分:当hx5Ri时,Sa10.4(Ri+0.1hx)当hx5Ri时,Sa10.1(Ri+hx)式中 Sa1空气中距离(m);Se1地中距离(m);Ri独立避雷针或架空避雷线(网)支柱处接地装置的冲击接地电阻();Hx被保护物或计算点的高度(m)。19.03.202417Copyright OBO BETTERMANN 2010对比对比使用使用OBOisCon引下线引下线没有设置电气绝缘距离没有设置电气绝缘距离wall电气装置金属引下线传统方法设置电气绝缘距离传统方法设置电气绝缘距离(空气)(空气)wall金属引下线OBOisCon引下线walls电气装置电气装置19.03.202418Copyright OBO BETTERMANN 2010Purposeoftheisolatedconductor传统方法绝缘距离传统方法绝缘距离使用使用OBOisCon线实现绝缘距离线实现绝缘距离s19.03.202419Copyright OBO BETTERMANN 2010应用例子:通信基站卫星天线太阳能电池Applications19.03.202420Copyright OBO BETTERMANN 2010在Darmstadt实验室中的测试 19.03.202421Copyright OBO BETTERMANN 2010isCon引下线电气绝缘距离测试(空气)引下线电气绝缘距离测试(空气)Marx-GeneratorExamineeCT*Cut off spark gap*泻放控制回路0,75m19.03.202422Copyright OBO BETTERMANN 2010isCon引下线引下线电气绝缘距离测试(固体)电气绝缘距离测试(固体)Marx-Generator1,5mCut off spark gapExamineeCT*泻放控制回路19.03.202423Copyright OBO BETTERMANN 2010关于isCon引下线铜芯的形式几截面积的要求:关于铜芯的直径要求关于铜芯的直径要求VDE0185-305-3(IEC62305-3)19.03.202424Copyright OBO BETTERMANN 2010FunctionofisCon-conductor1,5mLightning currentSeveral kA位移电流,a few mA19.03.202425Copyright OBO BETTERMANN 2010S1,5m1,5m19.03.20242519.03.202426Copyright OBO BETTERMANN 2010S1,5m19.03.20242619.03.202427Copyright OBO BETTERMANN 2010S1,5m0,6m1,6m19.03.202427min.6mmForpotentialcontrol19.03.202428Copyright OBO BETTERMANN 2010s19.03.202429Copyright OBO BETTERMANN 2010potentialconnectionxPA-clamp distance(x)Separation distance(s)如果经计算后安全距离要求小于750mm,可减短PA连接件与外壳接地端子之间的距离.If the calculated separation distance(s)is below than 75 cm,you can reduce the distance between PA-clamp and connecting element(x).19.03.202430Copyright OBO BETTERMANN 2010传统绝缘做法传统绝缘做法使用使用isCon超绝缘引下线超绝缘引下线s新产品商业应用推介:新产品商业应用推介:isCon超绝缘引下线系统超绝缘引下线系统电气绝缘做法比较电气绝缘做法比较1.有效保护外部重要有效保护外部重要设备设备及及人身人身安全安全!2.释放天面空间释放天面空间!3.专用切割工具,快速切割专用切割工具,快速切割,全现场制作全现场制作!4.多种的连接备件,安装无须焊接,多种的连接备件,安装无须焊接,适用适用危险场所安装危险场所安装!19.03.202431Copyright OBO BETTERMANN 20104.新产品商业应用推介:新产品商业应用推介:isCon超绝缘超绝缘4.5站立模式站立模式全模块化设计全模块化设计,快速安装快速安装配备专用切割钳配备专用切割钳商业应用推介:商业应用推介:isCon超绝缘引下线系统超绝缘引下线系统19.03.202432Copyright OBO BETTERMANN 2010isCon重要商业价值重要商业价值-人身安全的保护人身安全的保护isCon绝缘引下线 普通金属引下线 钢结构厂房尤其危险19.03.202433Copyright OBO BETTERMANN 2010isCon重要商业价值重要商业价值-人身安全的保护人身安全的保护ProtectionmeasuresagainsttouchvoltagesaccordingtoVDE0185-305-3(IEC62305-3)在某一些情况下,即使建筑物的外部绝缘防雷设施已经按照规范实施,但在引下线的附近,也会出现的危险触电隐患这些安全隐患可采取以下措施减少:a)人很少接近;或者人出现在引下线或者与引下线相关结构附近的时间非常短b)在引下线周围米内的土壤,其土壤电阻率不小于19.03.202434Copyright OBO BETTERMANN 2010VDE0185-305-3(IEC62305-3)中防止因接触引下线而发生触电中防止因接触引下线而发生触电危险的措施危险的措施如果这些条件都不满足,应采取以下保护措施,防止人身触电危险:出露下导线绝缘材料需要能承受一个100千伏,1,2/50s的冲击耐受电压,例如:至少3毫米交联聚乙烯;OBOisCon引下线符合这条规定引下线符合这条规定采用网格接地终端装置实现等电位化;设置栏杆或警告标志,将人接触到引下线的可能性减到最低19.03.202435Copyright OBO BETTERMANN 2010isCon线制作步骤线制作步骤1.2.3.4.5.6.25mm19.03.202436Copyright OBO BETTERMANN 2010isCon线接头制作线接头制作7.8.9.10.11.12.19.03.202437Copyright OBO BETTERMANN 2010快速组合快速组合thread-ed rodArt.:5408971(L=270mm)Art.:5408972(L=340mm)Art.:5408973(L=430mm)Fang-Fix concrete blocksArt.:5403227FangFix edge protectionArt.:540323519.03.202438Copyright OBO BETTERMANN 2010-站立式快速安装站立式快速安装19.03.202439Copyright OBO BETTERMANN 2010整体解决方案整体解决方案Connection elementCable bracketsPotential connectionCable bracket VA/PARoof cable holder VA/PAInsulated interception rodElements for wall mountingInterception rod stand19.03.20243919.03.202440Copyright OBO BETTERMANN 2010Notes!OBO的isCon 系统是匹配元件的范围。在安装,请使用仅OBO的产品范围部件,否则就不能保证安全的安装可能.确保电缆不受玷污.isCon 电缆护套不得切断或损坏.isCon 电缆护套不得描绘了不同的颜色。如果你希望有一个不同颜色的变种,请与您的OBO的接触联系.OBO的isCon 电缆不允许在地下布设.19.03.202441Copyright OBO BETTERMANN 2010Thankyou!
展开阅读全文