收藏 分销(赏)

小区超市框架结构计算书.doc

上传人:二*** 文档编号:4680969 上传时间:2024-10-09 格式:DOC 页数:55 大小:8.23MB 下载积分:5 金币
下载 相关 举报
小区超市框架结构计算书.doc_第1页
第1页 / 共55页
本文档共55页,全文阅读请下载到手机保存,查看更方便
资源描述
摘 要 本建筑为金光小区超市,为4层框架结构,各层层高4.5米,建筑总高19.70米。总建筑面积7000.5平方米。本建筑从平面布局的合理性,到工作人员、购物者和货物的分流,到采光、通风及保温的设计,都充分体现了以人为本的设计理念。本建筑采用框架双向承重,结构计算考虑了风荷载及抗震要求,考虑结构塑性内力重分布的有利影响,对竖向荷载作用下的内力进行调幅,分别考虑恒载和活载由可变荷载效应控制的组合和由永久荷载效应控制的组合。 关键词:超市 框架结构 抗震设计 ABSTRACT This building is supeimaket of jinguang, and frame of 4 storeys structure, bed building store height 4.5 meters, construction overall height 19.70meters.With the whole construction area of 7000.5 square meters.This building is from the rationality of the plane figure, to the distributary of staff member, buyer and books, get daylighting, ventilate and design that keep warm, fully reflect the design idea of People First. This building adopt the two-way bearing of frame. This building of structure has calculated and considered the wind loads and antidetonation is required, consider structure plasticity favorable influence that internal force distribute again, load to verticality internal force of function carry on amplitude modulation, consider permanent year and live by variable to load the association that the effect controls and loaded the association that the effect controlled for ever year separately. Key word: Supermaket Frame Structure Antidetonation 目 录 第1章 设计资料 1 第2章 结构选型及结构布置 2 第3章 框架(KJ-4)截面尺寸估计算简图 梁柱线刚度 3 3.1 框架截面尺寸估算 3 3.2 确定框架计算简图 3 3.3 框架梁柱的线刚度计算 4 第4章 荷载计算 5 4.1 恒荷载标准值计算 5 4.2 活荷载标准值计算 6 第5章 框架荷载计算 7 5.1 竖向荷载作用 7 5.2 水平荷载作用 9 第6章 风载作用下的位移验算 14 6.1 侧移刚度 14 6.2 框架侧移验算 14 第7章 内力计算 16 7.1 竖向荷载作用下内力计算 16 7.2 水平荷载作用下内力计算 16 第8章 内力组合 26 8.1 构件的截面 26 8.2 构件的弯矩调幅 26 8.3 构件的内力组合 26 第9章 截面设计与配筋计算 32 9.1 设计依据 32 9.2 框架柱截面设计 32 9.3 框架梁截面设计 37 9.4 楼板的设计 40 第10章 基础设计 42 10.1基础底面尺寸的确定 42 10.2基底净反力设计值计算基底净反力设计值 42 10.3配筋计算 43 10.4基础的配筋图 45 第11章 梁式楼梯设计 46 11.1踏步板设计 46 11.2斜梁设计 47 11.3平台板设计 48 11.4平台梁设计 49 致 谢 51 参 考 资 料 52 第1章 设计资料 1.1 工程名称:金光小区超市(7000.5m2) 1.2 工程概况: 建筑总高度为19.70M,共四层,每层层高4.5M,室内外高差为0.6M。具体情况可参见结构平面图。 1.3 温 度: 最热月平均29.6℃, 最冷月平均4.2℃,夏季极端最高39.8℃,冬季极端最低-9.5℃。 1.4 相对湿度: 最热月平均73%。 1.5主导风向: 全年为西北风,夏季为东南风,基本风压为w0=0.55KN/M。 1.6 雨雪条件: 年降雨量1450mm, 日最大降水强度192mm/日,暴雨降水强度3.31/s*100m3,最大积雪深80mm,基本雪压s0=0.3kN/m2。 1.7 工程地质条件 ⑴自然地表0.8m以内为杂填土,(地基承载力特征值fak=100KN/m2),填土下层为4.4m粘土,(地基承载力特征值fak=200KN/m2),其下为中密细砂,(地基承载力特征值fak=270KN/m2)。 ⑵地下水位在地表1.5m以下,无侵蚀性,场地为Ⅱ类。 ⑶根据《建筑抗震设计规范》(GB5001-2001)附录A查得本工程抗震设防烈度为7度,地震分组第一组。 1.8 材料选用: ⑴砼:采用C30 ⑵钢筋:纵向受力钢筋采用HRB400(fy=fy‘=360N/mm2)和HRB335(fy=fy‘=300N/mm2),其余采用热轧钢筋HPB235(fy=fy=210N/mm2)。 ⑶墙体:外墙采用灰砂砖,其尺寸为240mm*120mm*60mm,r=18kN/m2。 ⑷窗:铝合金玻璃窗r=0.35kN/m。 ⑸门:木门r=0.2kN/m。 第2章 结构选型及结构布置 2.1 结构体系选型: 采用钢筋混凝土现浇框架结构(纵横向承重框架)体系。 2.2 屋面结构:采用钢筋混凝土肋形屋盖,屋面板厚120mm。 2.3 楼面结构: 全部采用现浇钢筋混凝土肋形楼盖,楼面板厚120mm。 2.4 楼梯结构: 采用钢筋混凝土梁式楼梯。(梯段水平方向跨度>3m) 2.5 天沟: 采用现浇天沟。 2.6 电梯间: 采用砖砌体每边加设圈梁。 2.7 过梁:窗过梁以及带雨篷的门过梁均采用钢筋混凝土梁,并采用纵向框架兼作窗过梁。 2.8 基础梁:采用现浇钢筋混凝土基础梁。 2.9 基础:地基承载力较大,采用钢筋混凝土柱下单独基础。 2.10 结构布置:详见各层结构平面布置图、屋面结构平面布置图、基础平面图及框架结构布置图。 第3章框架(KJ-4)截面尺寸估计算简图 梁柱线刚度 3.1 框架截面尺寸估算 3.1.1框架梁截面尺寸: 主梁: hb=(1/8~1/18)l0=(1/8~1/18)*7200 =900~400mm 取600mm bb=(1/2~1/4)hb =(1/2~1/4)*600 =300~150mm 取300mm 次梁: hb=l/18=7200/18=400mm 取500mm bc =250mm 3.1.2框架柱截面尺寸: bc=(1/12~1/18)Hi=(1/12~1/18)*5700 =475~317mm 取600mm hc=(1-2)bc=600mm 取600mm 3.2 确定框架计算简图 选取一榀横向框架KJ-④为计算单元,计算单元如图所示。 图3-1 板传荷示意图 假定框架柱嵌固于基础顶面。由于各层柱的截面尺寸不变,故梁跨等于柱截面形心轴线之间的距离。底层柱高从基础顶面算至二层楼面,基顶标高根据室内外高差为-1.2,二层楼面标高为4.5m,故底层标高为5.7m,其余各层柱标高从楼面算至上一层楼面,层高为4.5m. 3.3 框架梁柱的线刚度计算 3.3.1对中框架梁取I=2I0 i左边梁=EI/L=3.0*107KN/M2*2*1/12*0.3M*(0.6M)2/7.2M=4.5*104KN.M i中跨梁=EI/L=3.0*107KN/M2*2*1/12*0.3M*(0.6M)2/7.2M=4.5*104KN.M i右边梁=EI/L=3.0*107KN/M2*2*1/12*0.3M*(0.6M)2/7.2M=4.5*104KN.M 3.3.2底层柱(A-E轴) i底柱=EI/L=3.0*107KN/M2*1/12(0.6M)2/5.7M=5.7*104KN.M 其余各层柱(A-F轴) i余柱=EI/L=3.0*107KN/M2*1/12(0.6M)2 /4.5M=7.2*104KN.M 3.3.3令余柱i余柱=1.0,其余各杆件的相对线刚度为: i’左边梁=4.5*104KN.M/7.2*104KN.M=0.63 i’中跨梁=4.5*104KN.M/7.2*104KN.M=0.63 i’右边梁=4.5*104KN.M/7.2*104KN.M=0.63 i’底柱=5.7*104KN.M/7.2*104KN.M=0.79 框架梁柱相对线刚度如图所示.作为计算各节点杆端弯矩分配系数的依据. 图3-2 计算简图 第4章 荷载计算 4.1 恒荷载标准值计算 ⑴屋面 (做法选用中南标98ZJ001屋5:上人隔热保温Ⅱ级屋面) 总厚度:251mm 自重: 3.35KN/M2 结构层:120mm现浇钢筋砼板 0.12M*25KN/M3=3KN/M2 抹灰层:12mm厚水泥砂浆 0.012M*20KB/M2=0.24KN/M2 合计 6.59KN/M2 ⑵楼面 (做法选用中南标98ZJ001楼6) 10mm面层 水磨石地面 : 20mm水泥砂浆打底 0.65KN/M2 素水泥浆结合层一道 结构层:120厚现浇钢筋混凝土板 0.12M*25KN/M3=3KN/M2 抹灰层:12厚水泥砂浆 0.012M*20KN/M3=0.24KN/M2 合计 3.89KN/M2 ⑶梁自重 ⑶-1、主梁 b*h=300mm*600mm 梁自重: 25KN/M3*0.3M*(0.6M-0.12M)=3.60KN/M 抹灰层:12厚水泥砂浆 20KN/M3*0.012M*[(0.6M-0.12M)*2+0.3M ]=0.35KN/M 合计 3.95KN/M ⑶-2、次梁 b*h=250mm*500mm 梁自重: 25KN/M3*0.25M*(0.5M-0.12M)=2.38KN/M 抹灰层: 20KN/M3*0.012M*[(0.5m-0.12m)*2+0.25M ]=0.24KN/M 合计 2.62KN/M ⑶-3、基础梁 b*h=250mm*400mm 梁自重: 25KN/M3*0.25M*0.4M=2.5KN/M ⑷柱自重 b*h=600mm*600mm 柱自重: 25KN/M3*0.6M*0.5M=9KN/M 抹灰层: 20KN/M3*0.012M*0.5M*4=0.48KN/M 合计 9.48KN/M ⑸ A轴外纵墙自重 ⑸-1、标准层 纵墙: 0.9*0.24M*18KN/M=3.89KN/M 铝合金窗: 3.0M*0.35KN/M2=1.05KN/M 20 厚混合砂浆内墙面: 0.02M*17KN/M3*(4.5M-3.0M)=0.51KN/M 20厚水泥砂浆外墙漆: (4.5M-3.0M)*0.02M*20KN/M3=0.6KN/M 合计: 3.05KN/M ⑸-2、底层 纵墙: (5.7M-0.7M-0.4M-3.0M)*0.24M*18KN/M3=6.91KN/M 铝合金窗: 3.0M*0.35KN/M2=1.05KN/M 20厚混合砂浆内墙面: (4.5M-3.0M)*0.02M*17KN/M3=0.51KN/M 20厚水泥砂浆外墙漆: (4.5M-3.0M)*0.02M**20KN/M3=0.60KN/M 合计: 9.07KN/M ⑹ E轴外纵墙自重 ⑹-1、标准层 纵墙: 0.9*0.24M*18KN/M=3.89KN/M 铝合金窗: 3.0M*0.35KN/M2=1.05KN/M 20 厚混合砂浆内墙面: 0.02M*17KN/M3*(4.5M-3.0M)=0.51KN/M 20厚水泥砂浆外墙漆: (4.5M-3.0M)*0.02M*20KN/M3=0.6KN/M 合计: 6.05KN/M ⑹-2、底层 纵墙: (5.7M-0.7M-0.4M-3.4M)*0.24M*18KN/M3=5.18KN/M 铝合金窗: 3.4M*0.35KN/M2=1.19KN/M 20厚混合砂浆内墙面: (4.5M-3.4M)*0.02M*17KN/M3=0.37KN/M 20厚水泥砂浆外墙漆: (4.5M-3.0M)*0.02M**20KN/M3=0.44KN/M 合计: 7.18KN/M 4.2活荷载标准值计算 ⑴屋面和楼面活荷载计算 上人屋面:2.0KN/M2 楼面:3.5KN/M2 ⑵雪荷载 Sk=1.0*3.0KN/M2=0.3KN/M2 屋面活荷载与雪荷载不同时考虑,两者中取大值即2.0KN/M。 第5章 框架荷载计算 5.1竖向荷载作用 5.1.1框架梁横向导荷荷载 ⑴A-B轴间框架梁 ① 屋面板传荷载 板传至梁上的荷载等效为均布荷载,荷载的传递如图3-1所示。 恒载:6.59KN/M2*1.8M*(1-2*0.252+0.253)*2=21.12KN/M 活载:2.0KN/M2*1.8M*(1-2*0.252+0.253)*2=6.41KN/M ② 楼面板传荷载 恒载:3.89KN/M2*1.8M*(1-2*0.252+0.253)*2 =12.46KN/M 活载:3.5KN/M2*1.8M* (1-2*0.252+0.253)*2 =11.22KN/M ③ 梁自重:3.95KN/M ④ A-B轴间框架梁等效均布荷载为: 屋面梁:恒载=梁自重+板传荷载    =3.95KN/M+21.12/M=25.07KN/M   活载=板传荷载=6.41KN/M 楼面梁:恒载=梁自重+板传荷载   =3.95KN/M+12.46KN/M=16.41KN/M   活载=板传荷载=11.22KN/M ⑵B-C轴间框架梁 C-D轴间框架梁 D-E轴间框架梁 B-C轴间框架梁、C-D轴间框架梁和D-E轴间框架梁,其受荷方式均与A-B轴框架梁一致,因此,屋面梁、楼面梁的均布荷载与A-B轴框架梁相同。 5.1.2框架梁纵向导荷荷载 ① A轴柱纵向集中荷载的计算 顶层柱 女儿墙自重:(做法:墙高1100mm,100砼压顶) 0.24M*1.1M*18KN/M3+25KN/M3*0.24M*0.10M+20KN/M3*0.02KN/M2*1.1M =5.79KN/M 恒载 =女儿墙自重+主梁自重+板传荷载+次梁传荷载 =5.79KN/M*7.2M+3.95KN/M*(7.2M-0.6M)+6.59KN/M2*1.8M*(5/8)* 2*3.6M+6.59KN/M2*1.8M*(1-2*0.252+0.253)*7.2M/(2*2)*2+(2.62KN/M*7.2M/4)*2 =169.04KN 活载=板传次梁活载=2.0KN/M2*1.8M*(5/8)*3.6*2+2.0KN/M2*1.8M*(1-2*0.252+0.253)* 7.2M*2/4 =27.73KN 标准层柱 恒载=梁自重+板传荷载+墙自重 =3.95KN/M*(7.2M-0.6M)+3.89KN/M2*1.8M*(5/8)*2*3.6M+3.89 KN/M2*1.8M*(1-2*0.252+0.253)*7.2M*2/4+2.62KN/M*7.2M/2 =130.44KN 活载=板传活载 =3.5KN/M2*1.8M*(5/8)*2*3.6M+3.5KN/M2*1.8M*(1-2*0.252+0.253)*7.2M*2/4 =48.54KN 基础顶面恒载=底层外纵墙自重+基础梁自重 =9.07KN/M2*(7.2M-0.6M)+2.5KN/M*(7.2M-0.6M)=77.52KN ② B轴柱纵向集中荷载 顶层柱 恒载=主梁自重+板传次梁恒载+墙自重=3.95KN/M*(7.2M-0.6M)+6.59KN/M2*1.8M*(5/8)*3.6M*2*2+6.5 9KN/M2*1.8M*(1-2*0.252+0.253)*7.2M/(2*2)*4+2.62KN/M*7.2M/4*4 =152.24KN 活载=板传次梁活载 =2.0KN/M2*1.8M*(5/8)*3.6M*4+2.0KN/M2*1.8M*(1-2*0.252+0.253)* 7.2M/4*4 =55.47KN 标准层柱 恒载=主梁自重+板传次梁恒载+墙自重 =3.95KN/M*(7.2M-0.5M)+3.89KN/M*1.8M*(5/8)*3.6M*4+3.89 *1.8M* (1-2*0.252+0.253)*7.2M/4*4+2.62*7.2M/4*4 =152.24KN 活载=板传次梁活载 =3.5KN/M2*1.8M*(5/8)*3.6*4+3.5KN/M2*1.8M*(1-2*0.252+0.253)7.2M/4*4 =97.07KN 基础顶面恒载=基础梁自重 =2.5KN/M*(7.2M-0.5M)=16.75KN ③ 其余轴柱纵向集中荷载 C、D轴纵向集中荷载与B轴纵向集中荷载相同; E轴纵向集中荷载与A轴纵向集中荷载相同; 框架在竖向荷载作用下的受荷总图如下所示(图中数值为标准值)。 图5-1 竖向受荷总图 5.2、水平荷载作用 5.2.1 风荷载计算 集中风荷载标准值计算 作用在屋面梁和楼面梁节点处的集中风荷载标准值: 式中基本风压为0.55KN/M2; z --风压高度变化系数,因建设地点位于市区故地面粗糙度为C类。查《混凝土结构设计》附表5.1; s --风荷载体型系数,根据建筑物体型查得=1.3; z --风振系数,对于高度不大于30m或高宽比小于1.5的房屋结构,取=1.0 hi—下层柱高; hj—上层柱高;对顶层为女儿墙高度的2倍; B-- 迎风面的宽度,B=7.2M; 集中风荷载标准值 表5-1 离地 高度 Z/M z z s W0(KN/M) Hi/M Hj/M Wk/KN 18.6 0.81 1.0 1.3 0.55 4.5 2.4 14.39 14.1 0.74 1.0 1.3 0.55 4.5 4.5 17.14 9.6 0.74 1.0 1.3 0.55 4.8 4.5 17.14 5.1 0.74 1.0 1.3 0.55 5.1 4.5 18.29 5.2.1 水平地震作用计算 根据《建筑抗震设计规范》(GB5001-2001)查阅:本工程抗震设防烈度为7度,地震分组为第一组,设计基本地震加速度为0.10g。因属2类场地,建筑结构的特征周期为0.35s,根据建筑使用功能的重要性,超市建筑为丙类建筑。 ⑴抗震计算单元及动力计算简图 结构抗震分析时一般取整个房屋或抗震缝区段为计算单元,动力计算简图为串联多自由度体系。 对于本工程建筑物平、立面布置的形状规则,结构构件布置质量与刚度变化均匀,为简化计算,取一榀框架计算单元内的重力荷载代表值。 ⑵一榀框架内,梁、柱、墙、窗、门重力荷载计算: 梁柱重力荷载标准值 表5-2 层次 构件 g KN/M ln 每层/n Gi KN KN 2~4 纵向主梁 3.95 3.43*2=6.86 5 135.49 348.39 横向主梁 3.95 6.6 4 104.28 次梁 2.62 6.9 8 144.62 柱子 9.48 4.5 5 213.30 1 纵向主梁 3.95 3.43*2=6.86 5 135.49 348.39 横向主梁 3.95 6.6 4 104.28 次梁 2.62 6.9 8 144.62 柱子 9.48 5.7 5 270.18 顶层屋面 女儿墙(A轴和E轴总和):5.49*7.5*2=83.38KN 屋面自重:6.59*7.2*(7.2*4+0.6)=1394.97KN 标准层楼面 楼面自重:3.89*7.2*(7.2*4+0.6)=823.44KN 标准层外纵墙(A和E轴总和):6.05*(7.2-0.6)*2=79.86KN 底层外纵墙自重(A和E轴总和): 9.07*(7.2-0.6)+7.18*(7.2-0.6)=107.25KN 活载:楼面 3.5KN/M2 雪荷载: 0.3KN/M2 ⑶ 该建筑物高度为19.20m,且质量和刚度沿高度均匀分布,故可以采用底部剪力法来计算。 作用于屋面梁及各层楼面梁处的重力荷载代表值为: 屋面梁处:GEW=结构和构件自重+50%雪荷载 楼面梁处:Gei=结构和构件自重+50%活荷载 其中结构和构件自重取楼面上、下1/2层高范围内(屋面梁处取顶层的一半)的结构及构件自重(包括纵横梁自重、楼板结构层及构造层、纵横墙体及柱等自重。 4层屋面梁处: GEW=结构和构件自重+50%雪荷载 =[384.39+213.30/2+83.38+1394.97+79.86/2]+0.5*0.3*7.2*(7.2*4+0.6) =2041.07KN 2—3层楼面梁处:Gei=结构和构件自重+50%活荷载 =[384.39+213.3/2*2+823.44+79.86]+0.5*3.5*7.2*29.4 =1871.43KN 1层楼面梁处: Gei=结构和构件自重+50%活荷载 =[384.39+213.2/2+270.18/2+823.44+79.86/2+107.25/2]+0.5*3.5* 7.2*29.4 =1919.57KN 各质点的重力荷载代表值及质点高度如图所示: 图5-2 一榀框架重力荷载代表值(4号轴线) ⑷框架自振周期的计算: T1=0.33+0.00069H2 式中H—房屋主体结构的高度(M),H=19.20M B—房屋振动方向的长度(M),在计算横向水平地震作用时,为房屋宽度28.8M; 对于横向振动: T1=0.33+0.00069*19.22=0.413s ⑸多遇水平地震作用标准值的计算: 由设防烈度为7度,场地土为Ⅱ类第一组,查《建筑抗震设计规范》(GB5001-2001)表3—2得:水平地震影响系数最大值=0.08,Tg=0.35S,则横向地震影响系数r=0.9 ===0.069 对于多质点体系,结构底部总横向水平地震作用标准值: ==(2041.07+1871.43*2+1919.57)*0.85*0.069=451.81KN =0.35s =0.413s<1.4=0.49s 故=0 横向Fieik的计算 表5-3 层 Gi (KN) Hi (M) GiHi Hi G1H1/(GjHj)Fek(1-) 4 2041.07 19.2 39188.54 96728.71 183.05 3 1817.43 14.7 27510.02 128.50 2 1817.43 10.2 19088.59 89.16 1 1919.57 5.7 10941.55 51.11 ⑹框架水平位移验算 横向2~4层D值的计算 表5-4 构件名称 /(KN/m) 边柱2根 =0.625 0.238 10155 中柱3根 0.385 16427 横向1层D值的计算 表5-5 构件名称 /(KN/m) 边柱 2根 =0.789 0.462 9726 中柱 3根 0.581 12232 横向地震作用下框架的侧移 表5-6 层次 Fi(KN) Vi(KN) i(KN/M) e(m) e/h 4 183.05 183.05 69591 0.0026 1/1731 3 128.50 311.55 69591 0.0045 1/1000 2 89.16 400.71 69591 0.0058 1/776 1 51.11 451.82 56448 0.0080 1/713 u= 侧移验算:层间侧移最大值:1/713<1/550(满足) 第6章 风载作用下的位移验算 6.1 侧移刚度 横向2-4层D值的计算 表6-1 构件名称 = = D=ic A轴柱 2*4.5*104/(2*7.2*104)=0.63 0.240 10240 B轴柱 2*(4.5*104+7.5*104)/(2*7.2*104)=1.25 0.385 16427 D轴柱 2*(4.5*104+7.5*104)/(2*7.2*104)=2.08 0.385 16427 E轴柱 2*(4.5*104+7.5*104)/(2*7.2*104)=2.08 0.385 16427 F轴柱 2*4.5*104/(2*7.2*104)=0.63 0.240 10240 横向底层D值的计算 表6-2 构件名称 = = D=ic A轴柱 4.5*104/5.7*104=0.79 0.462 9726 B轴柱 (4.5*104+4.5*104)/5.7*104 =1.58 0.581 12232 C轴柱 (4.5*104+4.5*104)/5.7*104 =1.58 0.581 12232 D轴柱 (4.5*104+4.5*104)/5.7*104 =1.58 0.581 12232 E轴柱 4.5*104/5.7*104=0.79 0.462 9726 6.2 框架侧移验算 水平荷载作用下框架的层间侧移可按下式计算: 框架在风荷载作用下侧移的计算 表6-3 层次 Wj/KN Vj/KN /(KN/M) /m /h 4 14.39 14.39 69761 0.0002 1/21815 3 17.14 31.53 69761 0.0005 1/9956 2 17.14 48.67 69761 0.0007 1/6450 1 18.29 66.96 56148 0.0012 1/3773 =0.0026m 侧移验算:层间侧移最大值1/3773<1/550 满足 第7章 内力计算 为简化计算,考虑如下几种单荷情况: ⑴ 恒载作用; ⑵ 活荷载作用于AB跨; ⑶ 活荷载作用于BC跨; ⑷ 活荷载作用于CD跨; ⑸ 活荷载作用于DE跨; ⑹ 风荷载作用(从左向右吹,或从右向左吹) ⑺ 水平地震作用(从左向右作用,或从右向左作用) 7.1 竖向荷载作用下内力计算 7.1.1 恒荷载标准值作用下的内力计算如图7-1 7-2 7-3 7.1.2 活荷载标准值作用下的内力计算如图7-4 7-5 7-6 7.2 水平荷载作用下内力计算 在水平荷载作用下手算的内力近似计算方法有:反弯点法、D值法、门架法等。本次设计采用D值法进行计算从左住右水平风荷载作用和水平地震作用(从左向右作用)下的内力(M、V、N)。 为简化计算,考虑水平荷载作用下几种情况及内力如下: ① 风荷载作用(从左向右吹) ② 风荷载作用(从右向左吹) ③ 水平地震作用(从左向右作用) ④ 水平地震作用(从右向左作用) 7.2.1 风荷载标准值作用下的内力计算:(D值法) D值法计算步骤: ⑴求各柱反弯点处的剪力; ⑵求各柱反弯点高度; ⑶求各柱的杆端弯矩及梁端弯矩; ⑷求各柱的轴力和梁剪力。 框架柱端剪力及弯矩分别按下式计算: 上式的y为按表3.6.3和表3.6.5(《砼结构设计》)修正后的值。 各层柱反弯点位置计算 表7-1 层号 层高 A轴柱y B轴柱y C轴柱y D轴柱y E轴柱y 4 4.5 0.30 0.36 0.36 0.36 0.30 3 4.5 0.40 0.45 0.45 0.45 0.40 2 4.5 0.43 0.44 0.44 0.44 0.43 1 5.7 0.64 0.57 0.57 0.57 0.64 风荷
展开阅读全文

开通  VIP会员、SVIP会员  优惠大
下载10份以上建议开通VIP会员
下载20份以上建议开通SVIP会员


开通VIP      成为共赢上传

当前位置:首页 > 环境建筑 > 其他

移动网页_全站_页脚广告1

关于我们      便捷服务       自信AI       AI导航        抽奖活动

©2010-2026 宁波自信网络信息技术有限公司  版权所有

客服电话:0574-28810668  投诉电话:18658249818

gongan.png浙公网安备33021202000488号   

icp.png浙ICP备2021020529号-1  |  浙B2-20240490  

关注我们 :微信公众号    抖音    微博    LOFTER 

客服