1、电机1类配合选型表序号电机功率(380V)额定电流(A)保护断路器10.55KW1.6C65D 3P 4A20.75KW2C65D 3P 4A31.1KW2.8C65D 3P 4A41.5KW3.7C65D 3P 6A52.2KW5.3C65D 3P 10A63KW7C65D 3P 12A74KW9C65D 3P 16A85.5KW12C65D 3P 20A97.5KW16C65D 3P 25A109KW18.1C65D 3P 25A1111KW23C65D 3P 32A1215KW30C65D 3P 40A1318.5KW37NSC60 3PD 50A1422KW44NSC60 3PD 60
2、A1530KW59NSC100 3PD 80A1637KW72NSC100 3PD 100A1745KW85NSC100 3PD 100A1855KW105NSC160 3PD 125A1975KW140NSC160 3PD 160A2090KW170NSC250 3PD 225A21110KW210NSC250 3PD 250A22132KW250NSC400 3PD 320A低低压压电电动动机机功功率率电电流流电电缆缆选选型型对对应应表表功率(KW)电流(A)电缆选用(最佳)电缆选用(最小)1.12.24*2.52.24.44*2.536.24*2.548.24*2.55.511.13*4
3、+1*2.57.514.33*4+1*2.51121.63*6+1*41530.13*10+1*618.536.53*16+1*62240.53*16+1*63057.63*25+1*163769.93*25+1*164583.93*35+1*165597.23*50+1*253*35+1*1665104.73*70+1*353*50+1*2575139.63*70+1*353*70+1*35901663*95+1*503*70+1*351102173*120+1*703*95+1*501322383*150+1*703*95+1*502003513*240+1*1203*185+1*9522
4、03893*240+1*1203*185+1*952804892*(3*185+1*95)2*(3*185+1*95)3155562*(3*185+1*95)2*(3*185+1*95)接触器热继电器LC1-D09LRD06(11.6)LC1-D09LRD07(1.62.5)LC1-D09LRD08(2.54)LC1-D09LRD08(2.54)LC1-D18LRD10(46)LC1-D18LRD12(5.58)LC1-D25LRD14(710)LC1-D25LRD16(913)LC1-D32LRD21(1218)LC1-D32LRD22(1725)LC1-D40LRD22(1725)LC1-D50LRD32(2332)LC1-D50LR9 F53 57(3050)LC1-D50LR9 F53 57(3050)LC1-D65LR9 F53 57(3050)LC1-D80LR9 F53 63(4880)LC1-D95LR9 F53 67(60100)LC1-D150LR9 F53 69(90150)LC1-F150LR9 F53 69(90150)LC1-F185LR9 F53 71(132220)LC1-F225LR9 F53 71(132220)LC1-F265LR9 F73 75(200330)