1、PXIe-5668Getting Started2023-03-01PXIe-5668 Getting StartedContentsGetting Started with the PXI-5661.3Electromagnetic Compatibility Guidelines.3Verifying the System Requirements.4Unpacking the Kit.4Verifying the Kit Contents.5Preparing the Environment.6Choosing and Installing the Software.7Software

2、Options.7Installing the Software.8Installing the PXIe-5668.8Interconnecting the PXIe-5668 Modules.11Configuring the PXIe-5668 in MAX.27Self-Calibration.28Performing a Device Self-Calibration Using the NI-RFSA SFP.29Locating the Software and Examples.29Software Locations.29Programming Examples Locati

3、ons.31Troubleshooting.32Installation.32Configuration.34Measurements.35Where to Go Next.36Nl Services.36/PXIe-5668 Getting StartedGetting Started with the PXI-5661|Note Before you begin,install and configure your chassis and controller.This document explains how to install,configure,and test the PXIe

4、-5668.The PXIe-5668 is a 26.5 GHz or 14 GHz modular vector signal analyzer(VSA).The PXIe-5668 ships with the NI-RFSA instrument driver,which you use to program the device.You can also use NI-RFmx,available at program the device.The PXIe-5668 comprises the following devices:PXIe-5606 RF Signal Downco

5、nverter(PXIe-5606)RF downconverter PXIe-5624 IF Digitizer(PXIe-5624)intermediate frequency(IF)digitizer PXIe-5653 RF Analog Signal Generator(PXIe-5653)synthesizer/local oscillator(LO)source moduleA Caution The protection provided by this product may be impaired if it is used in a manner not describe

6、d in this document.Hot Surface If the PXIe-5668 has been in use,it may exceed safe handling temperatures and cause burns.Allow the PXIe-5668 to cool before removing it from the chassis.Note In this document,PXIe-5668 refers to both the PXIe-566826.5 GHz VSA and the PXIe-566814 GHz VSA unless otherwi

7、se specified.2014-2021 National Instruments Corporation.All rights reserved.Refer to the _Legal Information directory for information about Nl copyright,patents,trademarks,warranties,product warnings,and export compliance.National InstrumentsPXIe-5668 Getting StartedElectromagnetic Compatibility Gui

8、delinesThis product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility(EMC)stated in the product specifications.These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended ope

9、rational electromagnetic environment.This product is intended for use in industrial locations.However,harmful interference may occur in some installations,when the product is connected to a peripheral device or test object,or if the product is used in residential or commercial areas.To minimize inte

10、rference with radio and television reception and prevent unacceptable performance degradation,install and use this product in strict accordance with the instructions in the product documentation.Furthermore,any changes or modifications to the product not expressly approved by Nl could void your auth

11、ority to operate it underyour local regulatory rules.A Caution To ensure the specified EMC performance,operate this product only with shielded cables and accessories.A Caution To ensure the specified EMC performance,operate this product only with cables less than 3 meters in length.Verifying the Sys

12、tem RequirementsTo use the PXIe-5668,your system must meet certain requirements.For more information about minimum system requirements,recommended system,and supported application development environments(ADEs),refer to the readme,which is installed or available at the KitNotice To prevent electrost

13、atic discharge(ESD)from damagingthe device,ground yourself using a grounding strap or by holding a grounded object,such as your computer chassis.4 PXIe-5668 Getting Started1.Touch the antistatic package to a metal part of the computer chassis.2.Remove the device from the package and inspect the devi

14、ce for loose components or any other sign of damage.|Notice Never touch the exposed pins of connectors.|Note Do not install a device if it appears damaged in any way.3.Unpack any other items and documentation from the kit.Store the device in the antistatic package when the device is not in use.Verif

15、ying the Kit ContentsFigure 4.PXIe-5668 Kit Contents and Replacement Part Numbers00J1.PXIe-5624 IF Digitizer Module2.PXIe-5606 RF Downconverter Module3.PXIe-5653 Synthesizer/LO Source Module National InstrumentsPXIe-5668 Getting Started4.SMA-to-SMA Cable,Labeled V,Part Number 152638A-015.SMA-to-SMA

16、Cable,Labeled W,Part Number 152639A-016.SMA-to-SMA Cable,Labeled U,Part Number 152637A-017.SMA-to-SMA Cable,Labeled Y,Part Number 152641A-018.SMA-to-SMA Cable,Labeled X,Part Number 152640A-019.SMA Driver Bit,Part Number 190487B-0110.RF Torque Screwdriver,Part Number 780487-0111.Screwdriver,Part Numb

17、er 772006-0112.50 Q Loads(x3),Part Number 778353-0113.Driver Software DVD14.Read Me First:Safety and Electromagnetic Compatibility15.Maintain Forced-Air Cooling Note to Users16.PXIe-5668 Getting Started Guide(This Document)Note The three 50 Q loads are shipped installed on the downconverter front pa

18、nels.Other EquipmentThere are several required items not included in your device kit that you need to operate the PXIe-5668.Your application may require additional items not included in your kit to install or operate your device.A PXI Express chassis and chassis documentation.The PXIe-1085 chassis i

19、s one available option for your device.For more information about compatible chassis options,refer to .An embedded controller or MXI controller system that meets the system requirements specified in this guide and chassis documentation.Preparing the EnvironmentEnsure that the environment you are usi

20、ng the PXIe-5668 in meets the following specifications.6 PXIe-5668 Getting StartedOperating ambient temperature(IEC 60068-2-1,IEC 60068-2-2)0 to 55 Operating relative humidity(IEC 60068-2-56)10%to 90%,noncondensingMaximum altitude2,000 m(800 mbar)(at 25 ambient temperature)Pollution Degree2Indoor us

21、e only.Notice Clean the hardware with a soft,nonmetallic brush or lint free cloth.Make sure that the hardware is completely dry and free from contaminants before returning it to service.Note Refer to the PXIe-5668 Specifications at for complete specifications.Software OptionsNl provides several soft

22、ware options for the PXIe-5668NI-RFmx,the NI-RFSA instrument driver software,and the NI-RFSA Soft Front Panel(SFP).Software OptionDescriptionUse CaseNI-RFmxProvides a single-handle instrument driver with built-in measurements.Use NI-RFmx SpecAn to perform spectral measurements.Use NI-RFmx Demod to p

23、erform modulation quality measurements,such as EVM.Use NI-RFmx cellular personalities to perform physical layer measurement analysis on supported cellular signals.NI-RFSA instrument driverThe NI-RFSA APIs each provide a fixed API for interacting with your PXIe-5668 device.Use NI-RFSA to create custo

24、m measurements or applications that require l/Q data.National InstrumentsPXIe-5668 Getting StartedTable 1.PXIe-5668 Software OptionsSoftware OptionDescriptionUse CaseNI-RFSASFPNI-RFSA provides standard IVI-based functionality needed for most vector signal analyzer applications.Controls,analyzes,and

25、presents data similar to standalone RF vector signal analyzers.The NI-RFSA SFP operates on the PC,so it provides processing,storage,and display capabilities.Use NI-RFSA along with the Nl Modulation Toolkit to analyze modulated signals to test receivers.Use the NI-RFSA SFP to interactively acquire da

26、ta.Installing the SoftwareYou must be an Administrator to install Nl software on your computer.1.Install an ADE,such as LabVIEW or LabWindows/CVI.2.Download the driver software installer Package Manager downloads with the driver software to handle the installation.Refer to the Nl Package Manager Man

27、ual for more information about installing,removing,and upgrading Nl software using Nl Package Manager.3.Follow the instructions in the installation prompts.Note Windows users may see access and security messages during installation.Accept the prompts to complete the installation.4.When the installer

28、 completes,select Restart in the dialog box that prompts you to restart,shut down,or restart later.Installing the PXIe-5668Notice To prevent damage to the PXIe-5668 caused by ESD or contamination,handle the module using the edges or the metal bracket.8 PXIe-5668 Getting Started步 NoteYou must install

29、 NI-RFSA before installing the hardware.Before you install the hardware,refer to the guidelines in the Maintain Forced-Air Cooling Note to Users included with the module to ensure that the device can cool itself effectively.To use the included cables,you must install the PXIe-5624 IF digitizer immed

30、iately to the left of the PXIe-5606 RF downconverter module,and you must install the PXIe-5653 LO source module immediately to the right of the PXIe-5606 RF downconverter module.1.Ensure the AC power source is connected to the chassis before installing the module.The AC power cord grounds the chassi

31、s and protects it from electrical damage while you install the module.2.Power off the chassis.3.Inspect the slot pins on the chassis backplane for any bends or damage prior to installation.Do not install a module if the backplane is damaged.4.Remove the black plastic covers from all the captive scre

32、ws on the module front panel.5.Identify a supported slot in the chassis.The following figure shows the symbols that indicate the slot types.Figure 2.Chassis Compatibility Symbols1.PXI Express System Controller Slot2.PXI Peripheral Slot3.PXI Express Hybrid Peripheral Slot4.PXI Express System Timing S

33、lot5.PXI Express Peripheral Slot National InstrumentsPXIe-5668 Getting StartedPXIe-5668 modules can be placed in PXI Express peripheral slots,PXI Express hybrid peripheral slots,or PXI Express system timing slots.6.Touch any metal part of the chassis to discharge static electricity.7.Ensure that the

34、 ejector handle is in the downward(unlatched)position.8.Place the module edges into the module guides at the top and bottom of the chassis.Slide the module into the slot until it is fully inserted.Figure 1.Module Installation1.Chassis2.Hardware Module3.Ejector Handle in Downward(Unlatched)Position9.

35、Latch the module in place by pulling up on the ejector handle.10.Secure the module front panel to the chassis using the front-panel mounting screws./Note Tightening the top and bottom mounting screws increases mechanical stability and also electrically connects the front panel to the chassis,which c

36、an improve the signal quality and electromagnetic performance.11.Cover all empty slots using either filler panels(standard or EMC)or slot blockers with filler panels,depending on your application.10 PXIe-5668 Getting StartedNote For more information about installing slot blockers and filler panels,g

37、o to on the chassis.Related tasks:Installing the SoftwareInterconnecting the PXIe-5668 ModulesComplete the following steps to interconnect the PXIe-5668 front panel connectors,as shown in the following figure.Notice The signal pins of this products input/output ports can be damaged if subjected to E

38、SD.To prevent damage,remove power from the product before connecting cables and employ industry-standard ESD prevention measures during installation,maintenance,and operation.National InstrumentsPXIe-5668 Getting StartedFigure 4.Installation of the PXIe-5668 Cables and 50 F LoadsWeNATIONAL 尸 INSTRUM

39、ENTS Nl PXIe-5624R 2GS,%IFDigitim OOACCESS ACTMWWREFIN6VptMAXREF OUT100 MHl1.5 V MAXOOACCESS ACTIVENATIONAI 产 INSTRUME ITSNl PXIe-560 画.画7 NATIONAL 产 INSTRUMENTSNl PXIe-5653SynthesizerooILK INDIGITAL I/OALL.PORTSLT=1 IN 13 dBm MAXCLK OUT1.SMA-to-SMA Cable,Labeled V2.SMA-to-SMA Cable,Labeled U3.50 O

40、Load4.SMA-to-SMA Cable,Labeled Y5.SMA-to-SMA Cable,Labeled X6.SMA-to-SMA Cable,Labeled W1.Using the three SMA-to-SMA coaxial cables labeled W,X,and Y,connect the LOI,LO2,and LO3 connectors on the Nl 5653 front panel to the associated LOI IN,LO2 IN,and LO3 IN connectors on the PXIe-5606 front panel.2

41、.Using the SMA-to-SMA cable labeled U,connect the LO2 OUT connector on the Nl 5606 front panel to the CLK IN connector on the Nl 5624R front panel.3.Using the SMA-to-SMA cable labeled V,connect the IF OUT connector on the PXIe-5606 front panel to the IF IN connector on the Nl 5624R front panel.上 PXI

42、e-5668 Getting Started4.Install a 50 Q load on each of the PXIe-5606 module LOI OUT,LO3 OUT,and IF IN/BIAS OUT connectors.5.Hand-tighten all SMA cable ends on the SMA connectors after the cable center pins are correctly aligned and connected.The cable connectors should tighten without much torque or

43、 effort.Note If the SMA cable does not exactly align with the SMA connector,bend the cable slightly by hand to align the cable and the connector.The amount of bending should be minimal.The cables can be damaged by excessive bending.6.Carefully complete tightening all SMA connectors to 1 N-m using an

44、 appropriate torque wrench(not included)or torque screwdriver and SMA driver bit.Tighten only until the wrench clicks.A Caution Incorrect torque at SMA connections can damage device connectors,degrade signal fidelity and phase locked loop performance,or cause insertion loss.Use an appropriate torque

45、 wrench ortorque screwdriver and SMA driver bit to ensure all SMA connections are properly torqued.SMA connectors for connections to external equipment may require torque different from 1 N m,dependingon the connector type,material,and manufacturer.7.Power on your PXI Express chassis and controller

46、system.If you are using a MXI device and a remote controller,ensure that the chassis is powered on prior to triggering the remote controller.Using the controller system before the chassis is powered on may cause installed devices to not appear in MAX.8.Verify that the ACCESS LED is on for all three

47、modules.Related concepts:TroubleshootingRelated information:National InstrumentsPXIe-5668 Getting Started Refer to the Nl RFVector Signal Analyzers Help for information about how to make connections using an external dock,or how to connect multiple Nl 5668R modules.Direct Connections to the PXIe-560

48、6The PXIe-5606 is a precision RF instrument that is sensitive to ESD and transients.Ensure you are making proper direct connections to the PXIe-5606 to avoid damaging the device.Notice Apply external signals only while the PXIe-5606 is powered on.Applying external signals while the device is powered

49、 off may cause damage.Ensure you are properly grounded when manipulating cables or antennas connected to the PXIe-5606RF IN connector.If you are using noninsulated devices,such as an RF antenna,ensure the devices are maintained in a static-free environment.If you are using an active device,such as a

50、 preamplifier or switch routed to the PXIe-5606RF IN connector,ensure that the device cannot generate signal transients greater than the RF and DC specifications of the PXIe-5606RF IN connector.PXIe-5606 RF Downconverter ModuleThe PXIe-5606 RF downconverter module front panel contains eight connecto

展开阅读全文
相似文档                                   自信AI助手自信AI助手
猜你喜欢                                   自信AI导航自信AI导航
搜索标签

当前位置:首页 > 通信科技 > 软件工程

移动网页_全站_页脚广告1

关于我们      便捷服务       自信AI       AI导航        获赠5币

©2010-2024 宁波自信网络信息技术有限公司  版权所有

客服电话:4008-655-100  投诉/维权电话:4009-655-100

gongan.png浙公网安备33021202000488号   

icp.png浙ICP备2021020529号-1  |  浙B2-20240490  

关注我们 :gzh.png    weibo.png    LOFTER.png 

客服