收藏 分销(赏)

使用Mnova在您的桌面上处理、分析和报告NMR和LC∕GC∕MS 英文版.ppt

上传人:wei****ing 文档编号:12939948 上传时间:2025-12-27 格式:PPT 页数:42 大小:3.05MB 下载积分:5 金币
下载 相关 举报
使用Mnova在您的桌面上处理、分析和报告NMR和LC∕GC∕MS 英文版.ppt_第1页
第1页 / 共42页
使用Mnova在您的桌面上处理、分析和报告NMR和LC∕GC∕MS 英文版.ppt_第2页
第2页 / 共42页


点击查看更多>>
资源描述
Click to edit Master title style,Click to edit Master text styles,Second level,Third level,Fourth level,Fifth level,*,*,Using Mnova to Process,Analyze and Report,NMR and LC/GC/MS on Your Desktop,Chen Peng,PhD,Director of Business Development,US&China,Mestrelab Research SL,San Diego,CA,(858)736-4563,chen.peng,Version 6.2,March,2011,Use,Mnova NMR,to,Open and transform your NMR data,Process,analyze and report a,1,H spectrum,Use,Mnova NMRPredict Desktop,to,Predict,1,H and,13,C and verify your structure,Assist you assign peaks,Use,Mnova MS,to,Open your LC/MS raw data and browse MS and UV,Verify your proposed structures,Contents*,*Only the most routinely used features are covered.More advanced features,as well as,Mnova,DB(database),ASV(auto structure verification)and Assign plugins are not covered in this,tutorial,.,NMR,NMR,Predict,MS,DB,ASV,Assign,Mnova,:An integrated system for analytical chemistry,Mnova,is compatible with Mac,Windows and Linux,Mnova NMR,Quickly process and analyze 1D NMR,and report your chemical shifts and J-couplings in journal format,Process,analyze and assign multiple 2D spectra together with 1D*,Advanced tools for automation,quantitation,reaction monitoring,diffusion&relaxation studies*,Mnova NMR license required,*Those features are not illustrated in this tutorial.See Mnova,Help Contents,for more details,NMR,NMR,Predict,MS,DB,ASV,Assign,Mnova:An integrated system for analytical chemistry,To open and transform your NMR data,Choose,File|Open,to open the,fid,file from the raw data,O,r drag an,fid,file from Windows Explorer to,Mnova,*,Mnova,automatically transforms the raw file into frequency domain,(,including Windowing function,Fourier transform,phase correction,etc,),*,*You can drag,multiple folders,that contain,fid,(or,ser,)to Mnova to open multiple spectra simultaneously.,*Parameters from the raw data are used for processing.You can view or change the processing parameters by choosing,Processing|Processing Parameters.,See,Help Contents Processing Basics,for more details,Drag&drop,Click for,phase correction,if peaks are not symmetric*,C,lick for,baseline correction,if baseline is not zero*,C,lick to calibrate the,chemical shift reference,if the solvent or TMS peak is not at the right ppm,*Click the arrow next to the tool icon for options.,See,Help Contents Processing Basics,for more details,To correct,phase,baseline&reference,Zoom in/Zoom out(or,press Z,)*,Zoom out,Full spectrum(or,press F,),Manual Zoom in to defined ppm range,Pan spectrum(or,press P,)*,Expansion,click&drag,to draw an inset(or,press E,),Fit to Height(or,press H,),Increase Intensity(or rotate mouse wheel),Decrease Intensity(or rotate mouse wheel),Crosshair Cursor(or,press C,)for measuring,J,-couplings,Cut(or,press X,)to hide parts of the spectrum,To visualize your spectrum,*Press Z several times to toggle between horizontal/vertical/box zoom,*,Press P several times to toggle between free/horizontal/vertical panning,Press,E,then Click and drag to define the range for the inset,To analyze and report multiplets in H-1 NMR,Mnova,provides several approaches,to,multiplet,analysis,M,anual:click-and-drag to pick each,multiplet,interactively,Semi-auto:pick peaks and integrate first,then do auto,multiplet,analysis,Fully automatic,multiplet,analysis,In either case you can refine the results interactively,and report them in selected journal or patent formats,To analyze multiplets manually,Press,Z,and zoom into one or more multiplets,Press,J,to switch to Manual Multiplet mode,Click and drag to include peaks for a multiplet*,Double click on the multiplet label to open the,Multiplet Manager Panel,(see next slide),Choose,View|Full View,to show the Full View window if you want(see next slide),Click and drag to define the,range,and,peak picking threshold,for the doublet,*Mnova 6.1 or older:You can only define the range but not the threshold.The automatic peak picking threshold is used for picking peaks.,Full view and zoom-in view for,multiplet,analysis,Full View,:The whole spectrum and zoom-in area.Drag the blue box to move to other,multiplets,.(Choose View|Full View to open it),Manual,multiplet,analysis,:Press,J,then click and drag to define,the range and peak picking threshold for a,multiplet,.,Multiplet,Manager,shows the properties of the current,multiplet,picked.(Double click on a,multiplet,label to open it),Multiplet,label,:Hover the cursor on it to see peaks.Use the bar to split a,multiplet,To refine,multiplet,analysis results,Hover the cursor on the multiplet label to show the peaks in the multiplet,Click/drag the small red box to split the multiplet at desired place,You can also click/drag the small green boxes to change the range of a multiplet,Use the small red box to split a multiplet,Use the small green boxes to change the range of a multiplet,To,refine,multiplet,analysis results,Select the Add Multiplet Peak tool,Click SHIFT key once to switch to free peak picking mode,Click on the shoulder peak at around 3.09 ppm,Click here to pick the missing shoulder,peak.Note:you may need to click SHIFT key to exit the auto peak picking mode to pick it.,To refine,multiplet,analysis results,The new peak is added to multiplet C because it falls in the range of multiplet C,Click on that peak and drag it to multiplet B,It belongs to multiplet B now,and the multiplet patterns are auto.updated,Drag this peak to the label of,multiplet,B,Multiplet,Manager,Use the Multiplet Manager to inspect and change the properties of a multiplet,Move to the Previous/Next multiplet,Delete the current multiplet,Add/Delete multiplet peaks,Properties of the current multiplet,Normalized integral and nuclide counts,Chemical shift range of the multiplet,The current#of protons included in the multiplets.,To report,multiplets,Click,Multiplet Analysis|Report,to report the results in a journal format:,T,o change journal format:choose,View|Tables|Multiplets,to display the Multiplets Table.Click,Setup Report,1,H NMR(400 MHz,CDCl,3,)8.62(d,J,=4.5 Hz,1H),7.95(d,J,=9.2 Hz,1H),7.46(d,J,=4.5 Hz,1H),7.30(dd,J,=9.2,2.7 Hz,1H),7.21(d,J,=2.7 Hz,1H),5.80 5.66(m,1H),5.48(d,J,=4.1 Hz,1H),4.92(ddt,J,=13.3,10.3,1.4 Hz,2H),3.87(s,3H),3.46 3.27(m,2H),3.18 3.00(m,2H),2.63(ddd,J,=12.6,7.1,3.9 Hz,2H),2.32 2.08(m,1H),1.90(s,2H),1.83 1.63(m,3H),1.51(dddd,J,=12.4,7.3,5.7,2.5 Hz,2H).,Tip:From the Multiplet Table,click,Copy Multiplets,and then paste the texts to your document.Click,Copy Table,and then paste the spreadsheet to your document.The table can be customized using,Setup Table.,Semi-automatic multiplets analysis,1,st,:Do peak picking.Clean up the peaks,2,nd,:Do integration.Clean up the integrals,3,rd,:Do auto.,multiplet,analysis for the whole spectrum based on,those,peaks and integrals,Finally edit and report the,multiplet,results as described in the previous slides,Region and threshold to pick peaks,To pick peaks,Click to do,auto peak picking,.If results are not good,click Options to change the threshold:*,O,r choose,Manual Threshold,(or press,K,),click&drag to define the region and threshold to pick peaks,C,hoose,Peak by Peak,(or press,Ctrl+K,)to pick one peak at a time*,*Threshold is the(auto estimated),Noise,L,evel,multiplied by the Noise Factor(user-defined).,*By default,Mnova,automatically locates the peak tops.Click,Shift,key to turn it off when picking shoulder peaks.,Tip:Choose,Edit|Properties,to change the way to display peaks,Threshold for picking positive and negative peaks,To integrate peaks,Click to do auto integration,Double click on an integral curve to popup Integral Manager:,T,ype a Normalized value to normalize the integrals,Browse,delete,change,split integrals interactively if needed,Click and drag the left green box to change the range of the integral,Tip:You can click and drag an integral curve to move them up or down,and change their sizes.,See,Help Contents Analysis tools Integration,for more details.,Automatic multiplet analysis,Click to do peak picking,integration and multiplet analysis fully automatically,Next browse and refine the results as described in the previous slides,Tips,:A suitable peak picking threshold is critical to the performance.See previous slides about it.,Peaks and integrals are not labeled.Peaks are shows when you hover the cursor on a multiplet label.,By default,the J coupling constants are not displayed in the labels.Right click and select Properties to turn it on.,Choose,Scripts|R,to report in a predefined format,Click to generate PDF,or copy/paste to your documents,To report using the,R,script*,*You need to install R script.Write to,sales,to request for it.,Tip:You can copy a,molecule,from ChemDraw,Isis/Draw or ChemSketch,or open.mol or.sdf files.,To annotate and report manually,Click the,Annotation Options,button at the bottom-left corner of Mnova window,Or press,T,to insert a text box,All objects can be customized by right clicking on it and then selecting the,Properties,command,Tables of Peaks,Integrals,Parameters,etc can be opened by,View|Tables.,Report from there,Tips:,*Copy a,molecule,from,ChemDraw,or Isis/Draw,or open.,mol,or.,sdf,files,*Use,View|Layout Templates,menu to generate and apply layout templates,or request an auto,formatting script,from Mestrelab.,*,Copy/paste,any object(s)to your document with high resolution,*Click to export,PDF,Mnova,NMRPredict Desktop,Predict,1,H,13,C,15,N,17,O,19,F,29,Si,and,31,P spectra,Predict and verify a structure and do peak assignment interactively,Mnova NMRPredict Desktop license required,NMR,NMR,Predict,MS,DB,ASV,Assign,Mnova:An integrated system for analytical chemistry,To predict NMR from a structure,Open a new document(,File|New,)or a new page(,Edit|Create New Page,),Copy a structure from ChemDraw,Isis/Draw or ChemSketch,and paste to Mnova,or open a.mol or a.sdf file,Choose an option from the,Predict,menu,Tips:,1.Choose,Molecules|Prediction Options,to change settings,2.You can turn on/off the atom numbers by right-clicking on the structure and choose Properties.,To predict NMR&verify your structure,Open your,1,H(or,13,C),spectrum,in a new page,Copy your,structure,from ChemDraw or Isis/Draw,Choose,Analysis|Predict&Compare.,The predicted spectrum is stacked with the experimental one for visual comparison,Hover your cursor on the atom to highlight its predicted peak,To assign NMR multiplets to atoms(1),Do,Multiplet Analysis,to get the multiplet labels,D,o,Predict and Compare,Change the stacking mode to“,Active Spectrum,”,press Shift+Up Arrow Key to make sure the experimental spectrum is displayed(so that the multiplet labels are visible),Hover the cursor on an atom to see its predicted peak(in blue).,Press,A,and click on an atom to assign,Click on the multiplet label to assign to that atom,Tips:,1.The predicted spectrum helps you assign peaks,but you dont have to have it for assignment.,2.After,Predict and Compare,the two spectra are stacked.In the Stacked Mode,the multiplet labels are not displayed.You have to change to Active Spectrum mode to see the multiplet labels.,2.Press,ESC,to exit assignment mode.,3.Choose,View|Tables|Assignment,to report the assignments.,4.Multiple 1D and 2D spectra can be assigned simultaneously in this way.,To assign NMR multiplets to atoms(2),Hover the cursor on the atom(#8)to assign.The predicted peak is displayed as the blue doublet.,Click on atom#8 and then on this,multiplet,label to,assign,it to atom#8.,To assign NMR peaks to atoms without multiplet analysis,Do,Predict and Compare,first,Press,A,and click on an atom to assign,Click and drag on the experimental spectrum to include the multiplet to assign,Or click on a peak top to assign,Tips:,1.The predicted spectrum helps you assign peaks,but you dont have to have it.,2.Press,ESC,to exit assignment mode.,3.Choose,View|Tables|Assignment,to report the assignments.,4.Multiple 1D and 2D spectra can be assigned simultaneously in the same document.,5.Use,Predict|Update 1H (or 13C)User DB,to save your assignment for improving the prediction(Mnova 6.2 only),Click on the atom(#8)to assign.It highlights its predicted peak.,Click and drag to define the peak to be assigned to this atom(#8).,Mnova,MS,Mnova:An integrated system for analytical chemistry,Visualize your LC/GC-MS data and UV components from various vendors,Integrate peaks automatically or manually with easy reporting,Verify proposed structures by matching mol ion and isotope peaks,Enumerate possible elemental compositions from a selected ion peak,Mnova MS license required,NMR,NMR,Predict,MS,DB,ASV,Assign,Agilent,ChemStation,M,assHunter,I,on Trap,Mnova MS:Open raw data automatically,Thermo,Xcalibur,Waters,MassLynx,Bruker,Xmass,Compass,Raw data,Drag&drop,ABI/SCIEX,Analyst,JEOL,MSQ1000,Shimadzu,See,http,:/more details and limitations.,NMR,spectra can be opened in the same document.Molecular structures can be opened as.,mol,or.,sdf,files,or be copied from,ChemDraw,Isis/Draw and,ChemSketch,.,To open your LC/MS data,Choose,File|Page Setup|Orientation,and change the page orientation to portrait,if you prefer.,Choose,File|Open,to open any file in the folder containing the raw data,or,drag/drop,the folder from Windows Explorer to Mnova,Mnova automatically converts your data and does peak integration.,Drag&drop,TIC,MS trace,To browse the MS traces,Click to switch to crosshair cursor,and click on the TIC to display the MS trace at that retention time.,Click to change to appending mode if you want to display multiple MS traces,Choose the Spectrum Selection Mode options to display co-added MS traces:,To browse the UV traces,Click to show the,MS Browser Panel,Choose the,Total UV Absorbance,under,Traces,and Click to display the UV TIC,Repeat the above step to display the other UV components if any,To edit and report peak integration results,Peaks are automatically integrated when you open a chromatogram,Use the,Peak Detection,tool menu to re-detect peaks,add,delete or clear peaks,Hover your cursor on the wedges,click and drag the green boxes to change the range of a peak,Or press Shift,click and drag the green boxes to change the baseline of a peak,Choose,View|Tables|Mass Peaks,to display or report the Mass Peaks Table,TIC,SHIFT+,Drag,To display extracted ion chromatogram(EIC)from an m/z value,Click (or choose,Mass Analysis|New Mass Chromatogram|Manually,),In the New Chromatogram dialog,enter the m/z value that you are interested in,and a suitable Tolerance,Press OK to display the EIC,TIC,EIC at 195.1+/-0.25 Da,To display extracted ion chromatogram(EIC),for an MS peak,First display the MS trace and zoom into the molecular ion peak that you are interested.,Next select Click (or choose,Mass Analysis|New Mass Chromatogram|Graphically,),click-and-drag around the peak to define a mass range,An EIC will be displayed within the mass range,TIC,MS at 0.63 min,EIC at 194.8-195.6 Da,To confirm proposed structures using,Molecule Match(1),Throw in one or several structures by copy/pasting from ChemDraw,Isis/Draw or ChemSketch,or by opening.mol or.sdf files.,Click (or choose,Mass Analysis|Molec
展开阅读全文

开通  VIP会员、SVIP会员  优惠大
下载10份以上建议开通VIP会员
下载20份以上建议开通SVIP会员


开通VIP      成为共赢上传

当前位置:首页 > 教育专区 > 其他

移动网页_全站_页脚广告1

关于我们      便捷服务       自信AI       AI导航        抽奖活动

©2010-2025 宁波自信网络信息技术有限公司  版权所有

客服电话:0574-28810668  投诉电话:18658249818

gongan.png浙公网安备33021202000488号   

icp.png浙ICP备2021020529号-1  |  浙B2-20240490  

关注我们 :微信公众号    抖音    微博    LOFTER 

客服