1、单击此处编辑母版标题样式,单击此处编辑母版文本样式,第二级,第三级,第四级,第五级,*,*,2013,产品配置指导,-FlexServer,机架和刀片服务器,1,FlexServer R390 2,路机架服务器,配置指导,2,第一步:选择主机(必配),9801A0EV,VC-FSR-R390-Z-L1,H3C FlexServer R390,2*E5-2609,2*4GB,2*500G SAS 7.2K,4*GE,网卡,460W,机架导轨,机架服务器,9801A0EW,VC-FSR-R390-Z-M1,H3C FlexServer R390,2*E5-2620,2*8GB,2*300G SAS
2、 10K,4*GE,460W,机架导轨,机架服务器,9801A0EX,VC-FSR-R390-Z-H1,H3C FlexServer R390,2*E5-2650,4*8GB,2*300G SAS 10K,4*GE,460W,机架导轨,机架服务器,9801A0EY,VC-FSR-R390-Z-F1,H3C FlexServer R390,2*E5-2690,8*8GB,3*146G SAS 15K,4*GE+2*10GE(FCoE),网卡,750W,机架导轨,机架服务器,第二步:增配内存(选配,总共,24,个内存插槽),0202A0C8,DDR3L-4GB-SR*4-MR,4GB PC3L-1
3、0600R(DDR3-1333),内存模块,0202A0BK,DDR3-8GB-SR*4-HR,8GB PC3-12800R(DDR3-1600),内存模块,注意:增配的内存规格必须与原服务器标配的内存完全一致。,2,路服务器,8G,内存必须选择,1600M,,,4,路服务器,8G,内存必须选择,1333M,3,第三步:增配硬盘(选配,总共,8,个硬盘位),0202A0BN,HD-500G-SAS-7200-SFF,500GB 6G-SAS-7.2K-2.5,英寸硬盘模块,0202A0BP,HD-300G-SAS-10K-SFF,300GB 6G-SAS-10K-2.5,英寸硬盘模块,0202
4、A0BQ,HD-146G-SAS-15K-SFF,146GB 6G-SAS-15K-2.5,英寸硬盘模块,第四步:选择,RAID,卡缓存(选配,建议配置),0202A0C7,FBWC-512MB-SmtAry,512MB,磁盘阵列高速缓存模块,0202A0BV,FBWC-1GB-SmtAry,1GB,磁盘阵列高速缓存模块,0202A0BW,FBWC-2GB-SmtAry,2GB,磁盘阵列高速缓存模块,注意:如果增配的硬盘和原服务器标配的硬盘属于同一个,RAID,组,则增配的硬盘,规格必须和原硬盘一致;如果不属于同一个,RAID,组,则增配的硬盘规格可,以和原硬盘规格不一致。,4,第五步:增配网
5、卡及光模块(选配,共,6,个网卡插槽),0202A0C9,NIC-GE-4P-331T,4,端口,GE,以太网卡,331,T(,扩展网卡,),0202A0BR,NIC-10GE-2P-530SFP,2,端口,10GE,以太网卡,(,扩展网卡,),0202A0BS,NIC-10GE-2P-CNA,2,端口,10,GE CNA,网卡,(,FCoE,扩展网卡,),0202A0BY,HBA-8Gb-2P-82B,82B 8Gb-2port-PCIe,光纤通道,HBA,卡,0202A0C0,HBA-8Gb-2P-82E,82E 8Gb-2port-PCIe,光纤通道,HBA,卡,0202A0C1,HBA
6、8Gb-2P-82Q,82Q 8Gb-2port-PCIe,光纤通道,HBA,卡,0231A0A6,SFP-XG-SX-MM850-A,SFP+,万兆模块,(850,nm,300m,LC),注意:,HBA,卡已标配光模块;,10GE,网卡没有标配光模块,需要另配,第六步:选择光驱(选配),0202A0BT,DVD-ROM-Slim-SATA,12.7,毫米超薄,SATA DVD,只读光驱,0202A0BU,DVD-RW-Slim-SATA,12.7,毫米超薄,SATA DVD,可写光驱,5,第七步:增配冗余电源(选配,共,2,个电源插槽),0202A0BL,PWR-460W-CSG,460W
7、通用插槽热插拔高效电源,0202A0BM,PWR-750W-CSG,750W,通用热插拔高级电源模块,注意:电源不能混插,低、中、高服务器必须配置,460W,,,FCOE,款型必须配置,750W,6,FlexServer R590 4,路机架服务器,配置指导,7,第一步:选择主机(必配),9801A0HM,VC-FSR-R590-Z-L1,H3C FlexServer R590,2*E5-4607,2*8GB,2*300G SAS 10K,4*GE,网卡,1200W,机架导轨,机架服务器,9801A0HN,VC-FSR-R590-Z-L2,H3C FlexServer R590,4*E5-4
8、607,4*8GB,2*300G SAS 10K,4*GE,网卡,1200W,机架导轨,机架服务器,9801A0HP,VC-FSR-R590-Z-H1,H3C FlexServer R590,2*E5-4620,2*8GB,2*300G SAS 10K,4*GE,网卡,1200W,机架导轨,机架服务器,9801A0HQ,VC-FSR-R590-Z-H2,H3C FlexServer R590,4*E5-4620,4*8GB,2*300G SAS 10K,4*GE,网卡,1200W,机架导轨,机架服务器,第二步:增配内存(选配,总共,48,个内存插槽),0202A0CC,DDR3-8GB-DR*
9、4-LR,8GB PC3L-10600R(DDR3-1333),内存模块,注意:增配的内存规格必须与原服务器标配的内存完全一致。,4,路服务器,8G,内存必须选择,1333M,,,2,路服务器,8G,内存必须选择,1600M,8,第三步:增配硬盘(选配,总共,5,个硬盘位),0202A0BN,HD-500G-SAS-7200-SFF,500GB 6G-SAS-7.2K-2.5,英寸硬盘模块,0202A0BP,HD-300G-SAS-10K-SFF,300GB 6G-SAS-10K-2.5,英寸硬盘模块,0202A0BQ,HD-146G-SAS-15K-SFF,146GB 6G-SAS-15K-
10、2.5,英寸硬盘模块,注意:如果增配的硬盘和原服务器标配的硬盘属于同一个,RAID,组,则增配的硬盘,规格必须和原硬盘一致;如果不属于同一个,RAID,组,则增配的硬盘规格可,以和原硬盘规格不一致。,第四步:选择,RAID,卡缓存(选配,建议配置),0202A0C7,FBWC-512MB-SmtAry,512MB,磁盘阵列高速缓存模块,0202A0BV,FBWC-1GB-SmtAry,1GB,磁盘阵列高速缓存模块,0202A0BW,FBWC-2GB-SmtAry,2GB,磁盘阵列高速缓存模块,9,第五步:增配网卡及光模块(选配,共,6,个网卡插槽),0202A0C9,NIC-GE-4P-331
11、T,4,端口,GE,以太网卡,331,T(,扩展网卡,),0202A0BR,NIC-10GE-2P-530SFP,2,端口,10GE,以太网卡,(,扩展网卡,),0202A0BS,NIC-10GE-2P-CNA,2,端口,10,GE CNA,网卡,(,FCoE,扩展网卡,),0202A0BY,HBA-8Gb-2P-82B,82B 8Gb-2port-PCIe,光纤通道,HBA,卡,0202A0C0,HBA-8Gb-2P-82E,82E 8Gb-2port-PCIe,光纤通道,HBA,卡,0202A0C1,HBA-8Gb-2P-82Q,82Q 8Gb-2port-PCIe,光纤通道,HBA,卡,
12、0231A0A6,SFP-XG-SX-MM850-A,SFP+,万兆模块,(850,nm,300m,LC),注意:,HBA,卡已标配光模块;,10GE,网卡没有标配光模块,需要另配,第六步:增配冗余电源(选配,总共,2,个电源插槽),0202A0CD,PWR-1200W-CSP,1200W,通用热插拔高级电源模块,10,第七步:选择光驱,注意:,R590,无光驱位,需自行购买,USB,光驱,11,FlexServer 2/4,路刀片服务器,配置指导,12,第一步:选择机箱(必配),9801A0HR,VC-FSR-C8000-Z,H3C FlexServer C8000,4*FAN,1*POWE
13、R,1*OA,单相电源输入,刀片机箱,说明:,C8000,已标配,1,个电源、,4,个风扇、,1,个,OA,管理模块,13,第二步:选择刀片服务器(,支持,16,片,B390,或,8,片,B590,,可混插,),9801A0HS,VC-FSR-B390-Z-L1,H3C FlexServer B390,,,2*E5-2620,,,2*8GB,,,2*10GE Flex10 FLB,网卡,,刀片服务器,9801A0HT,VC-FSR-B390-Z-L2,H3C FlexServer B390,,,2*E5-2620,,,2*8GB,,,2*10GE FlexFabric FLB,网卡,,刀片服务
14、器,9801A0HU,VC-FSR-B390-Z-H1,H3C FlexServer B390,,,2*E5-2650,,,2*8GB,,,2*10GE Flex10 FLB,网卡,,刀片服务器,9801A0HV,VC-FSR-B390-Z-H2,H3C FlexServer B390,,,2*E5-2650,,,2*8GB,,,2*10GE FlexFabric FLB,网卡,,刀片服务器,9801A0HW,VC-FSR-B590-Z-L1,H3C FlexServer B590,,,4*E5-4607,,,2*8GB,,,2*10GE Flex10 FLB,网卡,,刀片服务器,9801A0
15、HX,VC-FSR-B590-Z-L2,H3C FlexServer B590,,,4*E5-4607,,,2*8GB,,,2*10GE FlexFabric FLB,网卡,,刀片服务器,9801A0HY,VC-FSR-B590-Z-H1,H3C FlexServer B590,,,4*E5-4620,,,2*8GB,,,2*10GE Flex10 FLB,网卡,,刀片服务器,9801A0J0,VC-FSR-B590-Z-H2,H3C FlexServer B590,,,4*E5-4620,,,2*8GB,,,2*10GE FlexFabric FLB,网卡,,刀片服务器,说明:,Flex-1
16、0,网卡和,FlexFabric,网卡的唯一区别在于,FlexFabric,比,Flex-10,网卡,多了,FCOE,功能。两者都可以做端口虚拟化,单端口最多可以虚拟为,4,个虚端口,14,第三步:选择硬盘(必配,总共,2,个硬盘位),0202A0BN,HD-500G-SAS-7200-SFF,500GB 6G-SAS-7.2K-2.5,英寸硬盘模块,0202A0BP,HD-300G-SAS-10K-SFF,300GB 6G-SAS-10K-2.5,英寸硬盘模块,0202A0BQ,HD-146G-SAS-15K-SFF,146GB 6G-SAS-15K-2.5,英寸硬盘模块,第四步:增配内存,
17、选配,,B390,共,16,个内存插槽,,B590,共,32,个,),0202A0CC,DDR3-8GB-DR*4-LR,8GB PC3L-10600R(DDR3-1333),内存模块,0202A0BK,DDR3-8GB-SR*4-HR,8GB PC3-12800R(DDR3-1600),内存模块,注意:增配的内存规格必须与原服务器标配的内存完全一致。,4,路服务器,8G,内存必须选择,1333M,,,2,路服务器,8G,内存必须选择,1600M,注意:刀片服务器和机架服务器的硬盘通用,15,第五步:增配服务器网卡(选配),0202A0CM,NIC-Flex10-10GE-2P,Flex-
18、10 2*10GE,网卡,0202A0CN,NIC-FlexFabric-10GE-2P,FlexFabric 2*10GE,网卡,说明:,1,、此选配的网卡为刀片服务器的,Mezz,网卡(扩展网卡),,B390,有,2,个,Mezz,插槽,,B590,有,3,个,Mezz,插槽。,2,、,Flex-10,网卡和,FlexFabric,网卡的唯一区别在于,FlexFabric,比,Flex-10,网卡,多了,FCOE,功能。两者都可以做端口虚拟化,单端口最多可以虚拟为,4,个虚端口,3,、刀片服务器网卡通过中板与网络模块内联,无需配置光模块和连线,16,第六步:选择网络模块及光模块,1(,必配
19、总共,8,个网络模块插槽,),0202A0CH,VCM-Flex10-26P,Flex-10 26,端口刀片系统的,VC,模块,16,个,10GE,下行,+10,个,10GE,上行,0202A0CK,VCM-FC-24P,24,端口的,FC VC,模块,16,个,1/2/4/8Gb,下行,+8,个,1/2/4/8Gb,上行,0202A0CL,VCM-FlexFabric-10GE-24P,FlexFabric 10 24,端口刀片系统的,VC,模块,16,个,10GE,下行,+8,个,10GE,上行,其中上行口中有,4,个可以设置为,8Gb FC,端口,HP 8Gb Short Wave,B
20、Series SFP+1 Pack,8Gb SFP+FC,光模块,0231A0A6,SFP-XG-SX-MM850-A,SFP+,万兆模块,(850nm,300m,LC),说明:,1,、,Flex-10,模块和,FlexFabric,模块下行口都可以支持端口虚拟化,单个端口最,多可以虚拟成,4,个虚端口,2,、三种网络模块上行口都必须另配光模块,下行口通过中板与刀片服务器的,网卡内联,无需配置光模,3,、并排的模块之间可做堆叠,可内部互联堆叠,不用另配堆叠光模块,17,配置网络模块的类型和数量由刀片服务器的网卡决定:,如左图所示,刀片服务,器,1,的,LOM,网卡的网口,1(NIC1),必须
21、通过模块,1,与外界通信,网口,2(NIC2),必须通过模块,2,与外界通信,,Mezz1,网卡的网口,1,必须通过模块,3,与外界通信,依此类推。,因此要确定,网络模块的数量,就看需要使用几个网口,(,实网口,),;要确定网络模块的类型,就看服务器,网卡的类型。如果不配置,FCOE,功能,则,Flex-10,和,FlexFabric,模块都可以支持,Flex-10,和,FlexFabric,网卡;如需配置,FCOE,功能,则,Flex-10,模块支持,Flex-10,网卡,,FlexFabric,模块支持,FlexFabric,网卡和,Flex-10,网卡。,第六步:选择网络模块及光模块,2
22、必配,总共,8,个网络模块插槽,),18,第七步:增配冗余,OA,模块(选配,总共,2,个,OA,槽位),0202A0CG,OA-KVM-C8000,BLc8000,刀片机箱带,KVM,的管理模块,第八步:选择刀箱风扇(选配,总共,10,个风扇槽位),0202A0CF,FAN-C8000,BLc8000,刀片机箱风扇,注意:刀箱从左至右总共,8,个全高槽位,刀箱风扇配置依据刀箱槽位使用情况而定。,如果使用了,2,个槽位,至少配置,4,个风扇;如果使用了,34,个槽位,至少配置,6,个风扇;如果使用了,4,个以上的槽位,至少配置,8,个风扇;刀箱满配风扇为,10,个,19,第九步:增配电源模块(选配,总共,6,个电源槽位),0202A0CE,PWR-2400W-P,2400W,热插拔高级电源模块,注意:单片,B390,满配功耗小于,350W,,单片,B590,满配功耗小于,550W,,单台网络模块,功耗小于,120W,,刀箱风扇电源等满配功耗小于,710W,,通过简单计算即可得,出需要配置的电源数量。,20,