1、 设计中英文摘要 本工程为天津市一拟建多层旅馆。按使用功能将建筑分为八层的旅馆主楼和局部二层的商场。主楼标高28.2m,局部裙楼两层8.4m。总建筑面积10326.24m2。本建筑物防火等级二级,抗震设防烈度7度。 本工程结构设计采用框架结构,结构计算按横向框架承重分析。内力计算考虑以下四种荷载作用,即水平地震荷载作用下的内力,竖向恒载作用下的内力,重力荷载设计值作用下的内力及风载作用下的内力,。在进行截面抗震设计时,柱按偏压构件计算,为保证延性框架要“强剪弱弯,强柱弱梁,强节点弱构件强锚固的设计原则,且满足构造要求。 Design Abstract This engineerin
2、g is a hotel of many layers intending to set up in Tianjin City. According to the use function, the construct contents eight layer’s tall building and two layer’s short building. The high is 28.2 ms of Main floor and the partial floor elevation is 8.4 m. Total building area is 10326.24 m2. This buil
3、ding resistant fires is second class, and the anti-seismic garrison is seven point five degree. This engineering construction design adoption the frame construction, Being calculating the structure, the lateral structure be lacked as frame system and be analysis. construction calculation consider
4、of the action come from four loads, they are horizontal earthquake load, design value of gravity load and representative value of gravity load, and the other is wind load. Being underway the design of cross-section anti-seismic, we look the column as stubbornly pressed member to compute. In the intr
5、est of the assurance of the frame-work ability continue, we adhere to the design principle is “stranger column and weaker beam, stranger shear force and weaker bending, stranger joint stronger anchorage”. And the cross-section must to meet the demand of construction. 建筑设计说明部分 一、工程概况: 1、 工程名称:
6、某宾馆; 2、 工程位置:天津市; 3、 工程总面积:10326.24㎡,主楼8层,高28.2m,一、二层层高4.2m,标准层层高3.3m;裙楼共两层,高8.4m,层高4.2m; 4、 结构形式:现浇整体框架。 二、建筑物功能与特点: 该拟建的建筑位于天津市市内,设计内容:主楼为宾馆,裙楼为商场。此建筑占地面积 1、 平面设计 建筑朝向为南北向,平面布置满足长宽比小于5,采用纵向6.6m、横向4.5m、2.4m、6.0m的柱距,满足建筑开间模数和进深的要求。 2 该建筑立面为了满足采光和美观需求,设置了大面积的玻璃窗。外墙面根据《98J1——工程做法》选用面砖饰面,不同分隔区
7、采用不同的颜色区隔,以增强美 感。 3、防火 防火等级为二级,安全疏散距离满足房门至外部出口或封闭楼梯间最大距离小于35m,大房间设前后两个门,小房间设一个门,满足防火要求;室内消火栓设在走廊两侧,每层两侧及中间设3个消火栓,最大间距25m,满足间距50m的要求。 4、抗震 建筑的平立面布置规则,分为三个区(A、B、C),各区之间均设有净距300~500的抗震缝。建筑的质量分布和刚度变化均匀,楼层没有错层,满足抗震要求。 5、 屋面 屋面形式为平屋顶;平屋顶排水坡度为2%,排水坡度的形式为垫置坡度,排水方式为内排水。屋面做法采用《98J1——工程做法》中柔性防水,聚苯乙烯泡沫塑
8、料板保温层屋面。 三、设计资料 (一)、自然条件 1、工程地质条件:详见地质勘查报告。 2、抗震设防: 7 度 3、防火等级: 二级 4、建筑物类型: 丙类 5、基本风压: W0= 0.40 KN/m2,主导风向:西北风 6、基本雪压: S0= 0.50 KN/m2 7、冻土深度: -0.7 m 8、地下水位: 最低 9、气象条件: 年平均温度:12 oC 最高温度:39 oC 最低温度:-21 oC 年总降雨量:541.5 mm 日最大降雨量:115.5 mm 10、楼面活荷
9、 办公室:2.0 KN/m2;走道:2.0 KN/m2;餐厅:2.5 KN/m2。 (二)、工程做法 1、屋面做法——高聚物改性沥青卷材防水 ①4厚高聚物改性沥青卷材防水层(带砂、小片石,作为保护层) ②20厚1:3水泥砂浆层找平层 ③1:6水泥焦渣找2%坡,最薄处30厚 ④50厚聚苯乙烯泡沫塑料板保温层 ⑤钢筋混凝土基层 2、楼面做法 (1)房间、走道楼面——现制水磨石 ①12厚1:2.5水泥磨石楼面磨光打蜡 ②素水泥浆结合层一道 ③20厚1:3水泥砂浆找平层,上卧分隔条。 ④40厚C20细石混凝土垫层(后浇层) ⑤钢筋混凝土楼板 (2)卫生间楼面——铺地
10、砖 ①8厚地砖楼面,干水泥擦缝 ②撒素水泥面(洒适量清水) ③20厚1:4干硬性水泥砂浆结合层 ④60厚C20细石混凝土向地漏找平,最薄处30厚 ⑤聚氨酯三遍涂膜防水层厚1.5~1.8或用其他防水涂料防水层,防水层周边卷起高150 ⑥20厚1:3水泥砂浆找平层,四周抹小八字角 ⑦现浇钢筋混凝土楼板 (3)外墙面做法——面砖饰面 ①1:1水泥砂浆(细砂)勾缝 ②贴8厚面砖(在砖粘贴面上涂抹专用粘贴剂,然后粘贴) ③6厚1:0.2:2水泥石灰膏砂浆找平层 ④6厚1:1:6水泥石膏砂浆刮平扫毛 ⑤6厚1:0.5:4水泥石灰砂浆打底扫毛 ⑥刷一道加气混凝土界面处理剂 (4
11、内墙面做法——纸筋(麻刀)灰墙面 ①刷内墙涂料 ②2厚纸筋(麻刀)灰抹面 ③9厚1:3石灰膏砂浆 ④5厚1:3:9水泥石膏砂浆打底划出纹理 ⑤加气混凝土界面处理剂一道 (5)顶棚做法——铝合金条板吊顶 ①0.6厚铝合金条板面层 ②中龙骨U50×19×0.5中距为1000 ③大龙骨[60×30×1.5(吊顶附吊挂)中距为1000 ④Φ8螺栓吊杆,双向吊点(中距1000一个) ⑤钢筋混凝土板内预留Φ6铁环,双向中距1000 ⑥现浇钢筋混凝土板(板底用水加10%火碱清洗油腻) (6)散水做法:混凝土散水 ①50厚C15混凝土撒1:1水泥砂子,压实赶光 ②150厚3:7
12、灰土垫层 ③素土夯实向外坡4% (三)、门窗 1、 门选用标准图集中的木门,窗选用塑钢窗。 2、 门窗表见表1。 门窗表 表1 编号 洞口尺寸 开启方向 材料 樘数 备注 宽×高 C1 2400×2650 推拉窗 塑钢 52 单槽双玻,开启扇带纱扇 C2 1800×2650 推拉窗 塑钢 40 单槽双玻,开启扇带纱扇,卫生间窗装磨砂玻璃 C3 1500×1750 推拉窗 塑钢 4 单槽双
13、玻 C4 1800×1750 推拉窗 塑钢 220 单槽双玻,开启扇带纱扇,卫生间窗装磨砂玻璃 C5 1200×1750 推拉窗 塑钢 4 单槽双玻,开启扇带纱扇 C6 1500×1750 推拉窗 塑钢 12 单槽双玻,开启扇带纱扇 M1 4200×3600 弹簧门 玻璃门 2 M2 3000×3600 弹簧门 玻璃门 1 M3 1800×3600 平开门 夹板门 2 M4 900×2100 平开门 夹板门 240 M5 1500×2100 平开门 夹板门 4 M6 750×2100
14、 平开门 夹板门 22 结构设计计算书 一、 结构布置及结构计算简图的确定 1、 结构布置(B区) 结构平面布置如图1所示。 3~8层500×500 300×650 1~2层600×600 250×550 250×550 250×400 图1 结构平面布置图 2、确定梁柱截面尺寸: 主梁:h=(1/8~1/12)l=(1/8~1/12) ×6600=825mm~550mm 取h=650mm,b=300mm 连系梁:边跨(HG、FE)梁 h=550mm,b=250mm
15、 中跨(GF)梁 h=400mm,b=250mm 次梁: h=550mm,b=250mm 柱截面: 1~2层600mm×600mm 3~8层500 mm×500mm 现浇楼板厚100mm,满足h/l01≥ 1/50 3、计算简图的确定(见图2) 根据地质资料,确定基础顶面离室外地面为700mm,由此求得底层层高为5.5m。各梁柱构件的线刚度经计算后列于图2,其中在求梁截面惯性矩时考虑到现浇楼板的作用,边跨梁取I=1.5I0,中跨梁取I=2I0(I0为不考虑楼板翼缘作用的梁截面惯性矩)。 HG跨梁
16、 GF跨梁: FE跨梁: 3~8层柱: 2层柱: 首层柱: 注:图中数字为线刚度,单位:×10-4Em3 Ec=3.25×104N/mm2 Eb=3.00×104N/mm2 图2:结构计算简图 二、 荷载计算 1、 恒载计算 (1) 屋面框架梁线荷载标准值: 4厚高聚物改性沥青卷材防水层(三毡四油上铺小石子) 0.4 KN/ m2 20厚1:3水泥砂浆层找平层 0.02×20=0.4 KN/ m2 1:6水泥焦渣找2%坡,最薄处30厚
17、 KN/ m2 50厚聚苯乙烯泡沫塑料板保温层 0.05×0.5=0.025 KN/ m2 钢筋混凝土基层 0.1×25=2.5 KN/ m2 铝合金条板吊顶 0.12 KN/ m2 屋面恒载: 4.81 KN/m2 边跨(HG、FE跨)框架梁自重 0.25×0.55×25=3.44 KN/ m2 中跨框架梁自重
18、 0.25×0.4×25=2.5KN/ m2 粉刷 2×(0.4-0.1)×0.02×17=0.2 KN/ m2 因此,作用在顶层框架梁上的线荷载为:(图3) g8HG1= g8FE1=3.44KN/ m g8GF1= 2.5 KN/ m g8HG2= g8FE2=4.81×3.3=15.87 KN/ m g8FG2= 4.81×2.4=11.54KN/ m (2)楼面框架梁线荷载标准值 30厚水磨石地面(10mm面层,20mm水泥砂浆打底) 0.65KN/m2 40厚C20细石混凝土垫层
19、 0.04×25=1.0KN/ m2 100厚钢筋混凝土楼板 0.1×25=2.5 KN/ m2 铝合金条板吊顶 0.12 KN/ m2 楼面恒载 4.27 KN/ m2 3~7层框架梁 边跨(HG、FE跨)框架梁自重 0.25×0.55×25=3.44 KN/ m 边跨填充墙自重 0.19×(3.3-
20、0.65)×6.0=3.02 KN/ m 墙面粉刷 (3.3-0.65)×0.02×2×17=1.80 KN/ m 中跨框架梁自重 0.25×0.4×25=2.5KN/ m 梁侧粉刷 2×(0.4-0.1)×0.02×17=0.2 KN/ m 因此,作用在3~7层框架梁上的线荷载为(图3): gHG1= gFE1=3.44+3.02+1.80=8.26 KN/ m gGF1= 2.5 +0.2=2.7KN/ m gHG2= gFE2=4.27×3.3=14.
21、09KN/ m gFG2= 4.27×2.4=10.25KN/ m 2层框架梁 边跨填充墙自重 0.19×(4.2-0.65)×6.0=4.05 KN/ m2 墙面粉刷 (4.2-0.65)×0.02×2×17=2.41KN/ m2 因此,作用在2层框架梁上的线荷载为(图3): gHG1= gFE1=3.44+4.05+2.41=9.90 KN/ m gGF1 =2.7 KN/ m gHG2= gFE2=14.09 KN/ m gGF1= 10.25 KN/ m (3)、屋面框架节点集中荷载标准值 E轴框架梁自重
22、 0.30×0.65×6.6×25=32.18KN 粉刷 0.02×(0.65-0.10)×2×6.6×17=2.47KN 600高女儿墙自重 0.6×6.6×0.19×6.0=4.51KN 粉刷 0.6×0.02×2×6.6×17=2.69KN 框架梁传来屋面自重 KN 次梁自重
23、 0.25×0.55×6.0×25=20.61KN 作用在次梁上的屋面自重 KN 框架梁传来次梁自重 KN 顶层E轴节点集中荷载 G8E=32.18+2.47+4.51+2.69+26.19+44.83=112.87KN F轴框架梁自重及粉刷 32.18+2.47=34.65KN 框架梁传来屋面自重 KN 框架梁传来次梁自重 44.83KN 顶层F轴节点集中荷载 G8F=34.65+57
24、36+44.83=136.84KN G轴框架梁自重及粉刷 34.65KN 框架梁传来屋面自重 57.36KN 次梁自重 0.25×0.55×4.5×25=15.47KN 作用在次梁上的屋面自重 KN 框架梁传来次梁自重 KN 顶层G轴节点集中荷载 G8G=34.65+57.36+30.36=122.37KN H轴
25、框架梁自重及粉刷 34.65KN 女儿墙自重及粉刷 7.20KN 框架梁传来屋面自重 26.19KN 框架梁传来次梁自重 30.36KN 顶层H轴节点集中荷载 G8H=34.65+7.2+26.19+30.36=98.40KN (4)3~8层楼面框架节点集中荷载
26、标准值 E轴框架梁自重及粉刷 34.65KN 塑钢窗自重 2×1.8×1.75×0.45=2.84KN 窗下墙自重 0.29×0.9×(6.6-0.5)×6=9.55KN 内粉刷 0.02×0.9×(6.6-0.5)×17=1.87 KN 外贴面砖 0.08×0.9×6.1×19.8=8.70
27、KN 窗边墙自重 0.29×(6.6-0.5-2×1.8)×(3.3-1.55)×6=7.61KN 内粉刷 0.02(6.6-0.5-2×1.8)×(3.3-1.55)×17=1.49 KN 外贴面砖 0.08×(3.3-1.55)×2.5×19.8=6.93 KN 框架梁传来楼面自重 KN 次梁自重 0.25×0.55×6.0×25=20.61KN 作用在次梁上的墙自重
28、 0.19×(3.3-0.55)×5.5×6=17.24 KN 粉刷 2×0.02×(3.3-0.55)×5.5×17=10.29 KN 作用在次梁上的楼面自重 KN 框架梁传来次梁自重 KN 框架柱自重 0.5×0.5×3.3×25=20.63 KN 内粉刷 0.9×0.02×3.3×17=1.01 KN 外贴面砖
29、 0.08×0.5×3.3×19.8=2.61KN 3~8层E轴节点集中荷载 GE=34.65+2.84+9.55+1.87+8.70+7.61+1.49+6.93+23.25+54.72+20.63+1.01 +2.61=175.86KN F轴框架梁自重及粉刷 34.65KN 内纵墙自重 6.1×(3.3-0.65)×0.19×6.0=18.43 KN 粉刷 6.1×(3.3-
30、0.65)×2×0.02×17=10.99KN 扣除门洞重 -2.1×0.9×(0.19×6.0+2×0.02×17)×2=-6.88 KN 门重 2.1×0.9×0.2×2=0.76 KN 框架梁传来屋面自重 KN 次梁自重 20.61 KN 作用在次梁上墙的自重及粉刷 17.24+10.29=27.53 KN 作用在次梁上的楼面自重
31、 61.30 KN 框架梁传来次梁自重 KN 框架柱自重 20.63 KN 粉刷 1.6×0.02×3.3×17=1.80 KN 3~8层F轴节点集中荷载 GF=34.65+18.43+10.99-6.88+0.76+50.92+54.72+20.63+1.80=186.02 KN G轴框架梁自重及粉刷 34
32、65KN 内纵墙自重 18.43 KN 粉刷 10.99KN 扣除门洞重 -6.88 KN 门重 0.76 KN 框架梁传来屋面自重
33、 50.92KN 次梁自重 15.47 KN 作用在次梁上墙的自重及粉刷 0.19×(3.3-0.55)×4.0×6.0=12.54 KN 2×0.02×(3.3-0.55)×4.0×17=7.48 KN 作用在次梁上的楼面自重 KN 框架梁传来次梁自重 KN 框架
34、柱自重 20.63KN 粉刷 1.80 KN 3~8层G轴节点集中荷载 GG=34.65+18.43+10.99-6.88+0.76+50.92+37.83+20.63+1.80=169.13KN H轴框架梁自重及粉刷 34.65KN 墙体自重
35、 38.99 KN 框架梁传来楼面自重 23.25KN 框架梁传来次梁自重 37.83KN 框架柱自重 20.63 KN 粉刷加面砖 1.01+2.61=3.62KN 3~
36、8层H轴节点集中荷载 GH=34.65+38.99+23.25+37.83+20.63+3.62=158.97KN (5)2层楼面框架节点集中荷载标准值 E轴框架梁自重及粉刷 34.65KN 塑钢窗自重 2×1.8×2.65×0.45=4.29KN 窗下墙自重 0.29×0.9×(6.6-0.6)×6=9.40KN 内粉刷
37、 0.02×0.9×(6.6-0.6)×17=1.84 KN 外贴面砖 0.08×0.9×6.0×19.8=8.55 KN 窗边墙自重 0.29×(6.6-0.6-2×1.8)×(4.2-1.55) ×6=11.07KN 内粉刷 0.02×(6.6-0.6-2×1.8)×(4.2-1.55) ×17=2.16 KN 外贴面砖 0.08×(4.2-1.55)×2.3×19.8=9.65KN
38、 框架梁传来楼面自重 KN 次梁自重 0.25×0.55×6.0×25=20.61KN 作用在次梁上的墙自重 0.19×(4.2-0.55)×5.5×6=22.89 KN 粉刷 2×0.02×(4.2-0.55)×5.5×17=13.65 KN 作用在次梁上的楼面自重 61.30 KN 框架梁传来次梁自重 KN 框架柱自重
39、 0.6×0.6×4.2×25=37.80 KN 内粉刷 1.2×0.02×4.2×17=1.71 KN 外贴面砖 0.08×0.6×4.2×19.8=3.99KN 2层E轴节点集中荷载 GE=34.65+4.29+9.40+1.84+8.55+11.07+2.16+9.65+23.25+59.23+37.80+1.71 +3.99=207.59KN F轴框架梁自重及粉刷
40、 34.65KN 内纵墙自重 6.0×(4.2-0.65)×0.19×6.0=24.28 KN 粉刷 6.0×(4.2-0.65)×2×0.02×17=14.48KN 扣除门洞重 -6.88 KN 门重 0.76KN 框架梁传来屋面自重
41、 50.92KN 框架梁传来次梁自重 59.23KN 框架柱自重 37.80KN 粉刷 2×0.02×4.2×17=2.86 KN 2层F轴节点集中荷载 GF=34.65+24.28+14.48-6.88+0.76+50.92+59.23+37.80+2.86=218.10 KN G轴框架梁自重及粉刷
42、 34.65KN 内纵墙自重 24.28KN 粉刷 14.48KN 扣除门洞重 -6.88 KN 门重 0.76 KN 框架梁传来屋面自重
43、 50.92KN 次梁自重 15.47 KN 作用在次梁上墙的自重及粉刷 0.19×(4.2-0.55)×3.8×6.0=15.81KN 2×0.02×(4.2-0.55)×3.8×17=9.43KN 作用在次梁上的楼面自重 KN 框架梁传来次梁自重 KN 框架柱自重
44、 37.80KN 粉刷 2.86 KN 2层G轴节点集中荷载 GG=34.65+24.28+14.48-6.88+0.76+50.92+40.44+37.80+2.86=199.31 KN H轴框架梁自重及粉刷 34.65KN 墙体自重
45、 46.96 KN 框架梁传来楼面自重 23.25KN 框架梁传来次梁自重 40.44KN 框架柱自重 37.80 KN 粉刷及面砖 5.70 KN 3~8层H轴节点集中荷载 G8H=34.65+46.96+23.25+40.4
46、4+37.80+5.70=188.80KN (6)恒载作用下结构计算简图(图3) 2、楼面活荷载计算 楼面活荷载作用下结构计算简图如图4所示。图中各荷载计算如下: (1)、屋面框架梁线荷载标准值 p8HG= p8FE=0.5×3.3=1.65KN/ m p8GF=0.5×2.4=1.2 KN/ m (2)、楼面框架梁线荷载标准值 pHG= pFE=2.0×3.3=6.6KN/ m pGF=2.0×2.4=4.8 KN/ m 图4:活荷载作用下结构计算简图 图3:恒载作用下结构计算简图 (3)、屋面框架节点集中荷载标准值 E轴: 由框架梁传来的屋面荷载
47、 由框架梁传来次梁荷载 P8E=2.72+3.59=6.31KN F轴: 由框架梁传来的屋面荷载 由框架梁传来次梁荷载 3.59KN P8F=6.98+3.59=10.57KN G轴: 由框架梁传来的屋面荷载 6.98KN 由框架梁传来次梁荷载 P8G=6.98+2.35=9.33KN H轴: 由框架梁传来的屋面荷载
48、 2.72KN 由框架梁传来次梁荷载 2.35KN P8H=2.72+2.35=5.07KN (4)、楼面框架节点集中荷载标准值 E轴:由框架梁传来的屋面荷载 由框架梁传来次梁荷载 PE=10.88+14.35=25.23KN F轴:由框架梁传来的屋面荷载 由框架梁传来次梁荷载 14.35KN PF=27.93
49、14.35=42.28KN G轴:由框架梁传来的屋面荷载 27.93KN 由框架梁传来次梁荷载 PG=27.93+9.41=37.34KN H轴:由框架梁传来的屋面荷载 10.88KN 由框架梁传来次梁荷载 9.41KN PH=1
50、0.88+9.41=20.29KN 3、风荷载计算 风压标准值计算公式为 wk=βzμsμzw0 因结构高度H=29.3m,B=12.9,H/B=2.3>1.5,βz应按下式计算 βz= 对于框架结构T=(0.08~0.1)n, T=0.64~0.8,取T=0.7 则w0T2=0.40×0.72=0.2, 所以=1.25 地面粗糙程度为C类 =0.63 各层标高处βz见表2 对于矩形平面μs=1.3;μz可查荷载规范,当查得的μz<1.0时,取μz=1.0。将风荷载换算成作用于框架每层节点上的集中荷载,计算过程如表2所示。表中A为一榀框架各层节点的受风