1、 ~~ The Reinforced Earth Company 8614 Westwood Center Drive Suite 1100, Vienna, Virginia 22182 (703) 821-1175 - 21. NOTE TO CONTRACTORS ONLY THE FOLLOWING MATERIALS ARE SUPPLIED BY THE REINFORCED EARTH COMPANY: - PRECAST CONCRETE FACING PANELS - SOIL REINFORCEMENTS - BOLT SETS (FOR ATTA
2、CHING PANELS TO THE SOIL REINFORCEMENTS) - BEARING BLOCKS - RUBBER SHIMS - FILTER CLOTH AND ADHESIVE (FOR PANEL JOINTS ONLY) ANY OTHER MATERIALS CALLED FOR IN THE CONTRACT PLANS OR SPECIFICATIONS ARE TO BE SUPPLIED BY THE CONTRACTOR. ANY JOINT MATERIALS SHOWN AT THE INTERFACE OF PRECAST PANELS A
3、ND CASTIN-PLACE CONCRETE STRUCTURES ARE TO BE SUPPLIED BY THE ERECTION CONTRACTOR. ALL SANDBLASTING, PAINTING, SEALERS OR OTHER SPECIAL APPLIED COATINGS ARE ALSO SUPPLIED/INSTALLED BY THE CONTRACTOR IN THE FIELD FOLLOWING PANEL ERECTION. 22. THE REINFORCED EARTH COMPANY SUPPLIES PRECAST CONCRETE F
4、ACING PANELS AND ACCESSORIES TO BE USED IN CONJUNCTION WITH OTHER MATERIALS IN THE CONSTRUCTION OF THE REINFORCED EARTH RETAINING WALLS DETAILED HEREIN. THE CONSTRUCTION AND QUALITY CONTROL PROCEDURES MANUAL FURNISHED BY THE REINFORCED EARTH COMPANY IS INTENDED TO PROVIDE A GENERAL EXPLANATION OF TH
5、E SYSTEM. IT IS THE CONTRACTOR'S OBLIGATION TO DEVISE AND EXECUTE A PROJECT SPECIFIC ERECTION SEQUENCE, PANEL UNLOADING, HANDLING AND BRACING SYSTEM, AND FALL PROTECTION SYSTEM. THE BRACING SYSTEM SHOWN IN THE CONSTRUCTION AND QUALITY CONTROL PROCEDURES MANUAL IS GENERAL IN NATURE AND DOES NOT ACCOU
6、NT FOR PROJECT SPECIFIC CRITERIA. COMPLIANCE WITH THE GUIDELINES IN THIS MANUAL DOES NOT RELIEVE THE CONTRACTOR OF ITS RESPONSIBILITY TO ADHERE TO THE PROJECT PLANS, SPECIFICATIONS AND CONTRACT DOCUMENTS OR COMPLIANCE WITH ALL FALL PROTECTION, SAFETY, LAWS, STANDARDS AND PROCEDURES AT THE JOBSITE. C
7、ONTRACTORS SHOULD TAKE SPECIAL PRECAUTIONS TO PREVENT THE PANELS FROM SHIFTING OR FALLING DURING THE ERECTION PROCESS. 23. THE DESIGN CONTAINED ON THESE DRAWINGS IS BASED ON INFORMATION PROVIDED BY THE OWNER. ON THE BASIS OF THIS INFORMATION, THE REINFORCED EARTH COMPANY IS RESPONSIBLE FOR INTERNAL
8、 STABILITY OF THE STRUCTURE ONLY. EXTERNAL STABILITY DESIGN INCLUDING FOUNDATION AND SLOPE STABILITY IS THE RESPONSIBILITY OF OTHERS. 24. THESE DRAWINGS ARE CERTIFIED WITH RESPECT TO THE INTERNAL STABILITY OF REINFORCED EARTH STRUCTURES ONLY. 25. THIS DRAWING CONTAINS INFORMATION PROPRIETARY TO TH
9、E REINFORCED EARTH COMPANY, AND IS BEING FURNISHED FOR THE USE IN CONNECTION WITH FOOT PROJECTS ONLY, AND THE INFORMATION CONTAINED HEREIN IS NOT TO BE TRANSMITTED TO ANY OTHER ORGANIZATION UNLESS SPECIFICALLY AUTHORIZED IN WRITTING BY THE REINFORCED EARTH COMPANY. THE REINFORCED EARTH COMPANY IS E
10、XCLUSIVE LICENSEE IN THE UNITED STATES UNDER PATENTS ISSUED TO HENRY VIDAL, AND THE FURNISHING OF THIS DRAWING DOES NOT CONSTITUTE AN EXPRESSED OR IMPLIED LICENSE UNDER THE VIDAL PATENTS. THIS SYSTEM SHALL BE USED IN SLIGHTLY OR MODERATELY AGGRESSIVE ENVIRONMENTS ONLY. CRUCIFORM AND SQUARE PANELS
11、 DESIGN CRITERIA DESIGN IS BASED ON THE ASSUMPTION THAT THE MATERIAL WITHIN THE REINFORCED EARTH VOLUME, METHODS OF CONSTRUCTION AND QUALITY OF PREFABRICATED MATERIALS SHALL CONFORM TO THE CONTRACTING AGENCY'S TECHNICAL SPECIFICATIONS (SECTION 548) FOR REINFORCED EARTH WALLS 12. BACKFILL MA
12、TERIAL SHALL BE COMPACTED IN ACCORDANCE WITH SEC 548 TO A LEVEL OF 2"± ABOVE THE TIE STRIPS EMBEDDED IN THE PANELS. INSTALLATION OF SOIL REINFORCEMENTS SHALL BE PERMITTED ONLY AFTER PLACEMENT AND COMPACTION OF THE BACKFILL MATERIAL HAS REACHED THE REQUIRED LEVEL. 13. IF STRUCTURES IN EXCES
13、S OF 20' IN HEIGHT OCCUR, THE FINISHED GRADE 2. SOIL PARAMETERS: SEE WALL CONTROL DRAWINGS FOR SOIL CHARACTERISTICS OF FOUNDATION MATERIAL TO BE USED IN THE DESIGN OF THE WALL SYSTEM. THE CONTRACTOR SHALL PROVIDE SOIL DESIGN PARAMETERS FOR BACKFILL MATERIAL BASED ON THE ACTUAL SOIL CHARACTERIS
14、TICS UTILIZED AT IN FRONT OF THE WALL SHALL BE PLACED AND COMPACTED BEFORE WALL CONSTRUCTION EXCEEDS A HEIGHT OF 20'. FINISHED GRADE BACKFILL SHALL BE COMPACTED TO 95% OF AASHTO T-180 UNLESS OTHERWISE DIRECTED BY THE ENGINEER. THE SITE. THE VALUES OF FRICTION ANGLE (0), COHESION ( c ) AND
15、TOTAL UNIT WEIGHT ( y ) SHALL BE PROVIDED IN THE SHOP DRAWINGS. 14. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE LOCATION OF ANY GUARDRAIL POSTS BEHIND THE REINFORCED EARTH PANELS PRIOR TO PLACEMENT OF THE TOP LAYER OF SOIL REINFORCEMENTS. INDIVIDUAL REINFORCEMENTS MAY BE SKEWED UP TO
16、 15' TO AVOID THE POST LOCATIONS 3. THE MAXIMUM APPLIED BEARING PRESSURE AT THE FOUNDATION LEVEL IS AS SHOWN ON THE WALL ELEVATIONS FOR EACH DESIGN CASE. IT IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE THAT THIS APPLIED BEARING PRESSURE IS ALLOWABLE FOR THAT LOCATION. IF AUTHORIZED BY THE
17、 ENGINEER. ANY DAMAGE DONE TO THE SOIL REINFORCEMENTS DUE TO THE INSTALLATION OF THE GUARDRAIL SHALL BE REPAIRED BY THE CONTRACTOR AT THE CONTRACTOR'S EXPENSE. 15. IF EXISTING OR FUTURE STRUCTURES, PIPES, FOUNDATIONS OR GUARDRAIL 4. ANY UNSUITABLE FOUNDATION MATERIAL BELOW THE REINFORCED E
18、ARTH VOLUME, AS DETERMINED BY THE ENGINEER, SHALL BE EXCAVATED AND REPLACED WITH SUITABLE MATERIAL OR OTHERWISE STABILIZED AS DIRECTED BY THE ENGINEER. POSTS WHICH ARE WITHIN THE REINFORCED EARTH VOLUME INTERFERE WITH THE NORMAL PLACEMENT OF SOIL REINFORCEMENTS AND SPECIFIC DIRECTION HAS NOT
19、 BEEN PROVIDED ON THE PLANS, THE CONTRACTOR SHALL NOTIFY THE ENGINEER TO DETERMINE WHAT COURSE OF ACTION SHOULD BE TAKEN. 5. REINFORCING STRIPS FOR REINFORCED EARTH WALLS SHALL BE 1 31/32" WIDE AND 5/32" THICK, AND SHALL CONFORM TO THE PHYSICAL AND MECHANICAL PROPERTIES OF ASTM A-572 GRA
20、DE 65. GALVANIZATION SHALL BE APPLIED IN ACCORDANCE WITH ASTM A-123. 16. TOP PANELS BENEATH COPING SHALL HAVE #4 DOWELS PROTRUDING FROM THEIR TOP EDGE. 17. FOR OTHER INFORMATION PERTAINING TO WALL CONSTRUCTION PLEASE 6. HA LADDERS SHALL BE SUPPLIED BY THE REINFORCED EARTH COMPANY, AND S
21、HOP FABRICATED OF COLD DRAWN STEEL WIRE CONFORMING TO THE PHYSICAL AND MECHANICAL PROPERTIES OF ASTM A-82. ALL WELDING REFER TO THE REINFORCED EARTH CONSTRUCTION MANUAL. SHALL BE IN ACCORDANCE WITH ASTM A-185. GALVANIZING FOR PERMANENT WALL SYSTEMS SHALL CONFORM TO THE MINIMUM REQUIREMENTS
22、OF ASTM A-123 OR AASHTO M111 (2 OZ/SQ. FT.). HA LADDER REINFORCEMENTS MAY BE USED ONLY ON WALLS WITH HEIGHTS 20 FT OR LESS. 18. THE CONTRACTOR IS RESPONSIBLE FOR GRADUALLY DEFLECTING UPPER SOIL REINFORCEMENTS DOWNWARD TO AVOID CONFLICTS WITH PAVING AND SUBGRADE PREPARATION. THE CONTRACTOR'S AT
23、TENTION IS DIRECTED ESPECIALLY TO SITUATIONS WHERE ROADWAY SUPERELEVATION AND/OR SOIL MIXING ARE ANTICIPATED. 7. THE MINIMUM FACTORS OF SAFETY REQUIRED FOR DESIGN OVERTURNING = 2.0 SLIDING = 1.5 INTERNAL PULLOUT = 1.5 (ALLOWABLE DEFORMATION = 0.75 INCH) BEARING CAPACITY = 2.5 OVERALL STABILIT
24、Y = 1.5 STEEL SOIL REINFORCEMENT = 0.55Fy AT END OF DESIGN LIFE AND 0.50 Fu AT NET SECTION OF BOLTED CONNECTION MAXIMUM PULLOUT FACTOR f* (FOR SAND) = 1.5 (FOR LIMEROCK) = 2.0 WALL CONSTRUCTION 8. REINFORCED EARTH WALLS IN CURVES WILL FORM A SERIES OF SHORT CHORDS OF 4'-11" EACH TO MATCH DESIR
25、ED WALL ALIGNMENT. MATERIALS NOTES 19. NOMINAL SOIL REINFORCEMENT LENGTHS THE SOIL REINFORCEMENT LENGTHS SHOWN ON THE PLANS, MEASURED FROM BACK FACE OF PANEL, ARE THE NOMINAL LENGTHS REQUIRED BY CALCULATION. THE ACTUAL FABRICATED REINFORCEMENT LENGTHS ARE OFTEN LONGER (UP TO 6") DUE TO MANUFACTUR
26、ING TOLERANCES. THE REQUIRED HORIZONTAL LIMIT OF GRANULAR BACKFILL IS EQUAL TO THE NOMINAL SOIL REINFORCEMENT LENGTH. 20. PANEL FINISH THE PRECAST PANELS FOR THIS PROJECT SHALL HAVE A PLAIN STEEL FINISH UNLESS OTHERWISE SPECIFIED ON THE RETAINING WALL CONTROL PLANS. 9. FOR LOCATION AND ALIGNMENT
27、OF REINFORCED EARTH WALLS, SEE RETAINING WALL CONTROL PLANS. 10. IF MANHOLES AND DROP INLETS ARE PRESENT, THEY SHALL BE LOCATED AS SHOWN ON WALL ELEVATIONS. RETAINING WALL SYSTEMS THE REINFORCED EARTH COMPANY REINFORCED EARTH WALL STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION APPROVED BY Wi
28、lliam N. Nickas, P.E. SBIeS ctresOesign Engineer / of /6 11. IF PILES ARE LOCATED WITHIN THE REINFORCED EARTH VOLUME, THEY SHALL BE DRIVEN PRIOR TO CONSTRUCTION OF THE REINFORCED EARTH WALL UNLESS A METHOD TO PROTECT THE STRUCTURE, WHICH IS ACCEPTABLE TO THE ENGINEER AND THE REINFORCED EARTH COMP
29、ANY, AND IS PROPOSED AND APPROVED IN WRITING. DATE : 01-01-05 INTERIM STANDARD SHEET NOS. I - 16 OF 16 AREA REPLACEMENT OF INDEX NO. 5015 OF THE DESIGN STANDARDS BOOKLET DATED JANUARY 2004. REVisM No. 04 SxEET W. INDEX ND. 050/5 INTERIM STANDARD IN ENGLISH UNITS APPLICABLE TO DESIGN STANDAR
30、DS BOOKLET PUBLISHED IN ENGLISH UNITS. STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION RETAINING WALL SYSTEMS THE REINFORCED EARTH COMPANY REINFORCED EARTH WALL INTERIM STANDARD SHEET NOS. I - 16 OF 16 ARE A REPLACEMENT OF INDEX NO. 5015 OF THE DESIGN STANDARDS BOOKLET DATED JANUARY 2004
31、 4'-11" (TYPICAL) OF JOINT 1-JOINT JOINT S"EET W. INDEX ND. 050/5 174 2 of /6 REVisM No. FRONT FACE OF PANEL TIE STRIP L41.54 cq>rialll 4>ria54 0/WIN bi.N ! x..111 lle.111 lila &~ 111 111 O~ 111 rmlM ruin 4iiin 1~ .ilia fill 0,114 41q4 .... ~~.. 111°~~4~ ~1iriib11~ ~~riv~11" 1,)
32、 d b4 l~ I 1 I 1 1 HORIZONTAL WIDTH OF CLOTH 1'-6" ( TYP. ) LEVELING PAD J ' PANEL JOINT NOTE: STRIPS OF FILTER CLOTH SHALL BE PLACED ON BACK FACE OF PANEL, OVER PANEL JOINTS. FILTER CLOTH SHALL BE ADHERED TO BACK FACE OF PANELS USING AN ADHESIVE COMPOUND SUPPLIED BY THE REINFORCED EARTH CO
33、MPANY. ADHESIVE SHALL BE APPLIED TO PANEL THEN FILTER CLOTH (CARTHAGE MILLS TYPE FX-45HS OR EQUAL) SHALL BE APPLIED TO PANELS. FILTER CLOTH DETAIL PARTIAL ELEVATION - BACK FACE PANEL THICKNESS REINFORCEMENT DESIGNATION * PANEL REINFORCEMENT ( N2) MAXIMUM ALLOWABLE HORIZONTAL STRESS AT FAC
34、ING ( kPa ) 5 1/2" R4 0.44 VERTICAL 0.58 HORIZONTAL 1.19 R6 0.66 VERTICAL 0.78 HORIZONTAL 1.46 R7 1.18 VERTICAL 1.78 HORIZONTAL 2.58 * TOTAL AREA OF STEEL REQUIRED PER "TYPE A" PANEL. NOTES: 1. REINFORCING STEEL TO BE A615 GRADE 60. 2. 3/8" x 3/8" CHAMFER SHALL BE PROVIDED ON ALL
35、EXPOSED EDGES ( FRONT FACE ONLY ). 3. ALL PANEL TYPES AND OTHER RELATED ELEMENTS WILL BE DETAILED ON SHOP DRAWINGS. 4. ALL PANELS SHALL HAVE TWO LIFTING INSERTS OF ONE TON CAPACITY EACH. 5. PANEL DESIGN THICKNESS IS 5 1/2". THICKNESS OF CONCRETE MUST INCREASE TO ACCOMMODATE ANY ARCHITECTURAL SURF
36、ACE FINISH THAT MAY BE SPECIFIED. 6. ACTUAL PANEL REINFORCEMENT FOR ALL PANEL TYPES ON THIS PROJECT IS DESIGNATED ABOVE. R4 ILLUSTRATED FOR INFORMATION ONLY. SECTION C-C PANEL TYPE "A" WITH R4 REINFORCEMENT FRONT VIEW SECTION A-A 1 1/2" CONNECTION DETAIL TYPICAL PANEL LAYOUT PARTIAL ELEVATIO
37、N - FRONT FACE TYPICAL CHAMFER SECTION 1-1 THIS SYSTEM SHALL BE USED IN SLIGHTLY OR MODERATELY AGGRESSIVE ENVIRONMENTS ONLY CRUCIFORM AND SQUARE PANELS DATE : 01-01-05 INTERIM STANDARD IN ENGLISH UNITS APPLICABLE TO DESIGN STANDARDS BOOKLET PUBLISHED IN ENGLISH UNITS. APPROVED BY William N.
38、Nickas, P.E. S Wm Design Engireer JOINT EQ. - -3 1/8" B B B B B - I I L -CUT EDGE I I 1BBI B e CUT WIDTH ON ELEVATION AR-4-R4 1 B B B B C-2-R4 B-2-R4 B-3-R4 B-4-R4 CUT WIDTH ON ELEVATION 1 A-6-R4 AL-4-R4 A-3-R5 A-4-R4 A-5-R4 ~ _ r, r D-2-R4 D-3-R4
39、 B _J L B B B B B B B B B B B B B L C-3-R4 C-4-R4 D-4-R4 E-3-R4 E-4-R4 F-4-R4 F-5-R4 HJJ - HJ HII - HI - 7 3/8" r 8 B B B B B A A R A R R R A - I J L_ L_ _J r L 1888 f 1 B 8 8 C-4-R4 B B B B B B B B B F-8-R4 O-8-R4 SLO
40、PED TOP PANELS "H" PANEL USED FOR ILLUSTRATION ONLY. H-4-R4 H-5-R4 H-8-R4 HJ-4-R4 4'-11" STD. WIDTH HI-4-R4 B B B B B B B B B B B _J L_ _J rn I in A A R R _J _J B B B 8 B B B 8 B B B B B B B L B B B K-8-R4 K-5-R4 Q-4-R4 Q-5-R4 L-6-R4 L-7-R4
41、 B B P-7-R4 ALL PANELS ARE SHOWN BACK FACE VIEW P-6-R4 B TIE STRIP LOCATION CE TIE STRIP BLOCKOUT REQ'D. FOR PANELS THICKER THAN 5 1/2" (TYP.) R5 {HVERTICAL BARS A AS ORIZONTAL BA SRARE3 #4 AS OSHOWN R6 VERTICAL BARS ARE 6-#3 HORIZONTAL BARS ARE 4-#4 R7 VERTICAL BARS ARE 6-#4 HORIZONTAL
42、 BARS ARE 4-#6 N VARIES NOTE HEIGHT OF CORNER ELEMENTS AND SLIP JOINTS SHOULD MATCH WITH PANEL HEIGHT. CORNER ELEMENT SIZE VARIES WITH ANGLES 21/2" 1'-5" 2 1/2" N 5 j 1'-O" 15" 1'-10" SLIP JOINT SEE PANEL TYPE "A" WITH R4 REINFORCEMENT ON SHEET TITLED "PANEL DETAILS" FOR TYPICAL REINF
43、ORCEMENT SPACING THIS SYSTEM SHALL BE USED IN SLIGHTLY OR MODERATELY AGGRESSIVE ENVIRONMENTS ONLY CRUCIFORM PANELS STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION RETAINING WALL SYSTEMS THE REINFORCED EARTH COMPANY REINFORCED EARTH WALL DATE : 01-01-05 INTERIM STANDARD IN ENGLISH UNITS APPLICA
44、BLE TO DESIGN STANDARDS BOOKLET PUBLISHED IN ENGLISH UNITS. APPROVED BY William N. Nickas, P.E. INTERIM STANDARD SBIe Swcgrea Oeaign Engineer SHEET NOS. I - 16 OF 16 ARE A REPLACEMENT OF INDEX NO. 5015 OF THE DESIGN STANDARDS BOOKLET DATED JANUARY 2004. REVISION No. SKEET W. 10E% ND. 050/5
45、 04 3 of /6 SHEET W. INDEX W. 05015 04 4 o{l6 REvisM No. TOP OF PRECAST COPING. 10'-1 wlw„ . 80, A m.n. _ =.1 I PRECAST COPING PARTIAL ELEVATION C.I.P. CONC. COPING W/DITCH CLASS II CONC. (3400 PSI) THIS SYSTEM SHALL BE USED IN SLIGHTLY OR MODERATELY AGGRESSIVE ENVIRONME
46、NTS ONLY CRUCIFORM PANELS FOR ANY DESIRED SHORT PORTIONS OF C.I.P. CONC. COPING BETWEEN PRECAST CONC. COPING USE THIS SIMILAR C.I.P. CONC. SECTION. ALSO USE FOR VERTICAL COPING. C.I.P. COPING SECTION CLASS II CONC. (3400 PSI) STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION RETAINING WALL SYSTEMS
47、 THE REINFORCED EARTH COMPANY REINFORCED EARTH WALL INTERIM STANDARD SHEET NOS. I - 16 OF 16 ARE A REPLACEMENT OF INDEX NO. 5015 OF THE DESIGN STANDARDS BOOKLET DATED JANUARY 2004. #4 BAR 1118" O.C. MAX. AS REQUIRED #4 BAR @ 18" O.C. EACH FACE C.I.P. COPING - PARTIAL ELEVATION OTE: 1/2-INCH
48、 OPEN JOINTS IN COPING SHALL BE AT 6 PANEL INTERVALS AND COINCIDE APPROXIMATELY WITH CE OF PANEL JOINTS. REINFORCING STEEL SHALL BE STOPPED 2" SHORT OF EITHER SIDE OF THE JOINTS. CONSTRUCTION JOINTS IN BETWEEN THE OPEN JOINTS SHALL BE PROVIDED AT 2 PANELS INTERVALS. COPING ENCLOSURE DETAIL 2 1/2
49、" OPEN JOINT TOP OF LEVEL-UP CONCRETE INTERIM STANDARD IN ENGLISH UNITS APPLICABLE TO DESIGN STANDARDS BOOKLET PUBLISHED IN ENGLISH UNITS. DATE : 01-01-05 1'-4" 8 ONE TON SPREAD ANCHOR-2/UNIT CONTRACTOR TO FILL RECESS WITH NON-SHRINK GROUT AFTER PLACEMENT NOTE: ALL BARS ARE #4 AS SHOWN ON
50、SHOP DRAWINGS. STANDARD COPING UNIT IS 10'-0" LONG WITH SQUARE ENDS. ALL OTHER LENGTHS AND PIECES REQUIRING BEVELED ENDS SHALL BE FIELD CUT BY THE CONTRACTOR OR C.I.P. PER DETAIL LEFT. 3-#4'S, 2'-0" LONG DOWELS PER PANEL. CONTRACTOR TO TRIM DOWELS WHERE REQUIRED TO CLEAR TOP OF LEVELING CONCRETE FI






