1、 A-2008143-1 房 屋 安 全 鉴 定 报 告 Building Safety Appraisal Report项目卖力人Project Manager审 核 人Audited by批 准 人Approved by 签 发 机 构 Issuing Agency 发 文 日 期 年 月 日Issuing Date 判定陈诉包罗以下内容:1. 根本情况。2. 衡宇表面。3. 现场检测结果。4. 工程检测结果。5. 复核盘算结果。6. 衡宇损坏原因阐发。7. 判定结论及处置惩罚意见。8. 本判定陈诉共 5页。This appraisal report include the followi
2、ng contents:1、 General information.2、Overall conditions of the building.3、Results of site-testing.4、Results of engineering testing.5、Results of recomputation.6、Analysis of the causes of building damages.7、Conclusion of the appraisal and treatment recommendations.8、This appraisal report consists of 5
3、 pages in total.注:陈诉内容中4、5项不是每处衡宇判定都需要,应视实际产生而定。Note: Item 4 or 5 listed above is not required in all building appraisals and should be provided on a case-by-case basis.注 意 事 项1、判定结论依据危险衡宇判定尺度(JGJ12599)、修建抗震判定尺度(GB5002395)和有关技能范例提出。2、项目卖力人、审核人、批准人三级签字均应切合北京市衡宇宁静判定事情治理步伐的要求,签发机构应填写判定机构的全称,并加盖公章方为有效。3
4、、判定结论为宁静使用的,衡宇宁静判定陈诉自签发之日起一年内有效,当判定为危险衡宇或局部危险衡宇时,请按解危时限实时处置惩罚。4、一般情况本陈诉仅对查验时的衡宇现状卖力。5、本陈诉结论有异议时,请于判定陈诉签发之日起十五日内持本判定陈诉向北京市衡宇判定治理所书面申请复核判定。Notices1、The conclusion of this appraisal report is provided on the basis of the Standard of Dangerous Building Appraisal (JGJ125-99) 、Standard for Seismic Apprais
5、er of Buildings (GB50023-95), as well as other relevant technical codes.2、This report must be duly signed by the three levels of authority. Including the Project Manager 、the Appraiser and the Approver. incompliance with the requirements of the Administrative Measures on the Management of Building S
6、afety Appraisal in Beijing. The issuing agency shall present its name in full and attach an official stamp to its name in order to make this report effective.3、If the conclusion of the appraisal is “safe for use” , the Building Safety Appraisal Report will remain valid for a period of one year comme
7、ncing from the issuing date ;if the building has been appraised to be “dangerous” or “partially dangerous” ,such building must be treated within the timeframe set for the treatment of “dangerous buildings.4、In general , the appraiser of this report is only responsible for the conditions of the build
8、ing at time when the building is being appraised.5、If there any objection to the conclusion of this appraisal report ,a written application can be filed with Beijing Building Appraisal Administrative office for an audit of the appraisal within 15 days upon receipt of this appraisal report. 根本情况及判定结论
9、 p:1申请人(单元)联系人 电 话 所有权人(单元) 使用人(单元) 衡宇名称 结构类型 衡宇地点 修建面积 判定结论本判定仅针对云南省*档案馆馆舍结构。凭据检测结果,依据民用修建可靠性判定尺度GB 50292-1999、危险衡宇判定尺度JGJ125-99(2004年版)等范例评定阐发如下:1、该馆使用性切合GB 50292-1999范例中Css级衡宇要求,既该衡宇已经不能满足正常使用要求,应对衡宇维护结构进行翻修。2、该档案馆楼板结构荷载承载力远低于12KN/m2要求,其结构宁静性不能满足档案馆的使用要求,依据GB 50292-1999、JGJ125-99(2004年版)范例,该档案馆处于
10、D级衡宇状态整幢危险衡宇,不宜做为档案馆使用。3、该档案馆抗震横墙间距、圈梁设置、结构柱设置等大部门抗震步伐和墙体砖、砂浆的强度品级不切合修建抗震判定尺度GB50023-2009中云南地域8度抗震设防要求,应进行加固处置惩罚。4、发起对该档案馆进行落地翻建或选址重建。项目卖力人到场判定人员 年 月 日 房 屋 概 况 P:2衡宇名称衡宇地点设计单元施工单元修建年代年原用途现用途总 长 度(m)檐 高(m)层 数层一、衡宇表面现场检测、工程检测、复核盘算结果,衡宇损坏原因阐发,判定结论,处置惩罚意见。 P:3二、现场检测结果年 月 日 ,我单元对云南省*档案馆馆舍进行了现场查抄,结果如下:1、衡宇维护结构的使用性和适修性查抄情况。2、衡宇地基底子的查抄情况。3、衡宇主体结构的查抄情况。4、衡宇的抗震设防情况查抄。现场检测、工程检测、复核盘算结果,衡宇损坏原因阐发,判定结论,处置惩罚意见。 P:4三、衡宇损坏原因阐发和判定现场检测、工程检测、复核盘算结果,衡宇损坏原因阐发,判定结论,处置惩罚意见。 P:5