1、1/GE/October 5,2024超声波的概念与书语及超声波流量计测量的原理PT878液体超声波流量计的组成PT878液体超声波流量计安装考虑因素PT878液体超声波流量计的故障判断PT878液体超声波流量计的操作2/GE/October 5,2024超声波的概念与书语频率:次声波 0 to 20 Hz声波 20 Hz to 20 kHz(Human hearing)超声波 20 kHz超声波的概念超声波的概念3/GE/October 5,2024传感器工作原理 传感器电能 机械能机械能 电能压电晶体的变化每个传感器能发射和接受发射接收4/GE/October 5,2024超声波流量计原理
2、:时差法超声波流量计原理:时差法 传感器既发送信号又接收 信号V tup=超声波被流体减速 tdn=超声波被流体加速tuptdnttupdn tttupdn=-DtPc-Vsinup=tPc+Vsindn=VLP 声信号传播时间逆流传播,tup顺流传播,tdn5/GE/October 5,2024VLP声速 c=Ptavg,ttt2avg=dnup+Q=Velocity AreaQ=V A体积流量tt tttupdnupdn=-DtPc-VsintPc+Vsinupdn=流速 V C2L2 t超声波流量计原理:时差法超声波流量计原理:时差法6/GE/October 5,2024夹装式传感器 折
3、射原理 Snells Lawc1=传感器内传播速度c2=管壁的传播速度c3=流体内的传播速度S=传感器的间距c1 1c2 2 3c3LSW.T.Classic“clamp-on”approach7/GE/October 5,2024PT878液体超声波流量计的组成1主机传感器信号线充电器红外线转RS232测厚探头偶合剂仪器包8/GE/October 5,2024PT878液体超声波流量计的组成21.OKS传感器夹具2.CRS和CPT传感器夹具3.CF-LP传感器夹具9/GE/October 5,2024所配传感器的特性及用途传感器代码型号C-RS402C-RS401C-PT116CF-LP 2
4、3OKSSpecial(91)形状频率1.0 MHz0.5 MHz1.0 MHz4.0 MHz2.0 MHz发射角度42423559.5传播时间17.320.327.55.85传播速度248424842674.63328使用温度-40 to 150 C-40 to 150 C-20 to 210C-40 to 230C-200 to 360 C10/GE/October 5,2024传感器选用原则1.温度要求.2.信号要求.导声较差的介质和大的管道选择低频探头.3.精度要求.频率越高精度越高.2寸以下一般用CF-LP探头.11/GE/October 5,2024管道要求1.直管段要求:前10后
5、5.即在传感器安装位置前10倍直径长度和后5倍的直径长度无弯头,阀门等引起流体扰动的装置.2.准确测量管经外径周长或直径.3.确定管道材质和壁厚及接触温度.4.确定是否有内衬及种类和厚度.12/GE/October 5,2024介质要求1.已列出的介质直接选择2.未列出的介质需输入声速或选择跟踪窗口测试3.确定声速的目的是在窗口中央将信号检出.END OF TRANSMITGOOD SNRWINDOW13/GE/October 5,2024安装方式1.根据管道大小和信号强度选择安装方式A.单声程:大管道和复杂应用B:双声程:首选方式,安装简单.C:多声程:小管道,信号特强.安装位置:水平管道3
6、点和9点位置垂直管道必须是介质向上流14/GE/October 5,2024校准1.标定后输入校验系数2.雷诺数修正.Re=雷诺数#V=流体流速ID=内径=运动粘度(ft2/sec or m2/sec)15/GE/October 5,2024进行信号诊断介质充满管道后需检测的参数和信号流向是否正常信号强度SSup;SSdn 声速SNSP波型等根据诊断参数调整有关输入参数得到准确结果16/GE/October 5,2024进行信号诊断信号强度SSup;SSdn 50-55偏低可能不稳定55-60 低一点,可以接受60-65 好65-75 非常好75-99 信号饱和,分辨率可能降低0.电缆线开路1
7、00.控制器故障声速SNSP应在合理范围内.如水1500m/s左右17/GE/October 5,2024进行信号诊断错误代码E0:无错误E1:信号太低E2:声速错误E3:流速超出范围E4:信号质量太差E5:流速变化太大18/GE/October 5,2024FeaturesLarge,Backlit LCDSimplified KeypadGraphical User Interface(GUI)Faster Update RateImproved Peak DetectionLarger,more powerful Data LoggerXML-format Site FilesFlash
8、 memory Simple UpgradesPT878 Ultrasonic FlowmeterIrDA -compatible wireless data transferUp to 11 hours run time per charge19/GE/October 5,2024LCD Display240 x 200 resolutionRoom for 1 to 4 measurementsLarge signal waveform displaysWhite EL BacklightPT878 Ultrasonic Flowmeter20/GE/October 5,2024LCD D
9、isplay240 x 200 resolutionRoom for 1 to 4 measurementsLarge signal waveform displaysWhite EL BacklightPT878 Ultrasonic Flowmeter21/GE/October 5,2024KeypadRubberized keysClick actionSimple universal layoutSoft Function KeysPT878 Ultrasonic Flowmeter22/GE/October 5,2024Graphical UserInterface(GUI)Keep
10、s related information togetherAll choices visible at the same timePT878 Ultrasonic Flowmeter23/GE/October 5,2024GUI ControlsMenusRelated items grouped togetherUse to move through choicesUse to change menusPress Enter to selectPT878 Ultrasonic Flowmeter24/GE/October 5,2024GUI ControlsTabsQuick access
11、 to related formsUse to select formPress Enter to open the formPT878 Ultrasonic Flowmeter25/GE/October 5,2024GUI ControlsButtonsSelects between mutually exclusive choicesUse to select buttonPress Enter to activatePT878 Ultrasonic Flowmeter26/GE/October 5,2024PT878 Ultrasonic FlowmeterGUI ControlsLis
12、tsChoose from all applicable settingsUse to move one itemUse to scroll the list27/GE/October 5,2024PT878 Ultrasonic FlowmeterGUI ControlsNumeric EntryPress Enter to begin entering digitsPress to erase a digitPress Esc to cancel and restore original valuePress Enter to accept the new valueValues can
13、be entered or displayed in either Metric or English units without having to change meter defaults28/GE/October 5,2024PT878 Ultrasonic FlowmeterGUI ControlsCheck BoxesUsed to turn an option:On Off Press Enter to toggle29/GE/October 5,2024GUI ControlsFunction KeysChange according to form or menu activ
14、ePress F1,F2,or F3 to selectPT878 Ultrasonic Flowmeter30/GE/October 5,2024GUI ControlsLocale-SpecificChange date,time,and decimal formats for local custom:MM/DD/YYYYDD-MM-YYYYYYYY-MM-DD11:59 PM23:59123.45123,45PT878 Ultrasonic Flowmeter31/GE/October 5,2024Data Logger1 Megabyte storage 100,000 record
15、sFrom 1 to 12 items per logMultiple logs can run simultaneouslyLog interval from 1 second to 99 minutesProgrammable Start and End Date/TimeCyclic LogsError logsPT878 Ultrasonic Flowmeter32/GE/October 5,2024Flash MemoryInstall new program in minutes over IRNo EPROMs to changePT878 Ultrasonic Flowmete
16、r33/GE/October 5,2024IrDA -Compatible WirelessCommunicationsInfrared data transferUp to 115KbpsUp to 1 meter rangeDrag&Drop file transfersAutomaticNo settingsNo cable adapters requiredPT878 Ultrasonic Flowmeter34/GE/October 5,2024BatteryNiMH rechargeable9 to11 hour run time(longer than NiCd)6 hour r
17、echargeNone of the memory problems associated with NiCdFewer charge cycles than NiCdNiCd performs better in cold NiCd or disposable AA alkaline cells can be used instead of NiMHPT878 Ultrasonic Flowmeter35/GE/October 5,2024BatteryContinuous battery level gaugeSimple icon indicates chargeUniversal ch
18、arger 100-250VACPT878 Ultrasonic Flowmeter36/GE/October 5,2024BatteryRun time up to 11 hours,depending on features selected.Run time is reduced by:Prolonged use of the backlightLoop-powered 4-20mA transmittersHigh resistance loads on 4-20mA outputRun time is increased by:Using Sleep modePT878 Ultras
19、onic Flowmeter37/GE/October 5,2024PT878 Ultrasonic FlowmeterEnvironmentalMeets IP67 ratingWithstands submersion in waterDurable polymer bootPrevents damage if droppedIntegrated wire stand38/GE/October 5,2024PT878 Ultrasonic FlowmeterMeter SetupA.Select UnitsB.Select TransducerC.Select PipeD.Select L
20、iningE.Select FluidF.Adjust PathG.Correction FactorsH.Save to a Site39/GE/October 5,2024PT878 Ultrasonic FlowmeterSelect UnitsThe PT878 can default to either Metric or English units.From the Meter menu,select Units.Press OK to use the new settings.40/GE/October 5,2024PT878 Ultrasonic FlowmeterSelect
21、 TransducerSelect Wetted or Clamp-onChoose Transducer from ListList only shows applicable transducersAll parameters filled in automaticallyChoose SPECIAL to enter customer parametersAllows each parameter to be specified41/GE/October 5,2024PT878 Ultrasonic FlowmeterSelect PipeSelect Pipe Material fro
22、m ListPipe Sound Speed automatically filled inSelect OTHER for unlisted materialEnter Sound SpeedEnter DimensionsOuter Diameter(OD)or Circumference(ODxPI)Wall thickness42/GE/October 5,2024PT878 Ultrasonic FlowmeterSelect PipeIf pipe material has a schedule,ID can be used to automatically enter dimen
23、sions.Uses ANSI(English)or DIN(metric)schedule.Schedule Materials:Stainless SteelCarbon SteelCast IronPVCCPVC43/GE/October 5,2024PT878 Ultrasonic FlowmeterSelect LiningChoose lining material from list,or Other to specifyLining option is not available when using Wetted transducers44/GE/October 5,2024
24、PT878 Ultrasonic FlowmeterSelect FluidEnable/Disable Tracking WindowsUse for fluids with unknown or highly variable sound speedSpecify minimum and maximum soundspeedChoose fluid from list or Other for unlisted fluidIf fluid not listed,specify the nominal soundspeed only45/GE/October 5,2024PT878 Ultr
25、asonic FlowmeterSelect FluidFor Energy applications with water as fluid,specify the%Glycol concentration46/GE/October 5,2024Adjust PathFor clamp-on,Path length P and Axial length L are automatically calculated.Select the number of traverses.Spacing is automatically recalculated.Spacing can be change
26、d by entering a new value.PT878 Ultrasonic Flowmeter47/GE/October 5,2024Finish UpYour changes will not take effect until you:Press OK to keep all changesPress CANCEL to discard all changesPT878 Ultrasonic Flowmeter48/GE/October 5,2024Correction FactorsReynolds CorrectionUse a single value for Kineti
27、c Viscosity(K/V).Table option is not availablePT878 Ultrasonic Flowmeter49/GE/October 5,2024Correction FactorsK-Factor CorrectionUse a single value for K-Factor multiplierUse a Table to relate K-Factor to another measure.Only Velocity can be used to interpolate the K-Factor.PT878 Ultrasonic Flowmete
28、r50/GE/October 5,2024Save to a Site FileTo keep the new settings,you must save them to a Site File:Choose Save Now to replace the settings in the current site.Choose Manager to create a new site.PT878 Ultrasonic Flowmeter51/GE/October 5,2024Site ManagerUse the Site Manager to:Save settings to a new
29、site.Use and existing site.Delete sites.Rename sites.Print or Transfer sites.PT878 Ultrasonic Flowmeter52/GE/October 5,2024Site ManagerOpen the Site Manager menu by pressing Menu,Enter.Choose Save As to name the site and store it.PT878 Ultrasonic Flowmeter53/GE/October 5,2024Site ManagerEnter a file
30、 name of up to 8 characters:Use arrows to move around the grid.Press Enter to select the character.Use Delete to erase a character.Press OK when done.Hint:A descriptive Site Message can be entered from the Site MenuPT878 Ultrasonic Flowmeter54/GE/October 5,2024Site FilesUp to 32 sites stored in PT87
31、8Can be transferred to/from PC for unlimited capacitySoftware versions need to match to ensure compatibilityXML*FormatFiles print as shown hereSome outputs are codedSet-ups are best viewed through a meterSite Files should not be edited with a PC or laptop*eXtensible Markup Language PT878 Ultrasonic
32、Flowmeter55/GE/October 5,2024DiagnosticsDisplay all Diagnostics SimultaneouslySelect“Diagnostics”in the Service MenuPress EnterPT878 Ultrasonic Flowmeter56/GE/October 5,2024DiagnosticsAll Diagnostics viewed simultaneouslyEasy and efficient analysisPT878 Ultrasonic Flowmeter57/GE/October 5,2024NoteTh
33、e above presentation reflects PT878 Instrument Program INST.001.J and ECO 4958New functionality and capabilitiesMinor changes in menusAll meters with serial#1294 and above will include these modificationsMeters with serial#1293 and lower can be upgraded(consult the factory)PT878 Ultrasonic Flowmeter
©2010-2024 宁波自信网络信息技术有限公司 版权所有
客服电话:4008-655-100 投诉/维权电话:4009-655-100