1、资料内容仅供您学习参考,如有不当或者侵权,请联系改正或者删除。七 风荷载内力计算基本风压w0=0.4kN/m2, 地面粗糙度为B类。本章计算以左风为例。(一) 风荷载计算wk=zszw0, 建筑物高度30m, 故z=1.0迎风时s1=+0.8, 背风时s2=-0.5, 则s=0.8+0.5=1.3计算过程见下表楼层高度H(m)zwkA(m2)P(kN)五19.21.230.6421.8413.98四15.61.150.628.0816.85三12.01.060.5528.0815.44二8.41.00.5228.0814.60一4.81.00.5232.7617.04计算简图( 单位: kN)
2、 (二) 内力计算1抗侧刚度和反弯点高度确定计算过程见下表楼层KD(104kN/m)y0Iy12y23y3yhh-yh边柱五1.190.373.080.3610101.302.30四1.190.373.080.411010101.482.12三1.190.373.080.461010101.661.94二1.190.373.080.501010101.801.80一1.270.541.940.6200.6803.292.01中柱五2.390.544.50.4210101.512.09四2.390.544.50.451010101.621.98三2.390.544.50.501010101.80
3、1.80二2.390.544.50.501010101.801.80一2.550.672.410.5500.6802.922.382剪力在各层分配( 单位: kN) , VP5=13.98V5=2.84V5=4.15VP4=30.83V4=6.27V4=9.15VP3=46.27V3=9.41V3=13.73VP2=60.87V2=12.38V2=18.06VP1=77.91V1=17.39V1=21.573柱端弯矩计算( 单位: kNm) 6.538.673.696.2713.2919.129.2814.8218.2624.7115.6224.7122.2832.5122.2832.5134.9551.3457.2162.984风荷载作用下的内力图M图( 单位: kNm) V NV, N图( 单位: kN) 5梁端柱边弯矩( 单位: kNm) 6.083.863.4915.7511.3910.2225.5717.6815.9035.1425.6923.0252.7637.2233.03