1、DC GENERATION SYSTEM-INTRODUCTION Purpose The DC generation system makes a nominal 28v dc for airplane systems. General The DC generation system has these components: - Battery - Battery charger - Transformer rectifier units (3). DC GENERATION SYSTEM - GENERAL DESCRIPTION General Descri
2、ption The DC generation system supplies a nominal 28v dc to different loads. The power source for the DC system is usually the AC system. The battery supplies power if the AC system is not available. Transformer Rectifier Units To create DC power from the normal AC source, the DC system uses tr
3、ansformer-rectifier units (TRUs). The three TRUs take 115v ac, decrease the voltage (transforms), and rectify it to a nominal 28v dc. Battery Chargers The main battery charger and auxiliary battery charger give a DC voltage output to charge their respective battery. Each charger operates like a
4、TRU after the battery gets to full charge. The main battery charger sends a constant DC voltage to the battery and the hot and switched hot battery buses. The auxiliary battery and auxiliary battery charger power DC buses only during non-normal conditions. See the standby power system section for mo
5、re information. (AMM PART I 24-34) Batteries Each battery is a 48 ampere-hour, nominal 24v dc power source. The main battery supplies power for APU starting and is a standby power source if all other power supplies do not operate. The auxiliary battery helps the main battery supply standby power
6、 only. Control and Protection The standby power control unit (SPCU), the battery switch, and the standby power switch give primary control of the DC system. The battery switch and the standby power switch give manual control of power to some DC buses. The SPCU gives automatic control and protec
7、tion of DC buses. It uses inputs from the flight compartment and system monitoring to control DC power sources and distribution. Power Distribution The DC power distribution system is in the power distribution panels (PDPs) and in the SPCU. DC GENERATION SYSTEM - MAIN BATTERY CHARGER AND
8、 AUXILIARY BATTERY CHARGER Purpose The main battery charger has these two functions: - Keeps main battery at maximum charge - Supplies DC power to the battery buses. The auxiliary battery charger keeps the auxiliary battery at maximum charge. General Description Both battery chargers have t
9、he same part number. Each battery charger has these two basic modes of operation: - Battery charge mode (constant current) - Transformer rectifier mode (constant voltage). Each battery charger supplies constant current, variable voltage power in the battery charge mode. The battery charger overch
10、arges the battery. The battery charger logic calculates the amount of overcharge. The total charge time is less than 75 minutes. In the transformer rectifier (TR) mode, the main battery charger supplies constant voltage DC power to the hot battery bus and the switched hot battery bus. The main bat
11、tery also receives a small trickle charge to help keep it at maximum charge. The auxiliary battery charger does not supply power to the DC buses in either mode. However, the auxiliary battery receives a small trickle charge when the auxiliary battery charger is in the TR mode. The front face of ea
12、ch battery charger has two green status lights (LED). One light is for the battery charger and the other is for the battery. These lights are on when the battery and battery charger are in operation. Location The main battery charger is on the E2 rack. The auxiliary battery charger is on the E3
13、rack. Functional Description Each battery charger takes three-phase, 115v ac power and changes it to DC power. Usually, each battery charger is in the transformer rectifier mode. The battery chargers supply a constant voltage output in this mode. Each charger can supply up to 65 amps in this mod
14、e. A battery charger goes to the charge mode when its battery voltage is less than 23v dc. In this mode, the charger supplies constant current power. The output voltage is variable. During the charge, the battery voltage rises until the voltage gets to the inflection point. The charger logic uses t
15、he battery temperature at the start of charging to calculate the inflection point. The charger logic then calculates the length of the overcharge period. After the overcharge period, the charger goes into a transformer rectifier mode with a constant 27.5v dc output. The battery gets a trickle charg
16、e in this mode. The battery charger goes into the charge mode again if any of these occur: - Battery charger input power is off for more than 1 second. - Battery voltage is less than 23 volts. You use the electrical meters, battery, and galley power module to monitor the operation of each batter
17、y charger. The main battery charger is in the charge mode when you see a positive DC AMPS indication while the DC meter selector in the BAT position. Use the AUX BAT position to monitor the auxiliary battery charger. The main battery charger cannot go into the charge mode during any of these condit
18、ions: - Fueling station door open - APU start - Standby power switch (P5-5) in the BAT position - Standby power switch (P5-5) in the AUTO position, battery switch ON, and DC BUS 1 and AC TRANSFER BUS1 do not have power - Main battery overheat. The auxiliary battery charger cannot go into the c
19、harge mode during any of these conditions: - Standby power switch (P5-5) in the BAT position - Standby power switch (P5-5) in the AUTO position, battery switch ON and DC BUS 1 and AC TRANSFER BUS 1 do not have power. - Auxiliary battery overheat. Status Lights Both status lights are usually o
20、n when the battery charger has input power. A malfunction with any of these components makes one or both status lights go off: - Battery charger - Battery - Connection wiring. Both status lights are off if any of these conditions are true: - Input power to the battery charger goes away - Input
21、 voltage to the battery charger is less than 94v ac for more than 0.5 seconds. The battery charger status light is on and the battery status light is off if any of these conditions are true: - Battery charger senses a loss of connection to the battery - Battery overheat - Battery temperature sen
22、sor open or shorted - Battery not charged in time limits - Battery voltage less than lower limits. The battery charger status light is off and the battery status light is on when there is an internal battery charger failure. The battery charger fail maintenance message also shows on P5-13 BITE.
23、 DC GENERATION SYSTEM-BATTERY CHARGER-FUNCTIONAL DESCRIPTION Functional Description The battery charger takes 3-phase, 115v ac power and changes it to dc power. Usually, the battery charger is in the transformer rectifier mode. The battery charger supplies a constant voltage output in this mode
24、 The charger can supply up to 65 amps in this mode. The battery charger goes to the charge mode when the battery voltage goes below 23v dc. In this mode, the charger supplies constant current power. The output voltage is variable, the current output is 50 amps. During the charge, the battery volta
25、ge increases until the voltage gets to the inflection point. The charger logic uses the battery temperature at the start of charge to calculate the inflection point. The charger logic then calculates the length of the overcharge period. After the overcharge period, the charger goes into a transform
26、er rectifier mode with a constant 27.5v dc output. The battery gets a trickle charge in this mode. The battery charger goes into the charge mode again if any of these occur: - Battery charger input power is off for more than 1 second - Battery voltage goes below 23 volts. You use the electrical
27、meters, battery and galley power module to monitor the operation of the battery charger. The battery charger is in the charge mode when you see a positive DC AMPS indication when the DC meter selector in the BAT position. The battery charger cannot go into the charge mode during any of these condi
28、tions: - Fueling station door open - APU start - Standby power switch (P5-5) to the BAT position - Standby power switch (P5-5) to the AUTO position, battery switch ON, and DC BUS 1 and AC TRANSFER BUS 1 do not have power - Battery overheat. DC GENERATION SYSTEM - MAIN BATTERY AND AUXILIARY
29、 BATTERY Purpose The main battery has these functions: - Supply power to critical airplane systems (AC and DC standby buses) if the normal power sources are not available - Backup power supply for the AC system control and protection - Power supply for APU start. The auxiliary battery helps th
30、e main battery supply power to the critical airplane systems (AC and DC standby buses). Location The batteries are in the EE compartment, under the E3 rack. The auxiliary battery is forward of the main battery. You remove an access panel in the forward cargo compartment to get access to the batt
31、eries. You must remove the main battery before you can remove the auxiliary battery. General Description Each battery is a 20 cell nickel-cadmium battery with a 48 amp-hour capacity. With full charge, the batteries supply a minimum of 60 minutes of standby AC and DC power. Each battery has an i
32、nternal thermal sensor. The battery's charger uses this sensor to measure internal battery temperature. See the MAIN BATTERY CHARGER AND AUXILIARY BATTERY CHARGER page in this section for more information. Indication You can see the output of each battery on the electrical meters, battery and
33、galley power module on the P5 forward overhead panel. You see the voltage and current output of a battery with the DC meter selector in the BAT position or AUX BAT position. If the battery's charger has power, you see the output voltage of the battery or its battery charger, whichever is more. The
34、amber BAT DISCHARGElight comes on when any one of these output conditions are true for either battery: - Current draw is more than 5 amps for 95 seconds - Current draw is more than 15 amps for 25 seconds - Current draw is more than 100 amps for 1.2 seconds. Master caution and the ELEC annunciato
35、r usually come on with the BAT DISCHARGE light. The light goes out when the output current goes below the limit for more than 1 second. Master caution and the ELEC annunciator do not come on during a DC power APU start. Training Information Point You remove a battery from the airplane before you
36、 do a battery inspection or servicing. DC GENERATION SYSTEM - DUAL BATTERY REMOTE CONTROL CIRCUIT BREAKER Purpose The dual battery remote control circuit breaker (RCCB) puts the output of these in parallel: - Auxiliary battery - Auxiliary battery charger - Main battery - Main battery ch
37、arger. Location The RCCB is inside the J9 junction box. J9 is in the EE compartment, in front of the E2 rack. General Description The RCCB is normally open and closes when the SPCU signals it to close. This lets the 28v dc battery bus bar receive power from the main and auxiliary batteries a
38、t the same time. DC GENERATION SYSTEM - TRANSFORMER RECTIFIER UNIT (TRU) Purpose The transformer rectifier units (TRU) change three-phase nominal 115v ac, 400 hz input power into 28v dc to supply the main DC system loads. General Description The DC generation system has three TRUs. Each TRU
39、 can supply a continuous output load of 75 amps, with forced air cooling. The TRUs can supply 50 amps, with convection cooling. There are no external controls to the TRUs. The TRUs are the same part number. Location The TRUs are in the EE compartment. TRU 1 is on the E2 rack. TRU 2 and TRU 3 ar
40、e on the E4 rack. Indication You may monitor output power for each TRU from the P5-13. You can use the DC meter selector to select the TRU. TRU output voltage and amperes show in the alphanumeric display. The amber TR UNIT light comes to show a TRU failure. The light comes on for any of these
41、conditions: - Any TRU fails on the ground - TRU 1 fails in flight - TRU 2 and TRU 3 fail in flight. DC GENERATION SYSTEM-BATTERY BUSES-FUNCTIONAL DESCRIPTION Hot Battery Bus Power The hot battery bus receives DC power from the battery through a 28VDC bat bus bar in the J9 battery shield.Ther
42、e is a circuit breaker on the SPCU that permits power to the bus. The 28v dc battery bus bar receives DC power from the main battery or the main battery charger under normal power conditions. On standby power the 28v dc battery bus bar receives power from the main battery and the auxiliary battery.
43、 Switched Hot Battery Bus Power The switched hot battery bus receives DC power from the 28v dc battery bus bar through a circuit breaker on the SPCU and relay K8 in the SPCU. To get power to the switched hot battery bus, the battery switch must be ON. When the battery switch is ON, K8 SW HOT BA
44、T BUS RLY closes and gives dc power to the bus. With the forward airstair option, the K8 relay closes when the airstair handle is put in the standby position. The K8 relay gives DC power from the 28v dc battery bus bar to the SPCU power supply. Battery Bus Power The battery bus receives power
45、 from the 28v dc battery bus bar or TRU 3. The BAT BUS NORM RLY (K2) is closed and gives DC power from TRU3 to the battery bus when all of these conditions are true: - BATTERY SW ON - STANDBY POWER SW not in BAT position - TRU 3 gets more than 18v dc for more than 0.15 seconds. - When the K2 re
46、lay is closed, the BAT BUS ALT RLY(K1) must be opened. The K1 BAT BUS ALT RLY is closed and gives power to the BATTERY BUS during these conditions: - Battery switch is ON and TRU 3 does not have power (less than 18v dc) for more than 0.1 seconds or - STANDBY POWER SWITCH is in the BAT position.
47、直流电系统-介绍 目的 直流电系统产生28 伏直流供飞机系统。 概况 直流电系统有下列部件: -电瓶 -电瓶充电器 -变压整流器组件(3 ) 直流电系统-概况介绍 概况介绍 直流电系统给不同的负载提供正常28 伏直流电。直流系统的电源通常是交流系统。如果交流系统不适用,电瓶提供电源。 变压整流器组件 为从正常的交流电源产生直流电,直流系统使用变压整流器组件(TRU)。三个TRU将115 伏交流,降压(变压),并整流到正常28直流。 电瓶充电器 主电瓶充电器和辅助电瓶充电器产生直流电输出,并给相应电瓶充电。在电瓶得到完全充电后
48、每个充电器可当TRU使用。主电瓶充电器给电瓶和热电瓶及转换热电瓶汇流条提供正常直流电压。只有在非正常情况下,辅助电瓶和辅助电瓶充电器给直流汇流条供电。参见备用电源系统(AMM 第I部分24-34)。 电瓶 每个电瓶是一个48 安培小时,正常24伏的直流电源。如果所有其他电源不工作,主电瓶给APU起动供电并作为备用电源。辅助电瓶只作为主电瓶备用电源。 控制和保护 备用电源控制组件(SPCU)、电瓶电门,以及备用电源电门给直流系统提供主控制。 电瓶电门和备用电源电门对某些直流汇流条的电源进行人工控制。 SPCU 自动控制并保护直流汇流条。使用驾驶舱和系统监控的输入控制
49、直流电源和分配。 电源分配 直流电源分配系统在配电板(PDP )和SPCU 上。 直流电系统-主电瓶充电器和辅助电瓶充电器 目的 主电瓶充电器有下列两个功能: -保持主电瓶在最大充电量 -给电瓶汇流条提供直流电源 辅助电瓶充电器保持辅助电瓶在最大充电量。 概况介绍 两个电瓶充电器有相同的部件号。每个电瓶充电器有下列两种基本使用模式: -电瓶充电模式(恒定电流) -变压整流器模式(恒定电压) 在电瓶充电模式中,每个电瓶充电器提供恒定电流,可变电压电源。电瓶充电器给电瓶完全充电。电瓶充电器逻辑计算超充量,总的充电时间少于75 分钟。 在变
50、压整流(TR)模式下,主电瓶充电器给热电瓶汇流条和转换热电瓶汇流条提供恒压的直流电源。主电瓶也接受一些充电以保持主电瓶在最大充电量。在哪种模式下,辅助电瓶充电器也不能给直流汇流条供电。但是,当辅助电瓶充电器在 TR模式下时,辅助电瓶接受较小的充电。 每个电瓶充电器的前面板上有两个绿色状态灯(LED),一个是电瓶充电器的,另一个是电瓶的。当电瓶和电瓶充电器在工作时,这些灯亮。 位置 主电瓶充电器在E2架上,辅助电瓶充电器在E3架上。 功能介绍 每个电瓶充电器将三相、115 伏交流电源变成直流电源。通常,每个电瓶充电器在变压整流模式,此时,电瓶充电器提供恒定电压输出。这种