1、USER MANUALNl PXImc DevicesNl PXIe-8830mc PXImc Processor ModuleThis document provides reference information fbr PXI Express and the Nl PXIe-8830mc PXImc processor module.ContentsElectromagnetic Compatibility Guidelines.1Related Documentation.2PXI Express Features.2Benefits of PXI Express.2Nl PXIe-8
2、830mc Overview.3Functional Overview.3Functional Description.4National Instruments Software.5Configuration.7System CMOS.7Upgrading System Memory.8Specifications.9Physical.10Power Requirements.11Environment.11Cleaning.12Safety.12Appendix A:Front Panel Connector Pinouts.13Ethernet.13Universal Serial Bu
3、s.15Worldwide Support and Services.16Electromagnetic CompatibiHty GuidelinesThis product was tested and complies with the regulatory requirements and limits fbr electromagnetic compatibility(EMC)stated in the product specifications.These requirements and limits provide reasonable protection against
4、harmful interference when the product is operated in the intended operational electromagnetic environment.This product is intended fbr use in industrial locations.However,harmful interference may occur in some installations,when the product is connected to a peripheral device or test object,or if th
5、e product is used in residential or commercial areas.To minimize interference with4rNATI0NALINSTRUMENTSradio and television reception and prevent unacceptable performance degradation,install and use this product in strict accordance with the instructions in the product documentation.Furthermore,any
6、modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules./X Caution To ensure the specified EMC performance,operate this product only with/shielded cables and accessories.Caution To ensure the specified EMC
7、performance,USB cables must be no longer/than 30 m(100 ft).Ethernet cable can be longer than 30 m(100 ft).Related DocumentationThe following documents contain information that you might find helpful as you read this manual:Your chassis documentation Nl-PXImc Help file included with Nl-PXImc driver P
8、XI Express Hardware Specification.Revision 2.0 PXI-6 PXI Express Software Specification PIC MG CompactPCI Express EXP.0 R1.0 Specification PCI Express Base Specification,Revision 2.1,PCI Special Interest Group PXI MultiComputing Hardware Specification,Revision 1.0 PXI Multi Computing Software Specif
9、ication.Revision 1.0PXI Express FeaturesBenefits of PXI ExpressThe PXI(PCI extensions fbr Instrumentation)industry standard,an open specification governed by the PXI Systems Alliance(PXISA),has quickly gained adoption and grown in prevalence in test,measurement,and control systems since its release
10、in 1998.One of the key elements driving the rapid adoption of PXI is its use of PCI in the communication backplane.As the commercial PC industry has improved the available bus bandwidth by evolving PCI to PCI Express,PXI is now able to meet even more application needs by integrating PCI Express into
11、 the PXI standard.By taking advantage of PCI Express technology in the backplane,PXI Express increases the available PXI bandwidth from up to 132 MB/s to up to 8 GB/s for a more than 60 x improvement in bandwidth.PXI Express maximizes both hardware and software compatibility with PXI modules.PXI Exp
12、ress hybrid slots deliver both PCI and PCI Express signaling to accept devices that use PXI communication and triggering or the newer PXI Express standard.Software compatibility is maintained because PCI Express uses the same OS and driver model as PCI,resulting in complete software compatibility am
13、ong PCI-based systems,fbr example PXI,and PCI Express-based systems such as PXI Express.2|Nl PXImc Devices User ManualPXI Express,like PXI,leverages from the CompactPCI specification to define a rugged,modular form factor that offers superior mechanical integrity and easy installation and removal of
14、 hardware components.PXI Express products offer higher and more carefully defined levels of environmental performance required by the shock,vibration,temperature,and humidity extremes of industrial environments.Mandatory environmental testing and active cooling is added to the CompactPCI mechanical
15、specification to ease system integration and ensure multivendor interoperability.The demanding timing and synchronization requirements of instrumentation systems are met by the integrated features of PXI Express.Not only are the trigger bus,10 MHz system reference clock,and star trigger bus availabl
16、e in PXI retained by PXI Express,but new timing and synchronization features that include a 100 MHz differential system reference clock for the synchronization of multiple modules and three differential star trigger buses for the distribution of precise clock and trigger signals have been added.Diff
17、erential timing and synchronization signals provide PXI Express systems with increased noise immunity and the ability to transmit clock signals at higher frequencies.Nl PXIe-8830mc OverviewFunctional OverviewThe NI PXIe-8830mc is a PXImc device1 module that allows the attachment of subsystems such a
18、s standalone instruments,PCs,or other PXI Express systems to an existing PXI Express system via a high-bandwidth,low-latency PXI Express backplane Gen2 x8 link.The NI PXIe-8830mc contains a PXImc logic block that makes it possible to join systems together nontransparently.1 Refer to the PXI-7 PXI Mu
19、lti Computing Hardware Specification Revision 1.0,available on the pxisa.org website,fbr relevant terminology and concepts used in this guide.The following figure illustrates where the PXImc logic block is applied to join the root complexes of two systems.NI PXImc Devices User Manual|National Instru
20、ments|3Figure2-PXImc System DiagramIn this example,the system on the right is designated as a PXImc device because it contains the PXImc logic block(that is,the NI PXIe-8830mc).The system on the left is designated the primary system host,which serves as the central connection hub for all other PXImc
21、 devices.Refer to the Nl-PXImc Help and readme.html files included with the Nl-PXImc driver for feature updates.Functional DescriptionThe NI PXIe-8830mc is a modular PC in a PXI Express 3U-size form factor.The following figure is a functional block diagram of the NI PXIe-8830mc.Following the diagram
22、 is a description of each logic block shown.4|NI PXImc Devices User ManualFigure 2.Nl PXIe-8830mc Block DiagramThe NI PXIe-8830mc consists of the following logic blocks on one circuit card assembly(CCA):The processor is an Intel Core i7 4700EQ processor(6 MB Cache,2.3 GHz).The processor connects to
23、the SO-DIMM block through the DDR3L interface supporting up to 1600 MHz SO-DIMMs,the PCH through a x4 DMI2(Direct Media Interface)interface supporting up to 5 GT/s per lane.The SO-DIMM block consists of one 64-bit DDR3L SDRAM socket that can hold up to 8 GB of memory.The Platform Controller Huh(PCH)
24、provides the USB,PCI Express xl,and LPCinterfaces that connect to the peripherals on the NI PXIe-8830mc.The USB block consists of two Hi-Speed USB 2.0 connectors.The Ethernet Port block consists of an Intel 1217-LM Gigabit Ethernet Connection.The Watchdog block consists of a watchdog timer that can
25、reset the processor module or generate triggers.The PXI Express Connectors connect the NI PXIe-8830mc to the PXI Express/CompactPCI Express backplane.National Instruments SoftwareNational Instruments has developed several software tools you can use with the NI PXIe-8830mc.National Instruments5 hardw
26、are and software work together to help you make the most of your PXI Express system.The Lab VIEW,Measurement Studio,and LabWindows/CVI NI PXImc Devices User Manual|National Instruments|5application development environments combine with leading hardware drivers such as NI-DAQmx to provide exceptional
27、 control of NI hardware.Instrument drivers are available at ni com/idnet to simplify communication with instruments over a variety of buses.LabVIEW is a powerful and easy-to-use graphical programming environment you can use to acquire data from thousands of different instruments including USB,IEEE 4
28、88.2,VXI,serial,PLCs,and plug-in boards.LabVIEW helps you convert acquired data into meaningful results using powerful data analysis routines.Add-on tools provide additional specialized functionality.For more information,visit and you prefer to use Microsoffs Visual Basic,Visual C+,and Visual Studio
29、.NET for the core of your application,Measurement Studio adds tools for measurement and automation to each language.For more information,visit is an interactive ANSI C programming environment designed for building virtual instrument applications.LabWindows/CVI delivers a drag-and-drop editor for bui
30、lding user interfaces,a complete ANSI C environment for building your test program logic,and a collection of automated code generation tools,as well as utilities for building automated test systems,monitoring applications,or laboratory experiments.For more information,visit ni com/lwcvi.NI-DAQmx pro
31、vides an extensive library of functions you can call from your application development environment or interactive environment such as NI Signal Express.These functions provide an intuitive API for National Instruments multifunction DAQ products.Features available include analog input(A/D conversion)
32、,buffered data acquisition(highspeed A/D conversion),analog output(D/A conversion),waveform generation,digital I/O,counter/timer operations,SCXI signal conditioning,RTSI or PXI Express synchronization,self-calibration,messaging,and acquiring data to extended memory.For more information,visit Instrum
33、ents modular instruments use specialized drivers suited to each produefs specialization.Express Vis provide customized,interactive programming of instruments in a single interface and soft front panels provide an interface for testing the functionality of each instrument with no programming required
34、.NI Switches,DMMs,High-Speed DIO,High-Speed Digitizers,and Sources each have customized drivers for high-end modular instrumentation systems.RF applications leverage two drivers,NI-RFSG and NI-RFSA and Dynamic Signal Acquisition is available through NI-DAQmx.For more information,visit ni com/modular
35、instruments.You can expand the timing and triggering functionality of your PXI Express system with PXI Express Timing and Synchronization products.These products provide precision clock sources,custom routing of triggers for multichassis synchronization,clock sharing,and more and are programmed with
36、 Nl-Sync.For more information,visit is the National Instruments implementation of the VISA specification.VISA is a uniform API for communicating and controlling USB,Serial,GPIB,PXI,PXI Express,VXI,6|NI PXImc Devices User Manualand various other types of instruments.This API aids in the creation of p
37、ortable applications and instrument drivers.For information about writing your own PXI Express instrument driver with NI-VISA,refer to the NI-VISA Getting Started Manual and the readme.txt file in the NI-VISA directory.For more information,visit LabVIEW for Linux and support for more than two hundre
38、d devices on Linux with the NI-DAQmx driver,you now can create Virtual Instruments based on the Linux OS.The NI-VISA driver for Linux has improved instrument control in Linux,and NI Modular Instruments are partially supported.For more information,visit CMOSThe NI PXIe-8830mc contains memory backed u
39、p by a battery to store BIOS configuration information.Complete the following steps to clear the CMOS contents:1.Power off the chassis.2.Remove the processor module from the chassis.3.Press the push-button switch,as shown in the following figure.4.Wait 10 seconds.5.Reinstall the processor module in
40、the chassis.NI PXImc Devices User Manual|National Instruments|7Figure 3.Clearing the CMOS Contents1.Push-Button Switch SW1Upgrading System MemoryYou can change the amount of installed RAM on the NI PXIe-8830mc by upgrading theDDR3 SO-DIMMs.Complete the following steps to upgrade the RAM.1.Remove the
41、 NI PXIe-8830mc from the PXI Express chassis.2.Locate the DDR3 SO-DIMM module on the side of the processor module,as shown in the figure.3.Remove the installed DDR3 SO-DIMM module,if necessary.4.Install the new DDR3 SO-DIMM module into the slot.NI PXIe-8830mc System Memory InformationNational Instru
42、ments offers the following types of SO-DIMMs for use with theNI PXIe-8830mc processor module.Note National Instruments has tested and verified that the DDR3 SO-DIMMs we sell work with the NI PXIe-8830mc processor module.We recommend you purchase 8|NI PXImc Devices User Manualyour DDR3 SO-DIMM module
43、s from National Instruments.Other off-the-shelf DDR3 SO-DIMM modules are not guaranteed to work properly.PC3-12800(DDR3 1600)4 GB,256 MB x 64,CL 9,1.18 in.max(NI part number 782341-4096)PC3-12800(DDR3 1600)8 GB,512 MB x 64,CL 9,1.18 in.max(NI part number782341-8192)Figure 4.Installing a DDR3 SO-DIMM
44、 in an NI PXIe-8830mc Processor Module1.DDR3 SO-DIMM Module2.DDR3 SO-DIMM SocketSpecificationsThis section lists the system specifications for the following product only:NI PXIe-8830mc(156252x-011L)Note The NI assembly number in parentheses follows the model number.Ensure that the specifications of
45、interest match the NI assembly number on either the front or back side of the board.Note x denotes all assembly letter revisions.Note These specifications are typical at 25,unless otherwise stated,and are subject to change without notice.NI PXImc Devices User Manual|National Instruments|9PhysicalBoa
46、rd dimensions.2-Slot 3U PXI ExpressSlot requirements.Two peripheral slot(PXI Express)Weight.0.82 kg(1.80 lb)typicalFigure 5.Nl PXIe-8830mc Front Panel Dimensions5.067 in,128.70 mm3.750 in.95.24 mmEE 寸 8.0 寸一c一 8 8 9 L Elu 96NIJ.u一 z o z oEE 导6】.u-z z e o1.572 in.39.93 mm1.064 in.27.02 mm0.000 in.0.0
47、0 mm【EE 629二 Hsgo【EE 98.寸二.u一 989.0 EE ooo.u 一 000.010|Nl PXImc Devices User ManualPower RequirementsPower RailTypical CurrentMaximum Current+3.3 V1450 mA2180 mA+12 V3750 mA3940 mA+5 Vaux70 mA110 mANote:Does not include any attached USB devices.EnvironmentMaximum altitude.Pollution Degree.Indoor use
48、 only.Operating EnvironmentAmbient temperature range.(maximum performance)Ambient temperature range.Relative humidity range.Storage EnvironmentAmbient temperature range.Relative humidity range.Shock and VibrationOperational shock.2,000 m(800 mbar).2.0 to 40.0 to 55 (Tested in accordance with IEC-600
49、68-2-1 and IEC-60068-2-2.Meets MIL-PRF-28800F Class 3 low temperature limit and MIL-PRF-28800F Class 2 high temperature limit.).10 to 90%,noncondensing(Tested in accordance with IEC-60068-2-56.).-40 to 71 (Tested in accordance with IEC-60068-2-1 and IEC-60068-2-2.Meets MIL-PRF-28800F Class 3 limits.).5 to 95%,noncondensing(Tested in accordance with IEC-60068-2-56.).30 g peak,half-sine,11 ms pulse(Tested in accordance with IEC-60068-2-27.Meets MIL-PRF-28800F Class 2 limits.)Nl PXImc Devices User Manual|National Instruments|11Random VibrationOperating.5 to 500 Hz,0.3Nonoperating.5 to 500 Hz