1、Training TASC Driving Control Products,Driving the world,TASC/,George JIN,/,May 8,2003,*,DEVICENET,参数通道说明,以上说明仅供参考,详细内容请参看,SEW,样本,Fieldbus,Unit Profile with Parameter List,1,参数通道说明,The M-files are divided into a request file(M0-file)and a response file(M1-file).The data transmission is shown in fol
2、lowing Fig.,2,Request Telegram,:,3,4,Cmd,/status Code,:,5,Class,:,Register object class(class 7),The SEW parameter data channel can be addressed using the services,Get_Attribute_Single,and,Set_Attribute_Single,.The following possibilities for addressing the parameter data channel derive from the way
3、 the register object is specified by,DeviceNet,so INPUT objects can only be read and OUTPUT objects can be read and written.,Parameter object class(class 15),The,fieldbus,parameters of the SEW inverter can be addressed directly via the instance with the parameter object.In order to comply with the,D
4、eviceNet,specification,the data format for these instances deviates from the SEW,fieldbus,profile.However,it is also possible to address all parameters of the inverter via the parameter object.Instances 1 to 8 are reserved for this.,6,Instance,:,7,Response Telegram,:,The return codes are sent back i
5、n a different format in conjunction with,DeviceNet,.,The service code of an error message is always 94h(hex).,The general error code of an inverter-specific return code is always 1Fh=proprietary error.,The additional code is identical to the additional code low described in the manual for the,fieldb
6、us,device profile.,The example shows the proprietary error 10h=Impermissible parameter index.,8,TXID,要自己定义;,CMD,:,1,为执行,,4,为删除;,Connection,固定为,0,;,SIZE,为报体的长度,单位是,byte,;,Service:E,h,为读,,10,h,为写;,MAC_ID,:,DFD11B,的拨码地址;,读或写,Parameter,,,Class,需设为,7,;,Instance,:,1,为读,,2,为写,/,读;,对应,DeviceNet,Attribute,固定为,4,;,Data1,为要读取的,Parameter,的,Index,值,.,报头,报体,N7,:,0,到,N7,:,8,存放发送的报文;,N7:0,N7:1,N7:2,N7:3,N7:4,N7:5,N7:6,Example,:,读参数,INDEX,为,8304(2070,hex,),的值,9,报头,报体,N7,:,10,到,N7,:,15,存放收到的报文;,N7:15,N7:10,N7:11,N7:12,N7:13,N7:14,10,读参数,:,11,