1、書式設定,書式設定,第,2,第,3,第,4,第,5,#,FOR USER OF ELECTROSTATIC,HALF DEVAYED METER,MODEL,H-0110-S4,&,ANALYZING SYSTEM V2-S01,For many,Purpose,!,Electronics,Plastics,Film or Paper,Medical,(packaging),Chemical,Painting,ISO,STANDARD ISO/WD,18080-1,J,APAN,I,NDUSTRIAL,S,TANDARD JIS-L 1064,Static Decay Meter Hones
2、tmeter Model H-0110,1:Probe 2:Receiver Arm 3:High Voltage Meter 4:Mode Select switch 5:Current Meter,6:Connector for Analyzing System 7:Scale 8:Driver Arm 9:CAL Lamp,10:H.V,Adjust 11:MAIN Power lamp 12:Motor Lamp 13:High Voltage charging Lamp,14:Main Power Switch 15:Motor Switch 16:High Voltage Swit
3、ch,Receiver,DC Charger,Turning Table,Specimen,RECEIVER,DRIVER,AMPLIFIER,MOTOR,TURINIG TABLE,SPECIMEN,OPERATION,SYSTEM,High Voltage DC Power Supply,CONTROLER,(CPU),ANALOG/DIGITAL CONVERTING,RECORD EQUIPEMENT,CALIBRATED DATA,(FLASH MEMORY),COMMUNICATION SYSTEM,USB COMUNICATION,COMPUTOR,ANALYZING SYSTE
4、M V-2,STATIC HONESTMETER MODEL H-0110,Federal TEST METHOD STANDARD 101C-4046,For fast decay or low resistivity(under,10E6,)specimen,Manufacture:ets(U.S.A.),Suitable for the material resistivity,1x10E6 *1x10E13,Whole System,*PC and Printer must be prepared by customer,Temperature sensor cable,Groundi
5、ng cable,Power cable,USB cable,Signal cable,Grounding cable,Power cable,1:Power LED(green)2:Power Switch 3:AC Inlet 4:Fuse box 5:Grounding Terminal,6:Signal connector to H-0110 7:USB connector 8:Connector for temperature and humidity sensor,HONEST DATA ANALYZING SYSTEM-V2,Available PC,DOS/V model wi
6、th USB interface,Over Intel Pentium 500MHz,Memory:over 128MB,HDD Drive:over 2GB space,LCD monitor:we recommend over 1024768,Operation System,Windows 8(64bit),Windows 7(32bit),Windows Vista(32bit),、,XP(SP2,32bit),Windows XP Professional Edition,Windows XP Home Edition,Charging up,After Charged as Sat
7、urated Voltage,it start to decay.,This is the point of Half Decayed time.,Decayed its charged voltage,Check the really character of ESD!,Resistivity,Check is,not real ESD phenomena.,Charge up without any physical friction.,Every material can be measured.,Every material have,each potential characteri
8、stic,charged.,Saturated voltage(SAT),Slope Angle of decay curve,Half(50%),decayed time,Remained voltage,Resistivity,Material of conductivity,Humidity,What is the factor of,Charge Decay?,Half Decay is one of analysis,Depends on material,Sometime decay caracteristic is not same!,Resistivity or Decay t
9、ime?,1.28,x,10E9 ohm!Same?!?,This two sample Resistivity is,Sample No_01 is low charged and fast decay,Sample No_16 is high charged and slow decay,Resitivity of these two Sample is,Decay time is quite different!,1.00 x10E11,ohm,1.87x10E11,ohm,1.23x10E11,ohm,2.88x10E11,ohm,1.88x10E11,ohm,Different De
10、cay characteristic,Resistivity,10E11 ohm level,1.69x10E12,ohm,4.17x10E12,ohm,1.22x10E12,ohm,5.12x10E12,ohm,Different Decay characteristic,Resistivity,10E11 ohm level,Over,1x10E13,ohm,Cant be classified by Saturated voltage.,Safety Protection cover,While the operation door open,interlock magnet switch control the High voltage output and Motor.,After January 2012,for overseas model is modified as protection cover use.,