1、单击此处编辑母版标题样式,单击此处编辑母版文本样式,第二级,第三级,第四级,第五级,#,受压构件分为:轴心受压构件、偏心受压构件。,偏压构件分为:单向偏压构件、双向偏压构件,New Antioch Bridge.This high-level bridge completed in 1979 replaced an older truss-type lift bridge crossing the main shipping channel.The bridge consists of continuous spans of variable depth in Cor-Ten steel.M
2、aximum span is 460 ft,and maximum height of roadway above water level is 135 ft.(California),Elevated highway.Taken during construction.Designed as concrete box girders,these bridges were cast in place and post-tensioned.(Vienna,Austria),Highway interchange structure.Spans are all multi-cell reinfor
3、ced concrete box girders.Being stiff in torsion,these sections can be supported on a single line of columns,as well as on double columns or bents.(Oakland,California),Elevated highway,San Pablo Bay,California.The 2-story concrete frames supporting the roadway are loaded on the top beam by highway lo
4、ading,and transversely by inertia forces due to earthquake.(San Francisco Bay Area),工业和民用建筑中的单层厂房和多层框架柱,偏心受压构件,偏心受压构件拱和屋架上弦杆,以及水塔、烟囱的筒壁等属于偏心受压构件,偏心受压构件,7.1.1,材料的强度等级,7.1,受压构件的一般构造,*,混凝土常用,C25C40,或更高,*,钢筋常用,HRB335,,,HRB400,,不采用预应力钢筋,钢丝,钢绞线,减小构件截面尺寸,节省钢材,与混凝土共同受压时,不能充分发挥其高强作用,轴压构件:方形、圆形截面;,偏压构件:矩形、工形截
5、面。,(偏心力应沿长边布置),7.1.2,截面形式与尺寸,受压构件截面尺寸与长度一般控制,l,0,/,b,30,、,l,0,/,h,25,、,l,0,/,d,25,。并满足最小尺寸的要求;截面尺寸应符合模数要求。,7.1,受压构件的一般构造,内折角不应采用,内折角不应采用,复杂截面的箍筋形式,受压构件的配筋构造要求,箍筋,复合箍筋,复合箍筋,拉筋,在实际结构中,理想的轴心受压构件几乎是不存在的。,通常由于施工制造的误差、荷载作用位置的偏差、混凝土的不均匀性等原因,往往存在一定的初始偏心距。,但有些构件,如以恒载为主的等跨多层房屋的内柱、桁架中的受压腹杆等,主要承受轴向压力,可近似按轴心受压构件
6、计算。,1.,轴心受压柱内,纵筋,的作用:,提高正截面受压承载力;,改善破坏时的脆性,即提高变形能力;,防止因偶然偏心而突然破坏;,减小混凝土的徐变变形。,2.,箍筋,的作用:防止纵筋的压曲,并与纵筋组成能站立的钢筋骨架。,协助混凝土受压,受压钢筋最小配筋率:,0.4%,(,单侧,0.2%),承担弯矩作用,减小持续压应力下混凝土收缩和徐变的影响。,7.2,轴心受压构件的承载力计算,3.,轴心受压柱的分类:根据,长细比,分为,长柱和短柱,。,(,短柱,:矩形截面柱,l,0,/b,8,圆形截面柱,l,0,/d,7,,任意截面柱,l,0,/i28,),7.2,轴心受压构件的承载力计算,1.,轴心受压
7、短柱的破坏形态及应力重分布,在轴心荷载作用下整个截面的应变基本上是均匀分布的。,当外力较小时压缩变形的增加与外力的增长成正比,但外力稍大后,变形增加的速度快于外力增长的速度,配置纵筋数量越少,这个现象越为明显,。,随着外力的继续增加,柱中开始出现微细裂缝,在临近破坏荷载时,柱四周出现明显的纵向裂缝,箍筋间的纵筋发生压屈,向外凸出,混凝土被压碎而整个柱破坏,7.2,轴心受压构件的承载力计算,N,初始受力,试验表明,在整个加载过程中,由于钢筋和混凝土之间存在着粘结力,两者压应变基本一致,钢筋与混凝土的应力,变形条件:,物理关系:,平衡条件:,1,E,s,钢筋:,混凝土:,混凝土徐变对轴心受压构件的
8、影响,由于混凝土在长期荷载作用下具有徐变性质,而钢筋在常温情况下没有徐变。因此,当轴心受压构件在恒定荷载的长期作用下,混凝土徐变将使构件中钢筋和混凝土的应力发生变化。,徐变引起的应力重分布,徐变系数随时间的增长而增大,钢筋的压应力不断增大,混凝土中的压应力则不断减小。这种应力的变化是在外荷载没有变化的情况下产生的,称为徐变引起的应力重分布。,因此,徐变产生的应力重分布,对混凝土的压应力起着卸荷作用,配筋率,r,越大,钢筋的压应力的增长越少,混凝土中的压应力的卸载越多。,矩形截面轴心受压,长柱,前述是短柱的受力分析和破坏特征。对于长细比较大的长柱,试验表明,,由于各种偶然因素造成的初始偏心距的影
9、响是不可忽略的,。加载后由于有,初始偏心距,将产生,附加弯距,,这样相互影响的结果使长柱最终在,弯矩及轴力共同作用下发生破坏,。对于长细比很大的长柱,还有可能发生,“失稳破坏,”的现象,长柱的破坏荷载低于其他条件相同的短柱破坏荷载。,稳定系数,试验表明,长柱的破坏荷载低于其他条件相同的短柱破坏荷载。,规范,中,采用稳定系数,表示承载能力的降低程度,即,轴心受压,短,柱,轴心受压,长,柱,稳定系数,稳定系数,j,主要与柱的长细比,l,0,/,b,有关,可靠度调整系数,0.9,是考虑初始偏心的影响,以及主要承受恒载作用的轴心受压柱的可靠性。,3.,承载力计算公式,-,普通钢箍柱,7.2.2,轴心受
10、压螺旋箍筋柱的正截面承载力计算,柱承受很大轴心受压荷载,并且柱截面尺寸由于建筑上及使用上的要求受到限制,若按配有纵筋和箍筋的柱来计算,即使提高了混凝土强度等级和增加了纵筋配筋量也不足以承受该荷载时,可考虑采用螺旋筋柱或焊接环筋柱以提高构件的承载能力。,但这种柱因施 工复杂,用钢量较多,造价较高,一般很少采用。,柱的截面形状一般为圆形或多边形。,试验表明,柱受压后产生横向变形,横向变形受到螺旋筋的约束作用,提高了混凝土的强度和变形能力,构件的承载力也就提高,同时在螺旋筋中产生了拉应力。当外力逐渐加大,它的应力达到抗拉屈服强度时,就不再能有效地约束混凝土的横向变形,混凝土的抗压强度就不能再提高,这
11、时构件达到破坏,。,螺旋筋外的混凝土保护层在螺旋筋受到较大拉应力时 就开裂,甚至脱落,故在计算时不考虑此部分混凝土。,螺旋筋和焊接环筋的作用:,可以使核心混凝土处于三向受压状态,提高了混凝土的抗压强度和变形能力,从而间接提高了轴心受压柱的受压承载力和变形能力,螺旋筋和焊接环筋也可称为“间接纵向钢筋”或“间接钢筋”。,被约束后的混凝土轴心抗压强度可用下式计算,f*,-,有侧向压力约束的混凝土轴心抗压强度。,r,当,螺旋筋,的应力达到屈服强度时,柱的核心混凝土受到的径向压应力值。,A,ss1,单根间接钢筋的截面面积;,f,y,间接钢筋的抗拉强度设计值;,s,沿构件轴线方向间接钢筋的间距;,d,co
12、r,构件的核心直径;,A,sso,间接钢筋的换算截面面,由平衡条件得:,A,sso,间接钢筋的换算截面面,核心混凝土面积,据纵向内外力的平衡,得到螺旋式或焊接环式间接钢筋柱的承载力计算公式如下:,承载力计算公式,注:,1.,为使间接钢筋外面的混凝土保护层对抵抗脱落有足够的安全,,规范,规定螺旋式箍筋柱的承载力不应比普通箍筋柱的承载力大,50,。,2.,凡属下列情况之一者,不考虑间接钢筋的影响而按普通箍筋柱计算承载力:,(1),当,l,0,/d,12,时,因长细比较大,因纵向弯曲引起螺旋筋不起作用;,(2),当算得受压承载力小于按普通箍筋柱算得的受压承载力;,(3),当间接钢筋换算截面面积小于纵
13、筋全部截面面积的,25,时,可以认为间接钢筋配置得太少,套箍作用的效果不明显。,。,7.3,偏心受压构件正截面的破坏形态,压弯构件 偏心受压构件,偏心距,e,0,=0,时,轴心受压构件,当,e,0,时,即,N,=0,时,受弯构件,偏心受压构件的受力性能和破坏形态界于,轴心受压,构件和,受弯构件,。,一、破坏特征,偏心受压构件的破坏形态与,偏心距,e,0,和,纵向钢筋配筋率,有关,1、受拉破坏,tensile failure,M,较大,,N,较小,偏心距,e,0,较大,A,s,配筋合适,一、破坏特征,偏心受压构件的破坏形态与,偏心距,e,0,和,纵向钢筋配筋率,有关,1、受拉破坏,tensile
14、 failure,截面受拉侧混凝土较早出现裂缝,,A,s,的应力随荷载增加发展较快,,首先达到屈服,。,此后,裂缝迅速开展,受压区高度减小,最后受压侧钢筋,A,s,受压屈服,压区混凝土压碎而达到破坏。,这种破坏具,有明显预兆(延性破坏),,变形能力较大,破坏特征与配有受压钢筋的适筋梁相似,,承载力主要取决于受拉侧钢筋,。,形成这种破坏的条件是:,偏心距,e,0,较大,且受拉侧纵向钢筋配筋率合适,,通常称为,大偏心受压。,受拉破坏时的截面应力和受拉破坏形态,(,a,)截面应力 (,b,)受拉破坏形态,2、受压破坏,compressive failure,产生受压破坏的条件有两种情况:,当相对偏心
15、距,e,0,/,h,0,较小,或虽然相对偏心距,e,0,/,h,0,较大,但受拉侧纵向钢筋配置较多时,A,s,太多,截面受压侧混凝土和钢筋的受力较大,,而受拉侧钢筋应力较小,,当相对偏心距,e,0,/,h,0,很小时,受拉侧还可能出现受压情况。,截面最后是由于受压区混凝土首先压碎而达到破坏,,承载力主要取决于压区混凝土和受压侧钢筋,破坏时受压区高度较大,受拉侧钢筋,未达到,受拉屈服,,破坏具有脆性性质。,第二种情况在设计应予避免,,因此受压破坏一般为偏心距较小的情况,故常称为,小偏心受压,。,2、受压破坏,compressive failure,产生受压破坏的条件有两种情况:,当相对偏心距,e
16、0,/,h,0,较小,或虽然相对偏心距,e,0,/,h,0,较大,但受拉侧纵向钢筋配置较多时,受压破坏时的截面应力和受压破坏形态,(,a,)、(,b,)截面应力(,c,)受压破坏形态,7.4,矩形截面偏心受压构件正截面受压承载力的计算公式,7.4.1,两种破坏形态的界限及其截面应力计算图形,偏心受压正截面受力分析方法与受弯情况是相同的,即仍采用以,平截面假定,为基础的计算理论。,根据混凝土和钢筋的应力,-,应变关系,即可分析截面在压力和弯矩共同作用下受力全过程。,对于正截面承载力的计算,同样可按受弯情况,对受压区混凝土采用等效矩形应力图。,等效矩形应力图,的强度为,a f,c,,等效矩形应力
17、图的高度与中和轴高度的比值为,b,。,受拉破坏和受压破坏的界限,即,受拉钢筋屈服,与,受压区混凝土边缘极限压应变,e,cu,同时达到,与适筋梁和超筋梁的界限情况类似。,因此,,相对界限受压区高度,仍为,,当,x,x,b,时,当,x,x,b,时,受,拉,破坏(大偏心受压),受,压,破坏(小偏心受压),7.4.2,附加偏心距、初始偏心距、偏心距增大系数,由于施工误差、荷载作用位置的不确定性及材料的不均匀等原因,实际工程中不存在理想的轴心受压构件。为考虑这些因素的不利影响,引入,附加偏心距,e,a,,,即在正截面受压承载力计算中,偏心距取计算偏心距,e,0,=,M,/,N,与附加偏心距,e,a,之和
18、称为,初始偏心距,e,i,参考以往工程经验和国外规范,附加偏心距,e,a,取,20mm,与,h,/30,两者中的较大值,此处,h,是指偏心方向的截面尺寸。,一、附加偏心距,二、偏心距增大系数,由于侧向挠曲变形,轴向力将产生,二阶效应,,引起附加弯矩,对于长细比较大的构件,二阶效应引起附加弯矩不能忽略。,图示典型偏心受压柱,跨中侧向挠度为,f,。,对跨中截面,轴力,N,的,偏心距为,e,i,+,f,,,即跨中截面的弯矩为,M,=,N,(,e,i,+,f,)。,在截面和初始偏心距相同的情况下,柱的,长细比,l,0,/,h,不同,侧向挠度,f,的大小不同,影响程度会有很大差别,将产生不同的破坏类型
19、对于,长细比,l,0,/,h,8,的,短柱,,侧向挠度,f,与初始偏心距,e,i,相比很小,可忽略挠度,f,影响。,因此,对于中长柱,在设计中应考虑附加挠度,f,对弯矩增大的影响。,二、偏心距增大系数,偏心距增大系数,1,:,偏心受压构件截面曲率修正系数 ,当 取,2,:,构件长细比对截面曲率的影响系数 当 取,根据试验和理论分析,,混凝土结构设计规范,规定:,7.4.3,矩形截面偏心受压构件在正截面承载力的计算公式及适用条件,一、大、小偏心受压破坏的初步判定,可先按照大偏心受压破坏进行计算,求出,x,后,如果 ,则按照小偏心受压破坏重新计算。,可按照小偏心受压破坏进行计算,二、大偏心受压
20、受拉破坏),7.4.3,矩形截面偏心受压构件在正截面承载力的计算公式及适用条件,适用条件:,如果:可取 。,7.4.3,矩形截面偏心受压构件在正截面承载力的计算公式及适用条件,适用条件:,三、小偏心受压(受压破坏),7.5,对称配筋矩形截面偏心受压构件正截面承载力计算,宜采用对称配筋的情况:,1,、偏心受压柱在不同荷载作用下,可能发生反向的弯矩,且两者差值不大;,2,、即使两者差距很大,但按照对称配筋所得的钢筋的总量比非对称配筋设计所得纵筋总量增加不多时;,3,、装配式柱。,7.5,对称配筋矩形截面偏心受压构件正截面承载力计算,大小偏心受压破坏的判别条件:,小偏心受压,大偏心受压,7.5,对
21、称配筋矩形截面偏心受压构件正截面承载力计算,截面设计:,大偏心,受压破坏的截面设计基本公式及使用条件,适用条件:,7.5,对称配筋矩形截面偏心受压构件正截面承载力计算,截面设计:,小偏心,受压破坏的截面设计基本公式及使用条件,适用条件:,7.5,对称配筋矩形截面偏心受压构件正截面承载力计算,截面复核:,已知轴向压力值,N,及偏心距,截面尺寸,混凝土强度等级,钢筋级别及截面面积,要求计算截面所能抵抗的轴力。,当,N,未知,只已知偏心距,可先假设截面曲率修正系数,初步求出,Nu,之后,再令,N=Nu,,算出 ,然后再求,Nu,。,7.5,对称配筋矩形截面偏心受压构件正截面承载力计算,截面复核:,大偏心受压破坏的截面复核,1,、当,h,e,i,e,ib.min,=0.3,h,0,,为大偏心受压,根据上式计算出,x,。,7.5,对称配筋矩形截面偏心受压构件正截面承载力计算,截面复核:,小偏心受压破坏的截面复核,1,、当,h,e,i,N,b,)为受压破坏。,如截面尺寸和材料强度保持不变,,N,u,-,M,u,相关曲线随配筋率的增加而向外侧增大。,