收藏 分销(赏)

英文版臭氧发生器说明书.doc

上传人:pc****0 文档编号:8988358 上传时间:2025-03-10 格式:DOC 页数:8 大小:1.97MB
下载 相关 举报
英文版臭氧发生器说明书.doc_第1页
第1页 / 共8页
英文版臭氧发生器说明书.doc_第2页
第2页 / 共8页
点击查看更多>>
资源描述
CAUTION: READ INSTRUCTIONS THOROUGHLY BEFORE OPERATION OF UNIT Ozone Generator Manual 1.0 Introduction NOTE: All specifications stated in this manual may change without notice. 1.1 What is ozone? Ozone series is to clean the air or water in the same way nature uses lightning to create ozone to clean the air naturally. Ozone is very unstable and attaches to contaminants, mold, odors, etc. This reaction results in previously contaminated areas smelling fresh and clean. 1.2 Placement and Setting of Machine 1.2.1. Do not use this product near high-precision electronic equipment, radio interference may be caused by the misuse of high-precision electronic equipment and other problems. Especially need to pay special attention to the vicinity of the following equipment: hearing aids, pacemakers and other medical electronic equipment, fire detectors, and other precision automatic control device. 1.2.2. Do not disassemble or modify the product, otherwise it may cause the damage, leakage and circuit failure. 1.2.3. Avoid excessive moisture, water or other liquids enter the product otherwise leakage and failure of the product may cause. 1.2.4. Avoid volatile solution or organic solvents to wipe the device, as it may damage the surface of the device. 1.2.5. Qualified dedicated grounding wire, secure and reliable grounding line capacity is required to ensure the elimination of fire hazards. Equipment installation personnel must be trained in order to boot repair. 1.2.6. Use ozone generator in unoccupied room only. The staff should have Protective measures when ozone concentrations exceed the relevant standards in the space environment. 1.2.7. Equipment maintenance or repair must be power off and drain the air pressure to ensure the safety of personnel maintenance. 1.3. Environmental Conditions of Machine 1.3.1 Indoor Installment should be non-flammable or explosive gases and conductive dust. Prohibiting the installation to where ammonia is easy to leak or explosion hazard danger zone 1.3.2 220V/50HZ AC power supply, 110V/50Hz (optional, must specify when ordering) 1.3.3 Environmental Temperature Requirements: -10 ℃ -33 ℃ 1.3.4 Environment humidity requirements: ≤ 55%. 1.3.5 Keep the equipment working environment ventilation when install this equipment, the space required to install exhaust fans or air conditioning. 2. Technical Specification Model Ozone Output (g/h) Power (W) Dimension(mm) Cooling Type Air source HY-005-10A 10 180 32*26*58 Air-cooling air feeding 3. Parts Include: Ozone generator (1) Air stone (1) 3 meters of silicone tube (1) Operation manual (1) Warranty card (optional) 4. Applications 4.1 Air purify: Food processing plant, cosmetic plant, refrigerator, file room, Cafeteria, pharmaceutical factory, schools, hotel, hospitals, restaurants etc 4.2 Water treatment: Mineral water, bottled water, pure water, swimming pool, aquaculture, farm feeding water, beverage plant, industrial wastewater, and cooling tower system, etc. 5. Operation Instructions 5.1 Placed the ozone generator to a smooth, airy location. 5.2 Connected cooling water (For water cooling type machine) 5.3 Plug in the 220VAVC power, turn on the pump switch first. 5.4 Extension of time to open the ozone switch (depend on air humidity, higher humidity, longer time, usually 1-30 seconds), ozone indicator light, the machine starts to work ozone output from outlet. 5.5 Adjust the ozone concentration by switch the concentration knob 5.6 Offer disinfection, manually shut down the machine (25g ozone generator don’t have a timer, additional configuration) unplug 5.7 Ozone in the air will automatically broken down into oxygen in 1-2 hours, people should come in the room for a long time when there is no strong odor of ozone 5.8 Take the machine to dry and airy location, in case of stagnant water cause by high temperature, high humidify environment in the machine Notes: Before turn on the power, this machine must be connected cooling water (For water-cooling type machine), prohibited from running without connected cooling water. 6. Warranty From the date of your purchase, free one-year warranty and lifetime maintenance. 7. Fault Inspection and Analysis 7.1 Fault Inspection List Equipment status Causes Solutions Remarks No power 1. Power plug loose 2. No 220V voltage Plug in 220V/60HZ power No gas output from outlet 1. Regular inspection to know whether the internal wiring joint is loose 2.Whether a block in the pipes 3. Whether air pump switch was turned on or not 1.Cut down the power,then opening the back cover to check the pipes or wirings 2.Turn on the air pump switch Be careful!Must cut down the power to open the back cover. Gas supply regular, no ozone output 1. Whether ozone switch is turned on or not 2.Concentration Adjustment is 0 levels. 3.Control panel is out of control 4.Electrical discharge is damaged 1.Turn on the ozone switch button 2. To adjust the concentration button 3. Check the electrocircuit. 4.To change the electrical discharge Case leakage 1.Ungrounded electrical application at your local 2.Humidity Power supply should be ungrounded electrical application 2.To install the ozone generator in dry place Operating machine’s fuse burn-out, or tripping 1. Short Circuit 2 Electrical discharge is damaged 1. Check the electrocircuit 2. To change the electrical discharge Water store inside the machine 1. A backflow of water from operating water treatment into the ozone generator tube 2.Humidity 3.Undisposed air source 1.To dry inner ozone generator tube 2. To dry the inner machine box 3.Drying process for air source In case of water into machine during the running, it is necessary to stop the machine Immediately to check and remove the faults If the problem unsolved after above checking, contact our sales or service stuffs directly. 7.2. Using Notes 7.2.1 Machinery and equipment must be placed in the oilless, clean dry air environment location to extend the lifespan of the machinery and equipment. 7.2.2 Handled gently when using, not abandonment. 7.2.3 Machinery and equipment used in water treatment, ozone output port must be connected to the check valve to prevent backwater into the machine, and damage to the machine. 7.2.4 Prohibition of placing the machine to disinfection area ,for safety , the device should have a separate working area, then use the silicone tube to deliver ozone to disinfection and chemical reaction zone. 7.2.5 Machinery and equipment must check every day before using; any abnormal should immediately shut down, and identify the reasons, solve the problem then use. 7.2.6 This machine must be well grounded to prevent lightning. Better to unplug the power when not working. 7.2.7 According to the working environment, using requirements choose the corrective ozone generator. 7.2.8 For a long time no use, the machine should be cleaned and place to a dry ventilated place to prevent damage from moisture. 7.2.9 In order to prevent the machine from moisture and better maintenance , open pump switch or gas control switch; switch off "Density Adjustment" or "ozone switch" to work more than three hours weekly to clean the inside of water vapor 8. Maintenances 8.1Keep the equipment in a dry ventilated place, dust network (cooling fan ) cleaned once a month 8.2 Non-professional electrician, do not open the box (with high pressure) ,+ 8.3 Silicone tube replaced every three months 8.4 Checking whether inside connector is loose or hose aging. If the connector is loose, tighten with a screwdriver, hose aging, timely replacement 8.5 Our customer can get accessories from us with a low cost (lower than the market price) 8.6 Power on, open air pump switch first, after 1-2 minutes open ozone switch, shut down, first turn off the ozone switch, after 1-2 minutes, turn off air pump switch. ANNEX 1 City Drinking Water Treatment ANNEX 2 Central Air-conditioning Ozone Generator Systems 8
展开阅读全文

开通  VIP会员、SVIP会员  优惠大
下载10份以上建议开通VIP会员
下载20份以上建议开通SVIP会员


开通VIP      成为共赢上传
相似文档                                   自信AI助手自信AI助手

当前位置:首页 > 包罗万象 > 大杂烩

移动网页_全站_页脚广告1

关于我们      便捷服务       自信AI       AI导航        抽奖活动

©2010-2025 宁波自信网络信息技术有限公司  版权所有

客服电话:4009-655-100  投诉/维权电话:18658249818

gongan.png浙公网安备33021202000488号   

icp.png浙ICP备2021020529号-1  |  浙B2-20240490  

关注我们 :微信公众号    抖音    微博    LOFTER 

客服