收藏 分销(赏)

ErP&New Energy Labelling for Air Conditioner 英文版.ppt

上传人:wei****ing 文档编号:8065277 上传时间:2025-02-02 格式:PPT 页数:27 大小:2.69MB 下载积分:5 金币
下载 相关 举报
ErP&New Energy Labelling for Air Conditioner 英文版.ppt_第1页
第1页 / 共27页
ErP&New Energy Labelling for Air Conditioner 英文版.ppt_第2页
第2页 / 共27页


点击查看更多>>
资源描述
,Click to edit Master title style,Click to edit Master text styles,Second level,Third level,Fourth level,Fifth level,*,Click to edit Master title style,Click to edit Master text styles,Second level,Third level,Fourth level,Fifth level,*,ErP,&New Energy Labelling for Air Conditioner,Prepared By:Jeff Zhang(,张辉,),Intertek Guangzhou,Contents,Development of standard EN 14825,ErP,implementing measures Introduction,New Energy Label Introduction,Introduction of Intertek GZ Energy Efficiency Team,Development of standard EN 14825,EN 14825“Air conditioners,liquid chilling packages and heat pumps,with electrically compressors,for space heating and cooling Testing and rating at part load conditions and calculation of seasonal performance“.Formal vote before end 2011.,Will be the harmonized standard for the European Directive,and energy,labelling,of air conditioners.,Developed using the data of a preliminary study of the European Commission,determining average climates in Europe+types of buildings and internal loads schedules.,Bin method(number of hours at a given outdoor temperature),Includes the electrical input when the unit is not cooling nor heating.,Development of standard EN 14825,thermostat off mode,mode corresponding to the hours with no cooling or heating load of the building,whereby the cooling or heating function of the unit is switched on,but is not operational,as there is no cooling or heating load.In most cases,the indoor fan is running,standby mode,the unit is switched off partially and can be reactivated by a control device or timer,crankcase heater mode,mode corresponding to the hours where a crankcase heater is activated,Development of standard EN 14825,Cooling mode,for Air-to-air units,:,Tj,=the bin temperature;,j=the bin number;,n=the amount of bins;,Pc(Tj,)=the cooling demand of the building for the corresponding temperature,Tj,;,hj,=the number of bin hours occurring at the corresponding temperature,Tj,;,EER(Tj,)=the EER values of the unit for the corresponding temperature,Tj,.,Development of standard EN 14825,Hours for each bin temperature,Reference SEER,HTO,HSB,HCK,HOFF=the number of hours the unit is considered to work in respectively thermostat off mode,standby mode,crankcase heater mode and off mode;,PTO,PSB,PCK,POFF=the electricity consumption during respectively thermostat off mode,standby mode,crankcase heater mode and off mode,expressed in kW.,With(,Hce,=350 hours),Development of standard EN 14825,Example for ESEER,Non ducted split high wall,Fixed capacity,CLASP,Cooling benchmarking study,June 2011,Development of standard EN 14825,Example for ESEER,Non ducted split high wall,Inverter,CLASP,Cooling benchmarking study,June 2011,Development of standard EN 14825,Heating mode:,TOL,Temperature,operation,limit,(,lower,temperature,),Tbivalent,Lower,temperature,the,heat,pump,can,satisfy,the,heating,load,Heating mode,T outdoor,T indoor,Development of standard EN 14825,Thermal,Building,heating,load,Heat pump capacity,Outdoor temp.,-15,Tol,-7,Tbiv,2 7 12 16,-10,T,design,P,design,Heating,needs covered by resistance electrical heater,COP=1,Heating,needs covered by the heat pump,EU MEPS,EcoLabel,Directive,Minimum requirements for the European Directive,EU MEPS,EcoLabel,Directive,Single duct&Double duct from 2013-1-1,Off mode,Power consumption of equipment in any off-mode,condition shall not exceed 1,00 W.,Standby mode,The power consumption of equipment in any condition providing only a reactivation function,or,providing only a reactivation function and a mere indication of enabled reactivation function,shall not,exceed 1,00 W,except for double and single duct air conditioners with inverters for which the standby,mode power consumption shall not exceed 8W.,The power consumption of equipment in any condition providing only information or status display,or,providing only a combination of reactivation function and information or status display,shall not,exceed 2,00 W,except for double and single duct air conditioners with inverters for which the standby,mode power consumption shall not exceed 8W.,Availability of,standby and/or,off mode,Equipment shall,except where this is inappropriate for the intended use,provide off mode and/or,standby mode,and/or another condition which does not exceed the applicable power consumption,requirements for off mode and/or standby mode when the equipment is connected to the mains power,source.,EU MEPS,EcoLabel,Directive,Single duct&Double duct from 201,4,-1-1,Off mode,Power consumption of equipment in any off-mode,condition shall not exceed,0,5,0 W.,Standby mode,The power consumption of equipment in any condition providing only a reactivation function,or,providing only a reactivation function and a mere indication of enabled reactivation function,shall not,exceed,0,5,0 W,except for double and single duct air conditioners with inverters for which the standby,mode power consumption shall not exceed 8W.,The power consumption of equipment in any condition providing only information or status display,or,providing only a combination of reactivation function and information or status display,shall not,exceed,1,00 W,except for double and single duct air conditioners with inverters for which the standby,mode power consumption shall not exceed 8W.,Availability of,standby and/or,off mode,Equipment shall,except where this is inappropriate for the intended use,provide off mode and/or,standby mode,and/or another condition which does not exceed the applicable power consumption,requirements for off mode and/or standby mode when the equipment is connected to the mains power,source.,EU MEPS,EcoLabel,Directive,Single duct&Double duct from 201,4,-1-1,Power,management,When equipment is not providing the main function,or when other energy-using,product(s,)are not dependent,on its functions,equipment shall,unless inappropriate for the intended use,offer a power management,function,or a similar function,that switches equipment after the shortest possible period of time appropriate,for the intended use of the equipment,automatically into:,standby mode,or,off mode,or,another condition which does not exceed the applicable power consumption requirements for off mode,and/or standby mode when the equipment is connected to the mains power source.The power management,function shall be activated before delivery.,EU MEPS,EcoLabel,Directive,Minimum requirements for the European Directive,Mandatory f,rom 2013-01-01,EU Energy Labelling,More Efficiency rating are allowed,New Evaluation Methods are introduced for Split&Window,air conditioner,SEER for cooling mode,SCOP for heating mode,Region Climate factors have been considered,More strict Surveillance tolerance,EU Energy Labelling,Energy efficiency classes for air conditioners,except double ducts,and single ducts,EU Energy Labelling,Energy efficiency classes for double ducts and single ducts,Energy,E,fficiency,Class,Double ducts,Single duct,EER,rated,COP,rated,EER,rated,COP,rated,A+,4.10,4.60,4.10,3.60,A+,3.60,4.10,3.60,3.10,A+,3.10,3.60,3.10,2.60,A,2.60,3.10,2.60,2.30,B,2.40,2.60,2.40,2.00,C,2.10,2.40,2.10,1.80,D,1.80,2.00,1.80,1.60,E,1.60,1.80,1.60,1.40,F,1.40,1.60,1.40,1.20,G,1.40,1.60,1.4,=92%of rating,EER or COP=90%of rating,Noise=92%of rating,EER or COP=90%of rating,Noise=Rating+2,dBa,Household Electrical Appliances,AC and Heat Pumps,Electrical Ovens,PTACs,Heat Pump Water Heaters,Spot Air conditioners,Clothes Dryers,Dehumidifiers,Refrigerator,Freezers,Water coolers,Microwave Ovens,Ceiling Fans,Standby/off mode for household electrical appliances,Information Equipment,Personal Computers,Laptops,Home electronics,Televisions,Audio equipments,Video Equipments,Set top boxes,Energy Efficiency Team,Others,Battery Charger Systems,External Power supplies,Power supply for computers,Other Refrigeration appliances,Commercial Refrigeration Products,Energy Efficiency Team,EuP,Directive Compliance,Energy Label Program for Europe,Eco Label Program for Europe,Energy Label Program for Australia,MEPS Program for Australia,Energy Guide Program for US and Canada,EEV program for Canada,Energy Star Program,CEC certification Program,Energy Label and MEPS Program for SASO,Energy Saving Code for Kuwait,China Energy Label Program,Hong Kong Energy Label Program,Energy Label Program for India,Energy Label Program for Singapore,Energy Label Program for China,More,Energy Efficiency Team,Qualification of Lab,CNAS accreditation lab,IAS accreditation lab,EPA recognized lab,CEC approved lab,Appliance:,AC&HP,Dehumidifier,Capacity:,5000 3600 Btu/h,Type:,Window type,Split type,Floor standing type,Portable type,Facility ETL Balanced Ambient Chamber,Appliance:,Refrigerator,Freezer,Water dispenser,Commercial refrigeration product,Facility Walk-in Chamber,Any Questions?,
展开阅读全文

开通  VIP会员、SVIP会员  优惠大
下载10份以上建议开通VIP会员
下载20份以上建议开通SVIP会员


开通VIP      成为共赢上传

当前位置:首页 > 教育专区 > 其他

移动网页_全站_页脚广告1

关于我们      便捷服务       自信AI       AI导航        抽奖活动

©2010-2026 宁波自信网络信息技术有限公司  版权所有

客服电话:0574-28810668  投诉电话:18658249818

gongan.png浙公网安备33021202000488号   

icp.png浙ICP备2021020529号-1  |  浙B2-20240490  

关注我们 :微信公众号    抖音    微博    LOFTER 

客服