1、玻璃绝缘子参数精品资料环球-光电公司玻璃绝缘子(交流)型号一览表 2010-7-23光电公司玻璃绝缘子(交流)型号一览表2008-6-21交流系统用盘形悬式绝缘子标准型绝缘子型号U70B/146U80B/146U100B/146U120B/146U160B/155U210B/170U240B/170U300B/195U420B/205U550B/240公称直径D(mm)255255255255280280280320360360结构高度H(mm)146146146146155170170195205240公称爬电距离L(mm)320320320320400400400485550620连接标记
2、(mm)16161616202024242832额定机械破坏负荷(kN)7080100120160210240300420550逐个拉伸负荷试验(kN)3540506080105120150210275工频干耐受电压(kV)70707070757575859095工频湿耐受电压(kV)40404040454545505555雷电冲击耐受电压(kV)100100100100110110110130140145冲击过电压击穿耐受电压(p.u.)2.82.82.82.82.82.82.82.82.82.8最小工频击穿耐受电压(kV)130130130130130130130130130130无线电干
3、扰10kV;1MHz(V)50505050505050505050可见电晕电压 脚/帽(kV)18/2218/2218/2218/2218/2218/2218/2218/2218/2218/22工频电弧试验0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA绝缘子单片重量(kg)3.63.64.04.06.57.27.510.614.619.1交流系统用盘形悬式绝缘子空气动力型绝缘子型号U70BP/146MU80BP/146MU100BP/146M
4、U120BP/146MU160BP/155MU210BP/170MU240BP/170M公称直径D(mm)380380380380420420420结构高度H(mm)146146146146155170170公称爬电距离L(mm)365365365365380380380连接标记(mm)16161616202024额定机械破坏负荷(kN)7080100120160210240逐个拉伸负荷试验(kN)3540506080105120工频干耐受电压(kV)55555555606060工频湿耐受电压(kV)45454545505050雷电冲击耐受电压(kV)90909090959595冲击过电压击穿
5、耐受电压(p.u.)2.82.82.82.82.82.82.8最小工频击穿耐受电压(kV)130130130130130130130无线电干扰10kV;1MHz(V)50505050505050可见电晕电压 脚/帽(kV)18/2218/2218/2218/2218/2218/2218/22工频电弧试验0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA绝缘子单片重量(kg)5.65.65.65.67.08.99.0交流系统用盘形悬式绝缘子耐污型绝缘子型号U70BP/146HU80BP/146HU100BP
6、/146HU120BP/146HU160BP/155HU210BP/170HU240BP/170HU300BP/190H公称直径D(mm)255255255255280280280320结构高度H(mm)146146146146155170170195公称爬电距离L(mm)400400400400450450450610连接标记(mm)1616161620202424额定机械破坏负荷(kN)7080100120160210240300逐个拉伸负荷试验(kN)3540506080105120150工频干耐受电压(kV)8080808085858590工频湿耐受电压(kV)454545455050
7、5055雷电冲击耐受电压(kV)110110110110125125125140冲击过电压击穿耐受电压(p.u.)2.82.82.82.82.82.82.82.8最小工频击穿耐受电压(kV)130130130130130130130130无线电干扰10kV;1MHz(V)5050505050505050可见电晕电压 脚/帽(kV)18/2218/2218/2218/2218/2218/2218/2218/22工频电弧试验0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA绝缘子单片重量(
8、kg)4.64.64.64.67.37.38.412.5 交流系统用盘形悬式绝缘子耐污型绝缘子型号U70BP/146HU80BP/146HU100BP/146HU120BP/146HU160BP/155HU210BP/170HU240BP/170HU300BP/195H公称直径D(mm)280280280280320320320380结构高度H(mm)146146146146155170170195公称爬电距离L(mm)450450450450550550550690连接标记(mm)1616161620202424额定机械破坏负荷(kN)7080100120160210240300逐个拉伸负荷
9、试验(kN)3540506080105120150工频干耐受电压(kV)85858585909090100工频湿耐受电压(kV)5050505055555560雷电冲击耐受电压(kV)125125125125140140140155冲击过电压击穿耐受电压(p.u.)2.82.82.82.82.82.82.82.8最小工频击穿耐受电压(kV)130130130130130130130130无线电干扰10kV;1MHz(V)5050505050505050可见电晕电压 脚/帽(kV)18/2218/2218/2218/2218/2218/2218/2218/22工频电弧试验0.12s/20kA0.
10、12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA绝缘子单片重量(kg)5.85.85.85.88.910.210.415.3交流系统用盘形悬式绝缘子耐污型绝缘子型号U70BP/146HU80BP/146HU100BP/146HU120BP/146HU160BP/155HU210BP/170H公称直径D(mm)320320320320330330结构高度H(mm)146146146146155170公称爬电距离L(mm)550550550550615615连接标记(mm)161616162020额定机械破坏负
11、荷(kN)7080100120160210逐个拉伸负荷试验(kN)3540506080105工频干耐受电压(kV)909090909090工频湿耐受电压(kV)555555555555雷电冲击耐受电压(kV)140140140140140140冲击过电压击穿耐受电压(p.u.)2.82.82.82.82.82.8最小工频击穿耐受电压(kV)130130130130130130无线电干扰10kV;1MHz(V)505050505050可见电晕电压 脚/帽(kV)18/2218/2218/2218/2218/2218/22工频电弧试验0.12s/20kA0.12s/20kA0.12s/20kA0.
12、12s/20kA0.12s/20kA0.12s/20kA绝缘子单片重量(kg)5.85.85.85.88.910.2交流系统用盘形悬式绝缘子双伞型绝缘子型号U70BP/146DU80BP/146DU100BP/146DU120BP/146DU160BP/155DU210BP/170DU240BP/170DU300BP/195D公称直径D(mm)280280280280340340340380结构高度H(mm)146146146146155170170195公称爬电距离L(mm)450450450450545545545635连接标记(mm)1616161620202424额定机械破坏负荷(kN
13、)7080100120160210240300逐个拉伸负荷试验(kN)3540506080105120150工频干耐受电压(kV)80808080858585100工频湿耐受电压(kV)4545454550505060雷电冲击耐受电压(kV)120120120120130130130150冲击过电压击穿耐受电压(p.u.)2.82.82.82.82.82.82.82.8最小工频击穿耐受电压(kV)130130130130130130130130无线电干扰10kV;1MHz(V)5050505050505050可见电晕电压 脚/帽(kV)18/2218/2218/2218/2218/2218/2
14、218/2218/22工频电弧试验0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA绝缘子单片重量(kg)5.85.85.85.88.910.210.415.3交流系统用盘形悬式绝缘子三伞型绝缘子型号U70BP/146TU80BP/146TU100BP/146TU120BP/146TU160BP/155TU210BP/170TU240BP/170TU300BP/195T公称直径D(mm)280280280280330330330380结构高度H(mm)14614614614615517
15、0170195公称爬电距离L(mm)450450450450550550550635连接标记(mm)1616161620202424额定机械破坏负荷(kN)7080100120160210240300逐个拉伸负荷试验(kN)3540506080105120150工频干耐受电压(kV)80808080858585100工频湿耐受电压(kV)4545454550505060雷电冲击耐受电压(kV)120120120120130130130150冲击过电压击穿耐受电压(p.u.)2.82.82.82.82.82.82.82.8最小工频击穿耐受电压(kV)130130130130130130130130无线电干扰10kV;1MHz(V)5050505050505050可见电晕电压 脚/帽(kV)18/2218/2218/2218/2218/2218/2218/2218/22工频电弧试验0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA0.12s/20kA绝缘子单片重量(kg)5.85.85.85.88.910.210.415.3仅供学习与交流,如有侵权请联系网站删除 谢谢6