资源描述
单击此处编辑母版标题样式,单击此处编辑母版文本样式,第二级,第三级,第四级,第五级,*,工场降温方案,2010,年,2,月,一 背景,单 位,09,年,10,年,11,年,3,月,4,月,5,月,2,月,3,月,4,月,5,月,2,月,3,月,4,月,5,月,热处理车间(新),热处理车间(老),铸造车间,锻造车间,FF,工场,联合厂房,制修工具车间,通过,点式,降温,热加工车间,环境有了改善,!,2010,年,FF,工场,开始降温了!,车间降温大日程计划,天,(,09.08,新热处理),降低温度,课题:,出风口风量不可调节,冷风直吹操作者,体感不好。,28.0,30.0,32.0,34.0,36.0,38.0,室外,32.0,30.5,30.0,30.0,33.0,32.5,34.3,34.8,34.2,32.5,29.0,29.0,29,29,29,30,29.5,AS701,组装线西南,32.8,32.5,30.2,29.5,33.0,32.5,36.3,36.9,36.0,35.0,32.0,31.5,29,31,32,30.5,30,12,科北休息区,32,32.0,29.5,30,32,31.5,35,35.5,35.3,33.5,32,31,30,30,31,30,29,MH703,线南,32,31,30,30,32,32,36,36.2,36,34,32,31,30,30,32,31,30,ASF041,线东南,31.5,33,30,31,32.5,32,36,36.7,36,34.5,31.5,32,30,30,31,30,29,GRF041,线西南,32,31.5,30,30.5,32,32,36.5,35.5,35,33.5,32.5,30,30,30,31,29.5,30,MHF041-3,线西南,32,33,31,32,34,31.5,36,36.7,36.5,35.5,31.5,31.8,30,31,32,30,28.5,MH801,线西北,32,32,31.5,30,32,32,36,36,35,34,32.5,30,29.5,31,31,30,29,3,4,5,6,7,10,12,13,14,15,21,22,25,26,27,28,31,温度测量时间,14,:,30,16,:,30,车间:,36.9,33,37,月平均,温度,32.1,室内温度高于,33,!,29,特高温区,警戒区,舒适区,适应区,高温作业,!,2009,年,8,月,FF,工场温度统计图,二 车间现状,结论:,FF,工场为高温作业场所,对,FF,工场降温,2,、解决措施,问题点:,高温作业,(工作岗位温度高于,33,),高温作业危害:,33-35,:精神疲惫,思维迟钝,烦躁不安;,35,以上:,心脏负担增加,容易肌肉痉挛、脱水、中暑。,1,、问题点,三 问题点、措施、目标,问题点、解决措施及目标,打造,舒适职场,,使,生产线员工,在比较舒适的环境中,工,作,,提高工作效率,保证产品质量,减少安全事故。,3,、设定目标,四,降温方案选择,各种降温方式评价,结论:岗位降温方式适于,FF,工场生产线降温。,降温方式,适应性,降温效果,体感,投资,运行费用,评价排序,评价,点式降温,3,岗位降温,1,整体降温,2,五 岗位降温方式调研,结论:,岗位降温有风冷空调降温和水冷空调降温两种方式。,风冷空调,冷风出口,风冷空调室外机,优点:,可单独控制,生产线降温,,利于降低运行成本;,不足:,室外机固定分散、占地面积大;,适应性:,适于,空气有污染、,人员不太集中的,小面积,生产线降温。,优点,:,与风冷降温相近,大面积降温时较风冷降温,效率高,室外占地面积集中,;,不足:,空调占用一部分场地;,适用性:,适于空气有污染、人员不太集中的,大面积,生产线降温。,2,、,水冷空调,岗位降温,(空调落地安装,),水冷空调,室外,冷却塔,1,、,风冷空调,岗位降温,(空调吊装),五 岗位降温方式调研,3,、风冷、水冷降温室内、室外机热交换形式区别,热风,室内机,冷凝器,室外机,蒸发器,制冷剂管路,风扇,风扇,冷风,车间,风冷降温原理,散热器,室外冷却塔,冷凝器,冷却水管路,风扇,风扇,冷风,车间,水冷降温原理,蓄水箱,蒸发器,冷却方式,机 型,冷却介质,散热效果,室外冷却,设施分布,风冷,分体机,:室外机制冷、依靠风扇散发热量,室内机散发冷风,两机室内、室外分开使用,一一对应。,室外空气,差,分散多处,占用场地大,水冷,一体机:,制冷、散热过程在室内机完成,散发的热量依靠冷却水带到室外冷却塔循环降温完成。,封闭循环水,好,集中一处,室内机,(4.0),(2.0),0.0,2.0,4.0,6.0,8.0,10.0,12.0,14.0,16.0,18.0,20.0,22.0,24.0,26.0,28.0,30.0,32.0,34.0,36.0,38.0,环境,生产线,温差,环境,26.2,23.7,23.5,30.7,29.7,33.1,33.3,34.3,33.5,31.2,29.4,29.4,29.6,30.3,生产线,27.1,25.1,24.9,30.1,29.1,32.2,31.8,33.1,31.5,32.2,30.1,29.3,28.5,29.0,温差,-0.9,-1.4,-1.4,0.6,0.6,0.9,1.5,1.2,2.0,-1.0,-0.7,0.1,1.1,1.3,6.17,6.27,7.1,7.10,7.16,7.22,7.28,8.4,8.5,8.13,8.19,8.28,9.1,9.11,33,高温分界线,室外,34.3,:,FF,工场,36,36.5,;,汽车零部件厂降温后,33.1,。,结论:采用降温措施后,高温天气时车间温度较室外温度低,2,。,1,、,2008,年测温数据,(唐山汽车零部件厂:,机加工生产线,岗位风冷),六 岗位降温效果调研,问题点,:,特高温天气车间温度超,33,,,原因,:测温点高于岗位温度,(,2009,年有,3,天室外温度接近,37,),33,高温分界线,零温差线,2,、,2009,年测温数据,(唐山汽车零部件厂:,机加工生产线,岗位风冷),六 岗位降温效果调研,温差,=,室外温度,-,车间温度,结论:特别高温天气(,37,)降温效果明显,,降温具有限制性,,车间温度高于,33,。,七 调研结果,结论:,岗位降温有风冷和水冷两种方式,各有优、缺点;,室外,34.8,时,车间温度,36.9,,,如采用岗位降温措施后,,,车间温度约有,4,温差降,低于,33,,符合公司打造舒适职场方针。,当室外温度,34,以上时,,降温约,2,左右,;,室内外温差越大,降温效果越明显;,岗位降温时,冷风直吹操作者,通过改善可提高体感;,室外低于,30,时降温效果不明显;,降温效果及规律:,八 降温方案比较、确定,方案,适用性,体感,大面积降温,效率,投资,安装,功率,运行,费用,室外机占地面积,评价,排序,综合,评价,水冷岗位降温,1,风冷岗位降温,2,方案评价,指标,区分,评价,结论,:选择水冷岗位降温作为,FF,工场降温方案。,冷却塔,位置,九 冷却塔安装位置选定,冷却塔,冷却塔,4*2.5*2.5m,场地,6.2*6.2m,MHF041-2,MHF041-3/MAF041,MH801/MH802,、,MHF041-1,、,GRF041,、,MH701,、,MH702,、,GR701/AS701,、,MH703/MA701,、,ASF041,安装数量,(台),支架安装,2,落地安装,11,安装方式选择原则,减轻对生产线布线、设备移动、生产线通道内作业的影响,设备检修方便、安全;,优先选择落地安装方式;,其次选择,支架安装;,十 空调安装方式选择,安装方式,生产线名称,落地安装:支架安装:,AS701,GR701,MA701,MH703,MH702,MH701,ASF041,GRF041,MAF041,MHF041-3,MHF041-2,MHF041-1,MH801,MH802,冷却塔,4*2.5m,十一 空调安装位置确定,共用,一台空调,共用,一台空调,场地,6.2*6.2m,冷风出口,2.5m,间距,风道,冷风出口,冷却塔,形式,FF,工场:,生产线,14,条、设备,340,台(套)、操作者,120,人,/,班,总体效果,:,车间整体温度较室外下降,2,左右,生产线岗位冷风出口冷风温度,23,,组装线出风口间距约,2.5m,生产线出风口间距,3.5m,,操作者可调节风口的风量、风向、高度满足体感需求。选用环保型,R407C,制冷剂。,十二 最终方案确定,厂家比较评价,厂家名称,报,价,(,万,元),设计,能力,特长,工程实例,评价排序,评价,天津市丰源冷暖系统工程有限公司(机械部汽车工业天津规划设计院),263,有,擅长设计和施工,TAAC,爱达克斯,丰田一工场,丰田锻造等,1,大连三洋空调机有限公司,336,有,具有空调的生产能力,无,2,天津岗谷钢机有限公司,380,无,有合作的设计施工单位,合作公司有工程实例,3,十三 厂家选择,结论:,天津市丰源冷暖系统工程有限公司为首选合作厂家。,十四 工期安排,区分,月 份,2,月,3,月,4,月,5,月,6,月,7,月,8,月,9,月,方案制定,设备审计,厂家设计,信息沟通,设备配套,安装、调试,运行、验收,效果确认,2.24,设备预审,3.22,设备审议,20,天,75,天,90,天,90,天,3,月底制造、生技、安环、生管、空调安装厂家就相关内容沟通、确认,,4,月,10,日合同签订。,工期进度,业务援助请求,原因:,专业外行,;,项目资金投入大;,本公司无先例;,资料来源:一部分实际调研,其它部分由合作商提供或查找资料。,援助内容:对合作商提供的方案进行确认,制冷参数选择是否合理,能否达到降温效果;,冷风出口布局的合理性;,设备选择的合理性;,空调布置的合理性;,其它更好的建议。,落地安装:支架安装:,AS701295924,GR70185616,MA70114309,MH70365516,MH70276018,MH70186018,ASF041194819,GRF04154814,MAF0411216,MHF041-323711,MHF0417-24513,MHF041-155015,MH8015258,MH8026186,冷却塔,4*2.5m,空调安装位置确定,共用,一台空调,共用,一台空调,场地,6.2*6.2m,ASF041,、,AS701,:冷风口,2.53m,间距,其它:冷风口,3.5m,间距或据实际需要确定,落地安装:支架安装:,AS701,GR701,MA701,MH703,MH702,MH701,ASF041,GRF041,MAF041,MHF041-3,MHF041-2,MHF041-1,MH801,MH802,冷却塔,4*2.5m,空调安装位置确定,共用,一台空调,共用,一台空调,场地,6.2*6.2m,ASF041,、,AS701,:冷风口,2.53m,间距,其它:冷风口,3.5m,间距或据实际需要确定,MH802,
展开阅读全文